- Danfoss 131B5742 (FC-301PK75T4Z20H2TXXXXXSXXXXA0BXCXXXXDX)
- 131B5742 (FC-301PK75T4Z20H2TXXXXXSXXXXA0BXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-301, (PK75) 0.75 KW / 1.0 HP, Three phase, 380 - 480 VAC, IP20 / Chassis A1 Frame RFI Filter Safe Stop No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A1 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B5745 (FC-301P1K5T4Z20H2UXXXXXSXXXXA0BXCXXXXDX)
- 131B5745 (FC-301P1K5T4Z20H2UXXXXXSXXXXA0BXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-301, (P1K5) 1.5 KW / 2.0 HP, Three phase, 380 - 480 VAC, IP20 / Chassis A1 Frame RFI Filter Brake chopper + Safe stop No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A1 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B5792 (FC-302P15KT5P55H1XGX1XXSXXXXAXBXCXXXXDX)
- 131B5792 (FC-302P15KT5P55H1XGX1XXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P15K) 15 KW / 20 HP, Three phase, 380 - 500 VAC, IP55 / Type12 Backplate (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, Mains Disconnect Latest release standard software. Frame: B1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B5799 (FC-102P30KT4E21H1XGXXXXSXXXXAXBXCXXXXDX)
- 131B5799 (FC-102P30KT4E21H1XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P30K) 30 KW / 40 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: B2 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131B5837 (FC-102P15KT4E21H1XGXXXXSXXXXAXBXCXXXXDX)
- 131B5837 (FC-102P15KT4E21H1XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P15K) 15 KW / 20 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: B1 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131B5838 (FC-102P18KT4E21H1XGXXXXSXXXXAXBXCXXXXDX)
- 131B5838 (FC-102P18KT4E21H1XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P18K) 18.5 KW / 25 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: B1 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131B5839 (FC-102P22KT4E21H1XGXXXXSXXXXAXBXCXXXXDX)
- 131B5839 (FC-102P22KT4E21H1XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P22K) 22 KW / 30 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: B2 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131B5843 (FC-301P75KT4E66H1XGXXXXSXXXXA0BXCXXXXDX)
- 131B5843 (FC-301P75KT4E66H1XGXXXXSXXXXA0BXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-301, (P75K) 75 KW / 100 HP, Three phase, 380 - 480 VAC, (E66) IP66 / NEMA 4X (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C2 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B5929 (FC-302P90KT5E21H4XGXXXXSXXXXAXBXCXXXXDX)
- 131B5929 (FC-302P90KT5E21H4XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P90K) 90 KW / 125 HP, Three phase, 380 - 500 VAC, IP21 / Type 1 RFI class A1 (C2) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: D1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B5932 (FC-302P160T5E21H4XGXXXXSXXXXAXBXCXXXXDX)
- 131B5932 (FC-302P160T5E21H4XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P160) 160 KW / 250 HP, Three phase, 380 - 500 VAC, IP21 / Type 1 RFI class A1 (C2) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: D2 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B5936 (FC-302P90KT5E21H4XGXXXXSXXXXA0BXCXXXXDX)
- 131B5936 (FC-302P90KT5E21H4XGXXXXSXXXXA0BXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P90K) 90 KW / 125 HP, Three phase, 380 - 500 VAC, IP21 / Type 1 RFI class A1 (C2) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: D1 PROFIBUS DP MCA 101, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B5945 (FC-102P30KT4E20H1XGXXXXSXXXXAXBXCXXXXDX)
- 131B5945 (FC-102P30KT4E20H1XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P30K) 30 KW / 40 HP, Three phase, 380 - 480 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: B4 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131B5946 (FC-302P22KT5E20H1)
- 131B5946 (FC-302P22KT5E20H1)
- Danfoss
- VLT AutomationDrive FC 302 Flexible, modular design for versatile control
-
- Danfoss 131B5946 (FC-302P22KT5E20H1XGXXXXSXXXXAXBXCXXXXDX)
- 131B5946 (FC-302P22KT5E20H1XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P22K) 22 KW / 30 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: B4 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B5965 (FC-302P7K5T2E55H1BGXXXXSXXXXAXBXCXXXXDX)
- 131B5965 (FC-302P7K5T2E55H1BGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P7K5) 7.5 KW / 10 HP, Three phase, 200 - 240 VAC, IP55 / Type 12 (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: B1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B5977 (FC-302P30KT5E21H1BGXXXXSXXXXAXBXCXXXXDX)
- 131B5977 (FC-302P30KT5E21H1BGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P30K) 30 KW / 40 HP, Three phase, 380 - 500 VAC, IP21 / Type 1 (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B5978 (FC-302P37KT5E21H1BGXXXXSXXXXAXBXCXXXXDX)
- 131B5978 (FC-302P37KT5E21H1BGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P37K) 37 KW / 50 HP, Three phase, 380 - 500 VAC, IP21 / Type 1 (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B6025 (FC-302P22KT2E21H1XGXXXXSXXXXAXBXCXXXXDX)
- 131B6025 (FC-302P22KT2E21H1XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P22K) 22 KW / 30 HP, Three phase, 200 - 240 VAC, IP21 / Type 1 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B6033 (FC-302P55KT5E21H1BGXXXXSXXXXAXBXCXXXXDX)
- 131B6033 (FC-302P55KT5E21H1BGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P55K) 55 KW / 75 HP, Three phase, 380 - 500 VAC, IP21 / Type 1 (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C2 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B6035 (FC-302P55KT5E55H2XGXXXXSXXXXAXBXCXXXXDX)
- 131B6035 (FC-302P55KT5E55H2XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P55K) 55 KW / 75 HP, Three phase, 380 - 500 VAC, IP55 / Type 12 RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C2 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B6039 (FC-302P75KT5E55H2XGXXXXSXXXXAXBXCXXXXDX)
- 131B6039 (FC-302P75KT5E55H2XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P75K) 75 KW / 100 HP, Three phase, 380 - 500 VAC, IP55 / Type 12 RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C2 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B6083 (FC-301P30KT4E21H2XXXXXXSXXXXAXBXCXXXXDX)
- 131B6083 (FC-301P30KT4E21H2XXXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-301, (P30K) 30 KW / 40 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 RFI Filter No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B6084 (FC-301P30KT4E21H2XGXXXXSXXXXAXBXCXXXXDX)
- 131B6084 (FC-301P30KT4E21H2XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-301, (P30K) 30 KW / 40 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B6085 (FC-301P30KT4E21H1XGCXXXSXXXXAXBXCXXXXDX)
- 131B6085 (FC-301P30KT4E21H1XGCXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-301, (P30K) 30 KW / 40 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Coated PCB, No Mains Option Latest release standard software. Frame: C1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B6086 (FC-301P30KT4E21H2XGCXXXSXXXXAXBXCXXXXDX)
- 131B6086 (FC-301P30KT4E21H2XGCXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-301, (P30K) 30 KW / 40 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 RFI Filter No brake chopper Graphical Local Control Panel Coated PCB, No Mains Option Latest release standard software. Frame: C1 No A Option, No B Option No C1 option, No D option Other options according to Model code