Drives
Drives
-
Part
Part Number
Manufacturer
Description
-
- Danfoss 130B0056
- 130B0056
- Danfoss
- Adapter Plate, 338x279mm With the adapter plate you can replace a VLT 3000 by a FC drive without having to drill new holes for the FC drive. This makes it easy and fast to replace a VLT 3000, and as there will be no drilling there will be no swarf harming the electric components. It is possible to install one or two FC drives in the same place as one VLT 3000. Or one FC drive with a full size C Option (e.g. MCO305). The following VLT 3000 can be mounted on the Adapter Plate 130B0056: IP00/21: 220/380/500Volt VLT3002-3004 with no brake
-
- Danfoss 130B0058
- 130B0058
- Danfoss
- Adapter Plate, 415x279mm With the adapter plate you can replace a VLT 3000 by a FC drive without having to drill new holes for the FC drive. This makes it easy and fast to replace a VLT 3000, and as there will be no drilling there will be no swarf harming the electric components. It is possible to install one FC drive with or without C Option in the same place as one VLT 3000. The following VLT 3000 can be mounted on the Adapter Plate 130B0058: IP20: 220/380/500Volt VLT3002-3004 with brake, 380/500Volt VLT3006-3008 with no brake IP21: 220/380/500Volt VLT3002-3004 with brake, 380/500Volt VLT3006-3008 with no brake IP54: 220Volt VLT3002-3004 with no brake, 220Volt VLT3004 with brake, 380/500Volt VLT3002-3004 with brake, 380/500Volt VLT3002-3006 with no brake
-
- Danfoss 130B0183
- 130B0183
- Danfoss
- Adapter Plate, 395x90mm With the adapter plate you can replace a VLT 5/6/8000 by a FC drive without having to drill new holes for the FC drive. This makes it easy and fast to replace a VLT 5/6/8000, and as there will be no drilling there will be no swarf harming the electric components. The following VLT 5/6/8000 can be mounted on the Adapter Plate 130B0183: IP20 Book: 200-240Volt VLT5001-5003/VLT6002-6003, 380/500Volt VLT5001-5005, 380-460Volt VLT6002-6005
-
- Danfoss 130B0184
- 130B0184
- Danfoss
- Adapter Plate, 395x130mm With the adapter plate you can replace a VLT 5/6/8000 by a FC drive without having to drill new holes for the FC drive. This makes it easy and fast to replace a VLT 5/6/8000, and as there will be no drilling there will be no swarf harming the electric components. The following VLT 5/6/8000 can be mounted on the Adapter Plate 130B0184: IP20 Book: 200-240Volt VLT5004-5006/VLT6004-6005, 380/500Volt VLT5006-5011, 380-460Volt VLT6006-6011
-
- Danfoss 130B0185
- 130B0185
- Danfoss
- Adapter Plate, 395x220mm With the adapter plate you can replace a VLT 5/6/8000 by a FC drive without having to drill new holes for the FC drive. This makes it easy and fast to replace a VLT 5/6/8000, and as there will be no drilling there will be no swarf harming the electric components. The following VLT 5/6/8000 can be mounted on the Adapter Plate 130B0185: IP20 Compact:200-240Volt VLT5001-5006, 380/500Volt VLT5001-5011 IP20/NM1: 200-240Volt VLT6002-6005, 380/460Volt VLT6002-6011, 380-480Volt VLT8006-8011, 550-600Volt VLT 5001-5011, 525-690Volt VLT8002-8011
-
- Danfoss 130B1015
- 130B1015
- Danfoss
- Danfoss 7.5KW AC Drive
-
- Danfoss 130B1027
- 130B1027
- Danfoss
- AHF-DA-010-400-50-20-A VLT Advanced Harmonic Filter - AHF 010 The Danfoss Advanced Harmonic Filter is a compact passive harmonic filter specially designed to match the Danfoss frequency converters VLT AutomationDrive, VLT AQUA Drive and VLT HVAC/R Drives. The program offers two variants, AHF 005 and AHF 010.Connected in front of the Danfoss VLT frequency converter, the harmonic current distortion on the line is reduced to 5% or 10% at nominal load. Specifications: Line voltage: 380-415V Line frequency: 50Hz Nominal current: 10A THDi Less than 10% Cooling concept: Natural convection Efficiency: > 98 % Ambient temperature: 5-45 deg C Enclosure type: X1-V3 IP20 if Enclosure degree: IP20 (IP21 / NEMA 1 optional) Dimensions: Height: 322mm Width: 196mm Depth: 205mm Accessories: IP21 / NEMA1 Kit for AHF3 X1 : 175U3274 IP21/NEMA1 Kit for AHF3 X1 with capacitor disconnect option:175U5903 Backplate for AHF X1 : 130B3283
-
- Danfoss 130B1028
- 130B1028
- Danfoss
- Panel Through Mounting Kit, A5 Push-through frame kit for FC size A5 Contains mounting frame, seal, fastening material and assembly instructions.
-
- Danfoss 130B1046
- 130B1046
- Danfoss
- Panel Through Mounting Kit, B1 Push-through frame kit for FC size B1 Contains mounting frame, seal, Fastening material and assembly instructions.
-
- Danfoss 130B1047
- 130B1047
- Danfoss
- Panel Through Mounting Kit, B2 Push-through frame kit for FC size B2 Contains mounting frame, seal, Fastening material and assembly instructions.
-
- Danfoss 130B1048
- 130B1048
- Danfoss
- Panel Through Mounting Kit, C1 Push-through frame kit for FC size C1 Contains mounting frame, seal, Fastening material and assembly instructions.
-
- Danfoss 130B1049
- 130B1049
- Danfoss
- Panel Through Mounting Kit, C2 Push-through frame kit for FC size C2 Contains mounting frame, seal, Fastening material and assembly instructions
-
- Danfoss 130B1058
- 130B1058
- Danfoss
- AHF-DA-014-400-50-20-A VLT Advanced Harmonic Filter - AHF 010 The Danfoss Advanced Harmonic Filter is a compact passive harmonic filter specially designed to match the Danfoss frequency converters VLT AutomationDrive, VLT AQUA Drive and VLT HVAC/R Drives. The program offers two variants, AHF 005 and AHF 010.Connected in front of the Danfoss VLT frequency converter, the harmonic current distortion on the line is reduced to 5% or 10% at nominal load. Specifications: Line voltage: 380-415V Line frequency: 50Hz Nominal current: 14A THDi Less than 10% Cooling concept: Integrated fan with variable speed Efficiency: > 98 % Ambient temperature: 5-45 deg C Enclosure type: X1-V3 IP20 ef Enclosure degree: IP20 (IP21 / NEMA 1 optional) Dimensions: Height: 342mm Width: 196mm Depth: 205mm Accessories: IP21 / NEMA1 Kit for AHF3 X1 : 175U3274 IP21/NEMA1 Kit for AHF3 X1 with capacitor disconnect option:175U5903 Backplate for AHF X1 : 130B3283
-
- Danfoss 130B1078
- 130B1078
- Danfoss
- VLT Control Panel LCP 102, graphical LCP 102 - graphic control unit for FC100 / 200/300, degree of protection IP66
-
- Danfoss 130B1096
- 130B1096
- Danfoss
- Fan assembly 70x70x25 mm coated
-
- Danfoss 130B1097
- 130B1097
- Danfoss
- Fan assembly 80x80x25mm coated
-
- Danfoss 130B1098
- 130B1098
- Danfoss
- Back plate, IP55/Type12, A5 FC 300 back cover (galvanized steel) for the devices in IP21 / 55 Case size: A5
-
- Danfoss 130B1102
- 130B1102
- Danfoss
- VLT DeviceNet MCA 104, uncoated Robust, efficient data handling thanks to advanced Producer/Consumer technology. ODVA’s strong conformance testing policies ensure products are interoperable, and the AC-drive profile, supported using I/O instance 20/70.21/71, secures compatibility to existing systems.
-
- Danfoss 130B1103
- 130B1103
- Danfoss
- VLT CAN Open MCA 105, uncoated Standardized handling and interoperability for high flexibility and low costs. Fully equipped with both high-priority access to control and status of the drive (PDO Communication) and access to all parameters through acyclic data (SDO Communication). For interoperability the option has implemented the DSP402 AC-drive profile.
-
- Danfoss 130B1107
- 130B1107
- Danfoss
- VLT Control Panel LCP 102 Graphic operating unit LCP102 Illuminated graphic display with plain text. Supports all languages and characters. Quick menu for brief commissioning.Saving and copying parameter sets.Online help for each function
-
- Danfoss 130B1108
- 130B1108
- Danfoss
- VLT 24V DC Supply MCB 107, uncoated Connect an external DC supply to keep the control section and any installed option alive during power failure. Enables full operation of the LCP (including the parameter setting) and all installed options without connection to mains.
-
- Danfoss 130B1110
- 130B1110
- Danfoss
- VLT Relay Option MCB 105, uncoated Relay extension for FC 100 and FC 300. Extension with 3 additional load relays (changeover contacts), easy to retrofit thanks to modular technology. Max. Load 240V AC (resistive): 2 A Max. Load 240V AC (Cos Phi 0.4): 0.2 A Max. Load 24V DC (ohmic): 1 A Max. Load 24V DC (inductive): 0.1 A
-
- Danfoss 130B1112
- 130B1112
- Danfoss
- Sub-D9 Adapter kit, A1, A2, A3 SUB-D9 plug adapter for FC 100 and FC 300. Allows the use of SUB-D9 connectors at the Profibus DP interface.
-
- Danfoss 130B1113
- 130B1113
- Danfoss
- LCP Mounting Kit w/ graphical LCP102, 3m The kit includes graphical LCP, fasteners, 3m cable and gasket.
-
- Danfoss 130B1114
- 130B1114
- Danfoss
- LCP Mounting Kit w/ numerical LCP101, 3m The kit includes numerical LCP, fasteners, 3m cable and gasket.