Drives
Drives
-
Part
Part Number
Manufacturer
Description
-
- Danfoss 131B0455 (FC-302P3K0T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- 131B0455 (FC-302P3K0T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC 300 3.0 KW / 4.0 HP, 380 - 500 VAC, IP20
-
- Danfoss 131B0456 (FC-302P4K0T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- 131B0456 (FC-302P4K0T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P4K0) 4.0 KW / 5.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0457 (FC-302P5K5T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- 131B0457 (FC-302P5K5T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P5K5) 5.5 KW / 7.5 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A3 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0457 (FC-302P5K5T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- 131B0457 (FC-302P5K5T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC 300 5.5 KW / 7.5 HP, 380 - 500 VAC, IP20
-
- Danfoss 131B0458 (FC-302P7K5T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- 131B0458 (FC-302P7K5T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P7K5) 7.5 KW / 10 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A3 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0459 (FC-302PK37T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- 131B0459 (FC-302PK37T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (PK37) 0.37 KW / 0.50 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0460 (FC-302PK55T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- 131B0460 (FC-302PK55T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302 0.55 KW / 0.75 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0461 (FC-302PK75T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- 131B0461 (FC-302PK75T5E20H1XGXXXXSXXXXA0BXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (PK75) 0.75 KW / 1.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0462 (FC-302PK75T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- 131B0462 (FC-302PK75T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (PK75) 0.75 KW / 1.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0463 (FC-302P1K1T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- 131B0463 (FC-302P1K1T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P1K1) 1.1 KW / 1.5 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0464 (FC-302P2K2T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- 131B0464 (FC-302P2K2T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0465 (FC-302P3K0T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- 131B0465 (FC-302P3K0T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P3K0) 3.0 KW / 4.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0466 (FC-302P4K0T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- 131B0466 (FC-302P4K0T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P4K0) 4.0 KW / 5.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0467 (FC-302P5K5T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- 131B0467 (FC-302P5K5T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P5K5) 5.5 KW / 7.5 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A3 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0468 (FC-302P7K5T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- 131B0468 (FC-302P7K5T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P7K5) 7.5 KW / 10 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A3 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0469 (FC-302PK37T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- 131B0469 (FC-302PK37T5E20H1XGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (PK37) 0.37 KW / 0.50 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0471 (FC-302P1K1T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- 131B0471 (FC-302P1K1T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P1K1) 1.1 KW / 1.5 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0472 (FC-302P1K5T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- 131B0472 (FC-302P1K5T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P1K5) 1.5 KW / 2.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0473 (FC-302P2K2T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- 131B0473 (FC-302P2K2T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0474 (FC-302P3K0T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- 131B0474 (FC-302P3K0T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P3K0) 3.0 KW / 4.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0475 (FC-302P4K0T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- 131B0475 (FC-302P4K0T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P4K0) 4.0 KW / 5.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0476 (FC-302P5K5T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- 131B0476 (FC-302P5K5T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P5K5) 5.5 KW / 7.5 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A3 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0477 (FC-302P7K5T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- 131B0477 (FC-302P7K5T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P7K5) 7.5 KW / 10 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A3 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0478 (FC-302PK37T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- 131B0478 (FC-302PK37T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (PK37) 0.37 KW / 0.50 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0479 (FC-302PK75T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- 131B0479 (FC-302PK75T5E20H1BGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (PK75) 0.75 KW / 1.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code