Drives
Drives
-
Part
Part Number
Manufacturer
Description
-
- Danfoss 131Z7546 (FC-102P45KT4E20H1XGXXXXSXXXXALBXCXXXXD0)
- 131Z7546 (FC-102P45KT4E20H1XGXXXXSXXXXALBXCXXXXD0)
- Danfoss
- VLT HVAC Drive FC-102, (P45K) 45 KW / 60 HP, Three phase, 380 - 480 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C3 PROFINET MCA 120, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model Code
-
- Danfoss 131Z7908 (FC-302P37KT5E20H1XGXXXXSXXXXALBXCXXXXDX)
- 131Z7908 (FC-302P37KT5E20H1XGXXXXSXXXXALBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P37K) 37 KW / 50 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C3 PROFINET MCA 120, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131Z7943 (FC-102P11KT4E20H1TGXXXXSXXXXAXB2CXXXXDX)
- 131Z7943 (FC-102P11KT4E20H1TGXXXXSXXXXAXB2CXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P11K) 11 KW / 15 HP, Three phase, 380 - 480 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Safe Stop Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: B3 No A Option, MCB-112 PTC Therm. Card No C1 option, No D option ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db] Other options according to Model Code
-
- Danfoss 131Z7960 (FC-302P1K5T6E20HXXGXXXXSXXXXA4BXCXXXXDX)
- 131Z7960 (FC-302P1K5T6E20HXXGXXXXSXXXXA4BXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P1K5) 1.5 KW / 2.0 HP, Three phase, 525 - 600 VAC, (E20) IP20 / Chassis No RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A3 DeviceNet MCA 104, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131Z8484 (FC-302P2K2T5Z55H1XGXXXXSXXXXAXB2CXXXXDX)
- 131Z8484 (FC-302P2K2T5Z55H1XGXXXXSXXXXAXB2CXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 500 VAC, IP55 / Type 12 A4 Frame (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A4 No A Option, MCB-112 PTC Therm. Card No C1 option, No D option ATEX: II (2) G [Ex eb Gb] [Ex db Gb] / II (2) D [Ex tb Db] Other options according to Model code
-
- Danfoss 131Z8584 (FC-301P18KT4E20H2XGCXXXSXXXXALBXCXXXXDX)
- 131Z8584 (FC-301P18KT4E20H2XGCXXXSXXXXALBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-301, (P18K) 18.5 KW / 25 HP, Three phase, 380 - 480 VAC, (E20) IP20 / Chassis RFI Filter No brake chopper Graphical Local Control Panel Coated PCB, No Mains Option Latest release standard software. Frame: B4 PROFINET MCA 120, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131Z8697 (FC-302P11KT5E55H1XGCXXXSXXXXALBXCXXXXDX)
- 131Z8697 (FC-302P11KT5E55H1XGCXXXSXXXXALBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P11K) 11 KW / 15 HP, Three phase, 380 - 500 VAC, IP55 / Type 12 (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Coated PCB, No Mains Option Latest release standard software. Frame: B1 PROFINET MCA 120, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 131Z8711 (FC-202P37KT4P55H2XGXXXXSXXXXA0BXCXXXXD0)
- 131Z8711 (FC-202P37KT4P55H2XGXXXXSXXXXA0BXCXXXXD0)
- Danfoss
- VLT AQUA Drive FC-202, (P37K) 37 KW / 50 HP, Three phase, 380 - 480 VAC, IP55 / Type12 Backplate RFI Filter No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: C1 PROFIBUS DP MCA 101, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131Z8781 (FC-102P2K2T4E20H1XGXXXXSXXXXALBXCXXXXDX)
- 131Z8781 (FC-102P2K2T4E20H1XGXXXXSXXXXALBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P2K2) 2.2 KW / 3.0 HP, Three phase, 380 - 480 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFINET MCA 120, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131Z8782 (FC-102P1K5T4E20H1XGXXXXSXXXXALBXCXXXXDX)
- 131Z8782 (FC-102P1K5T4E20H1XGXXXXSXXXXALBXCXXXXDX)
- Danfoss
- VLT HVAC Drive FC-102, (P1K5) 1.5 KW / 2.0 HP, Three phase, 380 - 480 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFINET MCA 120, No B Option No C1 option, No D option Other options according to Model Code
-
- Danfoss 131Z8843 (VLT2830PT4B20SBR1DBF00A00C1)
- 131Z8843 (VLT2830PT4B20SBR1DBF00A00C1)
- Danfoss
- VLT 2800 Series 3.0kW / 4.0 HP, Three Phase, 380-480V 50/60Hz, EN 55011 Class A1, IP20
-
- Danfoss 131Z8865 (FC-202PK55T4E55H1XGXXXXSXXXXALBXCXXXXDX)
- 131Z8865 (FC-202PK55T4E55H1XGXXXXSXXXXALBXCXXXXDX)
- Danfoss
- VLT AQUA Drive FC-202, 0.55 KW / 0.75 HP, Three phase, 380 - 480 VAC, IP55
-
- Danfoss 131Z8969 (VLT2882PT4B20SBR3DBF00A00C1)
- 131Z8969 (VLT2882PT4B20SBR3DBF00A00C1)
- Danfoss
- VLT 2800 Series 18.5kW / 25 HP, Three Phase, 380-480V 50/60Hz, Cable Length Dependent (A1 or B), IP20
-
- Danfoss 131Z9219 (FC-302PK37T5E20H1XGCXXXSXXXXALBXCXXXXD0)
- 131Z9219 (FC-302PK37T5E20H1XGCXXXSXXXXALBXCXXXXD0)
- Danfoss
- VLT AutomationDrive FC-302, (PK37) 0.37 KW / 0.50 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper Graphical Local Control Panel Coated PCB, No Mains Option Latest release standard software. Frame: A2 PROFINET MCA 120, No B Option No C1 option, MCB-107 24V DC backup Other options according to Model code
-
- Danfoss 131Z9438 (FC-302P18KT5E20H1BGXXXXSXXXXALBXCXXXXDX)
- 131Z9438 (FC-302P18KT5E20H1BGXXXXSXXXXALBXCXXXXDX)
- Danfoss
- VLT AutomationDrive FC-302, (P18K) 18.5 KW / 25 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper Graphical Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: B4 PROFINET MCA 120, No B Option No C1 option, No D option Other options according to Model code
-
- Danfoss 132B0100
- 132B0100
- Danfoss
- VLT Control Panel LCP 11 w/o potmeter Local control panel for VLT Micro Drive FC51. Enclosure IP20/Front IP54. Numerical LCP with Quick-Menu for commissioning and local control. Status readout, Hand/Auto-selection, Reset and Navigation keys, Copy and parameter store functionality.
-
- Danfoss 132B0101
- 132B0101
- Danfoss
- VLT Control Panel LCP 12, w. potmeter Numerical control unit with integrated potentiometer for VLT Micro Drive FC 51. Fully enclosed housing design (IP20 / front IP54). Quick menu for quick commissioning, manual / auto switchover and alarm acknowledgment. With copy function to save and transfer the device parameters.
-
- Danfoss 132B0102
- 132B0102
- Danfoss
- LCP Remote Mounting Kit,w/ 3m cable Remote installation kit for VLT Micro Drive FC 51 for installing an LCP 11 or LCP 12 control unit in a control cabinet door or similar. (can also be retrofitted). Contains fastening elements, seal and 3 m connection cable with plugs. LCP is not included in the scope of delivery.
-
- Danfoss 132B0103
- 132B0103
- Danfoss
- Nema 1 Conversion Kit, M1
-
- Danfoss 132B0104
- 132B0104
- Danfoss
- Nema 1 Conversion Kit, M2
-
- Danfoss 132B0105
- 132B0105
- Danfoss
- Nema 1 Conversion Kit, M3
-
- Danfoss 132B0106
- 132B0106
- Danfoss
- Decoupling Plate Mounting Kit, M1, M2 EMC Disconnect Kit for VLT Micro Drive FC-051 For enclosure sizes M1 and M2. Product group: M
-
- Danfoss 132B0107
- 132B0107
- Danfoss
- Decoupling Plate Mounting Kit, M3
-
- Danfoss 132B0108
- 132B0108
- Danfoss
- IP21/Type1 conversion kit, M1
-
- Danfoss 132B0109
- 132B0109
- Danfoss
- IP21/Type1 conversion kit, M2 IP21 covers for VLT Micro Drive FC 51 in size M2. Increases the degree of protection of the housing and offers additional protection against accidental contact. Minimum delivery quantity: 3 (in a collective box with individual packaging)