Drives
Drives
-
Part
Part Number
Manufacturer
Description
-
- Danfoss 131B0496
- 131B0496
- Danfoss
- FC-302P1K5T5E20H1BGXXXXSXXXXAXBXCXXXXD0 Frequency converter FC-302P1K5T5E20H1BGXXXXSXXXXAXBXCXXXXD0 VLT AutomationDrive FC-302 (P1K5) 1.5 KW / 2.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 No A Option, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0497
- 131B0497
- Danfoss
- FC-302PK37T5E20H1XXXXXXSXXXXA0BXCXXXXDX Frequency converter FC-302PK37T5E20H1XXXXXXSXXXXA0BXCXXXXDX VLT AutomationDrive FC-302 (PK37) 0.37 KW / 0.50 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0498
- 131B0498
- Danfoss
- FC-302PK37T5E20H1XXXXXXSXXXXA0BXCXXXXD0 Frequency converter FC-302PK37T5E20H1XXXXXXSXXXXA0BXCXXXXD0 VLT AutomationDrive FC-302 (PK37) 0.37 KW / 0.50 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0499
- 131B0499
- Danfoss
- FC-302PK37T5E20H1XXXXXXSXXXXA4BXCXXXXDX Frequency converter FC-302PK37T5E20H1XXXXXXSXXXXA4BXCXXXXDX VLT AutomationDrive FC-302 (PK37) 0.37 KW / 0.50 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 DeviceNet MCA 104, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0500
- 131B0500
- Danfoss
- FC-302PK37T5E20H1XXXXXXSXXXXAXBXCXXXXD0 Frequency converter FC-302PK37T5E20H1XXXXXXSXXXXAXBXCXXXXD0 VLT AutomationDrive FC-302 (PK37) 0.37 KW / 0.50 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 No A Option, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0502
- 131B0502
- Danfoss
- FC-302PK55T5E20H1XXXXXXSXXXXA4BXCXXXXDX Frequency converter FC-302PK55T5E20H1XXXXXXSXXXXA4BXCXXXXDX VLT AutomationDrive FC-302 0.55 KW / 0.75 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 DeviceNet MCA 104, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0503
- 131B0503
- Danfoss
- FC-302PK55T5E20H1XXXXXXSXXXXA0BXCXXXXD0 Frequency converter FC-302PK55T5E20H1XXXXXXSXXXXA0BXCXXXXD0 VLT AutomationDrive FC-302 0.55 KW / 0.75 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0504
- 131B0504
- Danfoss
- FC-302PK55T5E20H1XXXXXXSXXXXA0BXCXXXXDX Frequency converter FC-302PK55T5E20H1XXXXXXSXXXXA0BXCXXXXDX VLT AutomationDrive FC-302 0.55 KW / 0.75 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0507
- 131B0507
- Danfoss
- FC-302PK75T5E20H1BXXXXXSXXXXA0BXCXXXXDX Frequency converter FC-302PK75T5E20H1BXXXXXSXXXXA0BXCXXXXDX VLT AutomationDrive FC-302 (PK75) 0.75 KW / 1.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0508
- 131B0508
- Danfoss
- FC-302PK75T5E20H1BXXXXXSXXXXA0BXCXXXXD0 Frequency converter FC-302PK75T5E20H1BXXXXXSXXXXA0BXCXXXXD0 VLT AutomationDrive FC-302 (PK75) 0.75 KW / 1.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0509
- 131B0509
- Danfoss
- FC-302PK75T5E20H1XXXXXXSXXXXA0BXCXXXXDX Frequency converter FC-302PK75T5E20H1XXXXXXSXXXXA0BXCXXXXDX VLT AutomationDrive FC-302 (PK75) 0.75 KW / 1.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0510
- 131B0510
- Danfoss
- FC-302PK75T5E20H1XXXXXXSXXXXA0BXCXXXXD0 Frequency converter FC-302PK75T5E20H1XXXXXXSXXXXA0BXCXXXXD0 VLT AutomationDrive FC-302 (PK75) 0.75 KW / 1.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0511
- 131B0511
- Danfoss
- FC-302PK75T5E20H1XXXXXXSXXXXA4BXCXXXXDX Frequency converter FC-302PK75T5E20H1XXXXXXSXXXXA4BXCXXXXDX VLT AutomationDrive FC-302 (PK75) 0.75 KW / 1.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 DeviceNet MCA 104, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0513
- 131B0513
- Danfoss
- FC-302P1K1T5E20H1XXXXXXSXXXXA4BXCXXXXDX Frequency converter FC-302P1K1T5E20H1XXXXXXSXXXXA4BXCXXXXDX VLT AutomationDrive FC-302 (P1K1) 1.1 KW / 1.5 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 DeviceNet MCA 104, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0514
- 131B0514
- Danfoss
- FC-302P1K1T5E20H1XXXXXXSXXXXA0BXCXXXXDX Frequency converter FC-302P1K1T5E20H1XXXXXXSXXXXA0BXCXXXXDX VLT AutomationDrive FC-302 (P1K1) 1.1 KW / 1.5 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0515
- 131B0515
- Danfoss
- FC-302P1K1T5E20H1XXXXXXSXXXXA0BXCXXXXD0 Frequency converter FC-302P1K1T5E20H1XXXXXXSXXXXA0BXCXXXXD0 VLT AutomationDrive FC-302 (P1K1) 1.1 KW / 1.5 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0517
- 131B0517
- Danfoss
- FC-302P1K5T5E20H1XXXXXXSXXXXA0BXCXXXXD0 Frequency converter FC-302P1K5T5E20H1XXXXXXSXXXXA0BXCXXXXD0 VLT AutomationDrive FC-302 (P1K5) 1.5 KW / 2.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0518
- 131B0518
- Danfoss
- FC-302P1K5T5E20H1XXXXXXSXXXXA0BXCXXXXDX Frequency converter FC-302P1K5T5E20H1XXXXXXSXXXXA0BXCXXXXDX VLT AutomationDrive FC-302 (P1K5) 1.5 KW / 2.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0519
- 131B0519
- Danfoss
- FC-302P1K5T5E20H1XXXXXXSXXXXA4BXCXXXXDX Frequency converter FC-302P1K5T5E20H1XXXXXXSXXXXA4BXCXXXXDX VLT AutomationDrive FC-302 (P1K5) 1.5 KW / 2.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 DeviceNet MCA 104, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0521
- 131B0521
- Danfoss
- FC-302P2K2T5E20H1XXXXXXSXXXXA0BXCXXXXDX Frequency converter FC-302P2K2T5E20H1XXXXXXSXXXXA0BXCXXXXDX VLT AutomationDrive FC-302 (P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0522
- 131B0522
- Danfoss
- FC-302P2K2T5E20H1XXXXXXSXXXXA0BXCXXXXD0 Frequency converter FC-302P2K2T5E20H1XXXXXXSXXXXA0BXCXXXXD0 VLT AutomationDrive FC-302 (P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0523
- 131B0523
- Danfoss
- FC-302P2K2T5E20H1XXXXXXSXXXXAXBXCXXXXD0 Frequency converter FC-302P2K2T5E20H1XXXXXXSXXXXAXBXCXXXXD0 VLT AutomationDrive FC-302 (P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 No A Option, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B0524
- 131B0524
- Danfoss
- FC-302P2K2T5E20H1XXXXXXSXXXXA4BXCXXXXDX Frequency converter FC-302P2K2T5E20H1XXXXXXSXXXXA4BXCXXXXDX VLT AutomationDrive FC-302 (P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 DeviceNet MCA 104, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0525
- 131B0525
- Danfoss
- FC-302P3K0T5E20H1XXXXXXSXXXXA0BXCXXXXDX Frequency converter FC-302P3K0T5E20H1XXXXXXSXXXXA0BXCXXXXDX VLT AutomationDrive FC-302 (P3K0) 3.0 KW / 4.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B0526
- 131B0526
- Danfoss
- FC-302P3K0T5E20H1XXXXXXSXXXXA0BXCXXXXD0 Frequency converter FC-302P3K0T5E20H1XXXXXXSXXXXA0BXCXXXXD0 VLT AutomationDrive FC-302 (P3K0) 3.0 KW / 4.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code