Drives
Drives
-
Part
Part Number
Manufacturer
Description
-
- Danfoss 131U0491 (FC-302P5K5T5E20H2BGXXXXSXXXXA0B2CXXXXD0)
- 131U0491 (FC-302P5K5T5E20H2BGXXXXSXXXXA0B2CXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P5K5) 5.5 KW / 7.5 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis RFI Filter Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A3 PROFIBUS DP MCA 101, MCB-112 PTC Therm. Card No C1 option, MCB-107 24V DC backup ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db] Other options according to Model code
-
- Danfoss 131U0722 (FC-302P2K2T5E20H1XGXXXXSXXXXALBXCXXXXDX)
- 131U0722 (FC-302P2K2T5E20H1XGXXXXSXXXXALBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFINET MCA 120, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131U0728 (FC-302P30KT5E20H1XGXXXXSXXXXALBXCXXXXDX)
- 131U0728 (FC-302P30KT5E20H1XGXXXXSXXXXALBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P30K) 30 KW / 40 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: B4 PROFINET MCA 120, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131U0805 (FC-302P1K5T5E20H1XGXXXXSXXXXALBXCXXXXDX)
- 131U0805 (FC-302P1K5T5E20H1XGXXXXSXXXXALBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P1K5) 1.5 KW / 2.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFINET MCA 120, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131U0964 (FC-102P2K2T4Z55H3XGXXOXSXXXXAXBXCXXXXDX)
- 131U0964 (FC-102P2K2T4Z55H3XGXXOXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 A4 Frame (H3) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A4 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131U1245 (FC-202P15KT4E55H1TGCXXXSXXXXAXBXCXXXXDX)
- 131U1245 (FC-202P15KT4E55H1TGCXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P15K) 15 KW / 20 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 (H1) RFI Class A1/B (C1) Safe Stop Graphical Local Control Panel Coated PCB, No Mains Option Latest release standard software. Frame: B1 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131U1521 (FC-302P3K0T5Z55H1XGXXXXSXXXXAXBXCXXXXDX)
- 131U1521 (FC-302P3K0T5Z55H1XGXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P3K0) 3.0 KW / 4.0 HP, Three phase, 380 - 500 VAC, IP55 / Type 12 A4 Frame (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A4 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131U1802 (FC-302PK37T2E20H1XXXXXXSXXXXA4BXCXXXXDX)
- 131U1802 (FC-302PK37T2E20H1XXXXXXSXXXXA4BXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (PK37) 0.37 KW / 0.50 HP, Three phase, 200 - 240 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 DeviceNet MCA 104, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131U2144 (FC-302P3K0T5E55H1XGCXXXSXXXXALBXCXXXXD0)
- 131U2144 (FC-302P3K0T5E55H1XGCXXXSXXXXALBXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P3K0) 3.0 KW / 4.0 HP, Three phase, 380 - 500 VAC, IP55 / Type 12 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Coated PCB, No Mains Option Latest release standard software. Frame: A5 PROFINET MCA 120, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131U2253 (FC-102P1K1T4Z55H3XGX1XXSXXXXAXBXCXXXXDX)
- 131U2253 (FC-102P1K1T4Z55H3XGX1XXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P1K1) 1.1 KW / 1.5 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 A4 Frame (H3) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, Mains Disconnect Latest release standard software. Frame: A4 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131U2254 (FC-102P1K5T4Z55H3XGX1XXSXXXXAXBXCXXXXDX)
- 131U2254 (FC-102P1K5T4Z55H3XGX1XXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P1K5) 1.5 KW / 2.0 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 A4 Frame (H3) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, Mains Disconnect Latest release standard software. Frame: A4 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131U2255 (FC-102P2K2T4Z55H3XGX1XXSXXXXAXBXCXXXXDX)
- 131U2255 (FC-102P2K2T4Z55H3XGX1XXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 A4 Frame (H3) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, Mains Disconnect Latest release standard software. Frame: A4 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131U2256 (FC-102P3K0T4Z55H3XGX1XXSXXXXAXBXCXXXXDX)
- 131U2256 (FC-102P3K0T4Z55H3XGX1XXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P3K0) 3.0 KW / 4.0 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 A4 Frame (H3) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, Mains Disconnect Latest release standard software. Frame: A4 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131U2257 (FC-102P4K0T4Z55H3XGX1XXSXXXXAXBXCXXXXDX)
- 131U2257 (FC-102P4K0T4Z55H3XGX1XXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P4K0) 4.0 KW / 5.0 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 A4 Frame (H3) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, Mains Disconnect Latest release standard software. Frame: A4 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131U2466 (FC-102P30KT4E20H1TXXXXXSXXXXAXBXCXXXXDX)
- 131U2466 (FC-102P30KT4E20H1TXXXXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P30K) 30 KW / 40 HP, Three phase, 380 - 480 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Safe Stop No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: B4 No A Option, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131U2752 (FC-302P2K2T5E20H1XGCXXXSXXXXALBXCXXXXD0)
- 131U2752 (FC-302P2K2T5E20H1XGCXXXSXXXXALBXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFINET MCA 120, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131U2753 (FC-302P3K0T5E20H1XGCXXXSXXXXALBXCXXXXD0)
- 131U2753 (FC-302P3K0T5E20H1XGCXXXSXXXXALBXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P3K0) 3.0 KW / 4.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFINET MCA 120, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131U2824 (FC-302P3K0T5E55H1XGCXXXSXXXXALBXCXXXXDX)
- 131U2824 (FC-302P3K0T5E55H1XGCXXXSXXXXALBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P3K0) 3.0 KW / 4.0 HP, Three phase, 380 - 500 VAC, IP55 / Type 12 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Coated PCB, No Mains Option Latest release standard software. Frame: A5 PROFINET MCA 120, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131U3045 (FC-302P55KT5E55H1XGXXXXSXXXXALBXCXXXXDX)
- 131U3045 (FC-302P55KT5E55H1XGXXXXSXXXXALBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P55K) 55 KW / 75 HP, Three phase, 380 - 500 VAC, IP55 / Type 12 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C2 PROFINET MCA 120, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131U3351 (FC-202P18KT4E55H2XGXXXXSXXXXA0BKCXXXXDX)
- 131U3351 (FC-202P18KT4E55H2XGXXXXSXXXXA0BKCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P18K) 18.5 KW / 25 HP, Three phase, 380 - 480 VAC, IP55 / Type 12 RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: B1 PROFIBUS DP MCA 101, MCB-101 General Purpose I/O No C1 option, No D option Other options according to Model code
-
- Danfoss 131U3667 (FC-302P45KT5E20H1XGXXXXSXXXXALBXCXXXXDX)
- 131U3667 (FC-302P45KT5E20H1XGXXXXSXXXXALBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P45K) 45 KW / 60 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C3 PROFINET MCA 120, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131U3910 (FC-302P2K2T5E20H2XXXXXXSXXXXANBXCXXXXDX)
- 131U3910 (FC-302P2K2T5E20H2XXXXXXSXXXXANBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis RFI Filter No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 EtherNet/IP MCA 121, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131U4005 (FC-302P7K5T5E20H1XGXXXXSXXXXALBXCXXXXDX)
- 131U4005 (FC-302P7K5T5E20H1XGXXXXSXXXXALBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P7K5) 7.5 KW / 10 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A3 PROFINET MCA 120, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131U4060 (FC-202P37KT7E55H2XGCDXXSXXXXAXBXCXXXXDX)
- 131U4060 (FC-202P37KT7E55H2XGCDXXSXXXXAXBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, (P37K) 37 KW / 50 HP, Specific Ratings: 30kW@525- 550V, 40HP@575V, 37kW@690V Three phase, 525 - 690 VAC *, IP55 / Type 12 RFI Filter No brake chopper Graphical Local Control Panel Coated PCB, Loadsharing Latest release standard software. Frame: C2 No A Option, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131U4075 (FC-302P11KT5E20H1XGXXXXSXXXXALBXCXXXXD0)
- 131U4075 (FC-302P11KT5E20H1XGXXXXSXXXXALBXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (P11K) 11 KW / 15 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: B3 PROFINET MCA 120, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code