Drives
Drives
-
Part
Part Number
Manufacturer
Description
-
- Danfoss 130B1202
- 130B1202
- Danfoss
- VLT DeviceNet MCA 104, coated MCA 104 - DeviceNet interface Option for FC300 and FC100 for mounting on the control card. Painted version
-
- Danfoss 130B1204 (AHF-DA-096-400-50-20-A)
- 130B1204 (AHF-DA-096-400-50-20-A)
- Danfoss
- VLT Advanced Harmonic Filter 010 The Danfoss Advanced Harmonic Filter is a compact passive harmonic filter specially designed to match the Danfoss frequency converters VLT AutomationDrive, VLT AQUA Drive and VLT HVAC/R Drives. The program offers two variants, AHF 005 and AHF 010.Connected in front of the Danfoss VLT frequency converter, the harmonic current distortion on the line is reduced to 5% or 10% at nominal load. Specifications: Line voltage: 380-415V Line frequency: 50Hz Nominal current: 96A THDi Less than 10% Cooling concept: Integrated fan with variable speed Efficiency: > 98 % Ambient temperature: 5-45 deg C Enclosure type: X5-V3 IP20 ef Enclosure degree: IP20 (IP21 / NEMA 1 optional) Dimensions: Height: 736mm Width: 418mm Depth: 333mm Accessories: IP21 / NEMA1 Kit for AHF3 X5 : 175U3278 IP21/NEMA1 Kit for AHF3 X5 with capacitor disconnect option:175U5907 Backplate for AHF X5/X6 : 130B3287
-
- Danfoss 130B1205
- 130B1205
- Danfoss
- VLT CAN Open MCA 105, coated CANopen interface for FC 300. Max. Baud rate 500 kBit / s. Support that DSP402 drive profile and PDO / SDO communication. Painted version for harsh environments. Easy to retrofit thanks to modular technology.
-
- Danfoss 130B1206
- 130B1206
- Danfoss
- VLT LonWorks MCA 108, coated Lonworks interface for FC 100. With modular technology Fieldbus option that can be easily retrofitted for the decentralized integration of the Frequency converter. The fieldbus option is based on the LonWorks Technology and corresponds to the LonMark Interoperability Guide. Painted version for harsh environments Hardware: Module technology for option slot A Transceiver: Free topology FTT 10 Transfer rate: 78kbit / s Protocol: Echelon LonTalk
-
- Danfoss 130B1208
- 130B1208
- Danfoss
- 1xMCB 107 24V DC coat w. mount. brackets Connect an external DC supply to keep the control section and any installed option alive during power failure. Enables full operation of the LCP (including the parameter setting) and all installed options without connection to mains.
-
- Danfoss 130B1210
- 130B1210
- Danfoss
- VLT Relay Option MCB 105, coated Relay extension for FC 100 and FC 300. Extension with 3 additional load relays (changeover contacts), easy to retrofit thanks to modular technology. Painted version for harsh environments, easy to retrofit thanks to modular technology. Max. Load 240V AC (resistive): 2 A Max. Load 240V AC (Cos Phi 0.4): 0.2 A Max. Load 24V DC (ohmic): 1 A Max. Load 24V DC (inductive): 0.1 A
-
- Danfoss 130B1212
- 130B1212
- Danfoss
- VLT General Purpose I/O MCB 101, ctd MCB 101 - Advanced I / O option Expands the number of freely programmable Control inputs and outputs around the following I / Os: - 3 digital inputs opto-decoupled 0 - 24 V. - 2 analog inputs 0 - 10 V. - 2 digital outputs NPN / PNP switchable 24 V - 1 analog output 0/4 - 20 mA with reinforced coating
-
- Danfoss 130B1227
- 130B1227
- Danfoss
- VLT Resolver Input MCB 103, coated Resolver extension for FC 300. Enables the connection of the following Resolver types: Input voltage: 4..8 Vrms Input frequency: 2.5..15 kHz Number of resolver poles: 2 or 4
-
- Danfoss 130B1243
- 130B1243
- Danfoss
- VLT Analog I/O Option MCB 109, coated I / O extension for FC 100, easy to retrofit thanks to modular technology. Analog inputs / outputs galvanically isolated. Expands the analog inputs / outputs by: 3 analog inputs: 0 ... 10V / Pt1000 / Ni1000 3 analog outputs: 0 ... 10V Time switch (RTC backup): lithium cell for 10 years
-
- Danfoss 130B1253
- 130B1253
- Danfoss
- VLT Position Controller MCO 351, ctd Extends the functional characteristics of the frequency converter in positioning applications - Direct positioning via fieldbus, relative positioning, absolute positioning and touch probe positioning - End stop handling (software and hardware) - Mechanical brake handling (programmable hold delay) Error handling - Jog speed / manual operation - None for programming, as it is pre-programmed Remember to order the Mounting kit if the above MCO option is required retrofitted. 130B7530 - Mounting kit for enclosures A2 and A3 130B7531 - Mounting kit for MCO Option, together with MCB 113, in enclosures A2 and A3 130B1413 - Mounting kit for enclosure B3 130B1414 - Mounting kit for MCO Option, together with MCB 113, in enclosure B3 130B7532 - Mounting kit for enclosure A5 130B7533 - Mounting kit for all enclosures B, C, D, E and F (B3 excepted) Danfoss MCO options are not sold without prior advice. Danfoss can offer help with programming / setting up MCO options. Contact Danfoss for advice and prices. Product group: R
-
- Danfoss 130B1260 (AHF-DB-381-400-50-20-A)
- 130B1260 (AHF-DB-381-400-50-20-A)
- Danfoss
- VLT Advanced Harmonic Filter 005 The Danfoss Advanced Harmonic Filter is a compact passive harmonic filter specially designed to match the Danfoss frequency converters VLT AutomationDrive, VLT AQUA Drive and VLT HVAC/R Drives. The program offers two variants, AHF 005 and AHF 010.Connected in front of the Danfoss VLT frequency converter, the harmonic current distortion on the line is reduced to 5% or 10% at nominal load. Specifications: Line voltage: 380-415V Line frequency: 50Hz Nominal current: 381A THDi less than 5% Cooling concept: Integrated fan with variable speed Efficiency: > 98 % Ambient temperature: 5-45 deg C Enclosure type: X8-V3 IP20 ef Enclosure degree: IP20 (IP21 / NEMA 1 optional) Dimensions: Height: 957mm Width: 468mm Depth: 515mm Accessories: IP21 / NEMA1 Kit for AHF3 X8 : 175U3282 IP21/NEMA1 Kit for AHF3 X8 with capacitor disconnect option:175U6100 Backplate for AHF X7/X8 : 130B3288
-
- Danfoss 130B1264
- 130B1264
- Danfoss
- VLT Extended Relay Card MCB 113, ctd Adds 7 digital inputs and 2 analog outputs for increased flexibility. 4 SPDT relays. Meets NAMUR recommendations. Galvanic isolation capability.
-
- Danfoss 130B1272
- 130B1272
- Danfoss
- VLT Sensor Input Card MCB 114, coated MCB 114 - PT100 / PT1000 option For FC100-FC200 and FC302, (Painted version). Enables the evaluation of up to 3 PT 100 or 3 PT 1000 sensors - Connection of 2 and 3 wire sensors - Automatic detection of the sensor type - Additional 4-20mA input
-
- Danfoss 130B1385
- 130B1385
- Danfoss
- VLT Profibus DP V1 MCA101 (5pcs)
-
- Danfoss 130B1413
- 130B1413
- Danfoss
- Mounting Kit f. C Option, 40mm, B3 Mounting kit for FC 302, C options, Case size B3 (40mm)
-
- Danfoss 130B1414
- 130B1414
- Danfoss
- Mounting Kit f. C Option , 60mm, B3 MCF 105 mounting kit for FC 302 C option B3 (60mm)
-
- Danfoss 130B1761 (AHF-DB-095-460-60-20-A)
- 130B1761 (AHF-DB-095-460-60-20-A)
- Danfoss
- VLT Advanced Harmonic Filter 005 The Danfoss Advanced Harmonic Filter is a compact passive harmonic filter specially designed to match the Danfoss frequency converters VLT AutomationDrive, VLT AQUA Drive and VLT HVAC/R Drives. The program offers two variants, AHF 005 and AHF 010.Connected in front of the Danfoss VLT frequency converter, the harmonic current distortion on the line is reduced to 5% or 10% at nominal load. Specifications: Line voltage: 440-480V Line frequency: 60Hz Nominal current: 95A THDi less than 5% Cooling concept: Integrated fan with variable speed Efficiency: > 98 % Ambient temperature: 5-45 deg C Enclosure type: X5-V3 IP20 ef Enclosure degree: IP20 (IP21 / NEMA 1 optional) Dimensions: Height: 736mm Width: 418mm Depth: 333mm Accessories: IP21 / NEMA1 Kit for AHF3 X5 : 175U3278 IP21/NEMA1 Kit for AHF3 X5 with capacitor disconnect option:175U5907 Backplate for AHF X5/X6 : 130B3287
-
- Danfoss 130B1894
- 130B1894
- Danfoss
- Current transducer card, 500V frame C1/C3/H7/I7
-
- Danfoss 130B1897
- 130B1897
- Danfoss
- Current transducer card, 500V frame C2/C4/H7
-
- Danfoss 130B2235
- 130B2235
- Danfoss
- FC Option DV/DT Filter 430A, IP00
-
- Danfoss 130B2236
- 130B2236
- Danfoss
- FC Option DV/DT Filter 530A, IP00
-
- Danfoss 130B2238
- 130B2238
- Danfoss
- FC Option DV/DT Filter 430A, IP20
-
- Danfoss 130B2239
- 130B2239
- Danfoss
- FC Option DV/DT Filter 530A, IP20
-
- Danfoss 130B2241
- 130B2241
- Danfoss
- FC Option Sine-wave Filter 430A, IP00
-
- Danfoss 130B2242
- 130B2242
- Danfoss
- FC Option Sine-wave Filter 530A, IP00