Drives
Drives
-
Part
Part Number
Manufacturer
Description
-
- Danfoss 131B9045 (FC-202P37KT4E55H2XGXXXXSXXXXAXBXCXXXXDX)
- 131B9045 (FC-202P37KT4E55H2XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P37K) 37 KW / 50 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9046 (FC-202P37KT4E55H1XGXXXXSXXXXAXBXCXXXXDX)
- 131B9046 (FC-202P37KT4E55H1XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P37K) 37 KW / 50 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9051 (FC-202P45KT4E21H2XGCXXXSXXXXAXBXCXXXXDX)
- 131B9051 (FC-202P45KT4E21H2XGCXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P45K) 45 KW / 60 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 RFI Filter No brake chopper Graphical Local Control Panel Coated PCB, No Mains Option Latest release standard software. Frame: C1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9052 (FC-202P45KT4E55H2XGXXXXSXXXXAXBXCXXXXDX)
- 131B9052 (FC-202P45KT4E55H2XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P45K) 45 KW / 60 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9053 (FC-202P45KT4E55H1XGXXXXSXXXXAXBXCXXXXDX)
- 131B9053 (FC-202P45KT4E55H1XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P45K) 45 KW / 60 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9056 (FC-202P55KT4E21H2XGXXXXSXXXXAXBXCXXXXDX)
- 131B9056 (FC-202P55KT4E21H2XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P55K) 55 KW / 75 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9064 (FC-202P55KT4E55H1XGXXXXSXXXXAXBXCXXXXDX)
- 131B9064 (FC-202P55KT4E55H1XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P55K) 55 KW / 75 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9065 (FC-202P75KT4E21H2XXXXXXSXXXXAXBXCXXXXDX)
- 131B9065 (FC-202P75KT4E21H2XXXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P75K) 75 KW / 100 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 RFI Filter No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C2 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9066 (FC-202P75KT4E21H2XGXXXXSXXXXAXBXCXXXXDX)
- 131B9066 (FC-202P75KT4E21H2XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P75K) 75 KW / 100 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C2 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9067 (FC-202P75KT4E21H3XGXXXXSXXXXAXBXCXXXXDX)
- 131B9067 (FC-202P75KT4E21H3XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P75K) 75 KW / 100 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 (H3) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C2 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9069 (FC-202P75KT4E21H2XGCXXXSXXXXAXBXCXXXXDX)
- 131B9069 (FC-202P75KT4E21H2XGCXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P75K) 75 KW / 100 HP, Three phase, 380 - 480 VAC, IP21
-
- Danfoss 131B9070 (FC-202P75KT4E55H2XGXXXXSXXXXAXBXCXXXXDX)
- 131B9070 (FC-202P75KT4E55H2XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P75K) 75 KW / 100 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C2 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9073 (FC-202P90KT4E21H2XGXXXXSXXXXAXBXCXXXXDX)
- 131B9073 (FC-202P90KT4E21H2XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P90K) 90 KW / 125 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C2 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9077 (FC-202P90KT4E55H2XGXXXXSXXXXAXBXCXXXXDX)
- 131B9077 (FC-202P90KT4E55H2XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P90K) 90 KW / 125 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C2 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9080 (FC-202PK25T2E20H2XGXXXXSXXXXAXBXCXXXXDX)
- 131B9080 (FC-202PK25T2E20H2XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (PK25) 0.25 KW / 0.33 HP, Three phase, 200 - 240 VAC, (E20) IP20 / Chassis RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9089 (FC-302PK55T5E20H1BXXXXXSXXXXAXBXCXXXXD0)
- 131B9089 (FC-302PK55T5E20H1BXXXXXSXXXXAXBXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302 0.55 KW / 0.75 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 No A Option, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B9243 (FC-302P75KT5E21H1XGXXXXSXXXXA0BXCXXXXD0)
- 131B9243 (FC-302P75KT5E21H1XGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P75K) 75 KW / 100 HP, Three phase, 380 - 500 VAC, IP21 / Type 1 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B9245 (FC-302P75KT5E55H1XGXXXXSXXXXA0BXCXXXXD0)
- 131B9245 (FC-302P75KT5E55H1XGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P75K) 75 KW / 100 HP, Three phase, 380 - 500 VAC, IP55 / Type 12 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C2 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131B9269 (FC-202P15KT2E55H2XGXXXXSXXXXAXBXCXXXXDX)
- 131B9269 (FC-202P15KT2E55H2XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P15K) 15 KW / 20 HP, Three phase, 200 - 240 VAC, IP55 / Type 12 RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: B2 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131B9280 (FC-102P75KT4E21H1XGXXXXSXXXXAXBXCXXXXDX)
- 131B9280 (FC-102P75KT4E21H1XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P75K) 75 KW / 100 HP, Three phase, 380 - 480 VAC, IP21 / Type 1 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C2 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131B9296 (FC-102P1K1T4E66H3XGXXXXSXXXXAXBXCXXXXDX)
- 131B9296 (FC-102P1K1T4E66H3XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P1K1) 1.1 KW / 1.5 HP, Three phase, 380 - 480 VAC, (E66) IP66 / NEMA 4X (H3) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A5 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131B9297 (FC-102P2K2T4E66H3XGXXXXSXXXXAXBXCXXXXDX)
- 131B9297 (FC-102P2K2T4E66H3XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 480 VAC, (E66) IP66 / NEMA 4X (H3) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A5 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131B9298 (FC-102P3K0T4E66H3XGXXXXSXXXXAXBXCXXXXDX)
- 131B9298 (FC-102P3K0T4E66H3XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P3K0) 3.0 KW / 4.0 HP, Three phase, 380 - 480 VAC, (E66) IP66 / NEMA 4X (H3) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A5 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131B9299 (FC-102P4K0T4E66H3XGXXXXSXXXXAXBXCXXXXDX)
- 131B9299 (FC-102P4K0T4E66H3XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P4K0) 4.0 KW / 5.0 HP, Three phase, 380 - 480 VAC, (E66) IP66 / NEMA 4X (H3) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A5 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131B9300 (FC-102P5K5T4E66H3XGXXXXSXXXXAXBXCXXXXDX)
- 131B9300 (FC-102P5K5T4E66H3XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P5K5) 5.5 KW / 7.5 HP, Three phase, 380 - 480 VAC, (E66) IP66 / NEMA 4X (H3) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A5 No A Option, No B Option No C1 option, No D option Other options according to Model Code