PLC Systems
PLC Systems
-
Part
Part Number
Manufacturer
Description
-
- B&R X20AI2636
- X20AI2636
- B&R
- The module is equipped with 2 inputs with 16-bit digital converter resolution. It is possible to select between the current and voltage signal using different terminals. With the oversampling function, up to 16 analog values per channel can be recorded. This module is designed for X20 6-pin terminal blocks. If needed (e.g. for logistical reasons), the 12-pin terminal block can also be used.
-
- B&R X20AI4222
- X20AI4222
- B&R
- The module is equipped with 4 inputs with 13-bit (including sign) digital converter resolution. It can be used to capture voltage signals in the range from ±10 V.
-
- B&R X20AI4322
- X20AI4322
- B&R
- The module is equipped with 4 inputs with 12-bit digital converter resolution. It is possible to select between the two current ranges 0 to 20 mA and 4 to 20 mA.
-
- B&R X20AI4622
- X20AI4622
- B&R
- X20 analog input module, 4 inputs, ±10 V or 0 to 20 mA / 4 to 20 mA, 13-bit converter resolution, configurable input filter
-
- B&R X20AI4632
- X20AI4632
- B&R
- The module is equipped with 4 inputs with 16-bit digital converter resolution. It is possible to select between the current and voltage signal using different terminals.
-
- B&R X20AI4632-1
- X20AI4632-1
- B&R
- The module is equipped with 4 inputs with 16-bit digital converter resolution. It is possible to select between the current and voltage signal using different terminals.
-
- B&R X20AI4636
- X20AI4636
- B&R
- The module is equipped with 4 inputs with 16-bit digital converter resolution. It is possible to select between the current and voltage signal using different terminals. With the oversampling function, up to 16 analog values per channel can be recorded.
-
- B&R X20AI8221
- X20AI8221
- B&R
- The module is equipped with 8 inputs with 13-bit (including sign) digital converter resolution. It can be used to capture voltage signals in the range from ±10 V.
-
- B&R X20AI8321
- X20AI8321
- B&R
- The module is equipped with 8 inputs with 12-bit digital converter resolution. It is possible to select between the two current ranges 0 to 20 mA and 4 to 20 mA.
-
- B&R X20AIA744
- X20AIA744
- B&R
- This module works with 4-wire strain gauge load cells. The concept applied by the module requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature.
-
- B&R X20AIB744
- X20AIB744
- B&R
- This module works with 4-wire strain gauge load cells. The concept applied by the module requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature.
-
- B&R X20AO2437
- X20AO2437
- B&R
- The module is equipped with 2 current outputs with 16-bit digital converter resolution. The 2 channels are electrically isolated from each other. The user can select between the 3 output ranges 4 to 20 mA, 0 to 20 mA and 0 to 24 mA.
-
- B&R X20AO2438
- X20AO2438
- B&R
- The module is equipped with 2 current outputs with 16-bit digital converter resolution. It supports the HART communication standard for data transfer, parameter configuration and diagnostics. The 2 channels are electrically isolated from each other. The user can select between the 3 output ranges 4 to 20 mA, 0 to 20 mA and 0 to 24 mA.
-
- B&R X20AO2622
- X20AO2622
- B&R
- The module is equipped with 2 outputs with 13-bit (including sign) digital converter resolution. It is possible to select between the current and voltage signal using different terminals. This module is designed for X20 6-pin terminal blocks. If needed (e.g. for logistical reasons), the 12-pin terminal block can also be used.
-
- B&R X20AO2632
- X20AO2632
- B&R
- The module is equipped with 2 outputs with 16-bit (including sign) digital converter resolution. It is possible to select between the current and voltage signal using different terminals. This module is designed for X20 6-pin terminal blocks. If needed (e.g. for logistical reasons), the 12-pin terminal block can also be used. NetTime timestamp for output For many applications, not only the output value is important, but also the exact switching time. The module is equipped with a NetTime timestamp function for this that can define a switching time to the nearest microsecond. The timestamp function is based on synchronized timers. The CPU can predefine output events and provide them with a timestamp. After transferring the respective data, including the exact time, the module executes the predefined action at the exactly defined time.
-
- B&R X20AO4622
- X20AO4622
- B&R
- X20 analog output module, 4 outputs, 10 V or 0 to 20 mA / 4 to 20 mA, 13-bit converter resolution
-
- B&R X20AO4632
- X20AO4632
- B&R
- The module is equipped with 4 outputs with 16-bit (including sign) digital converter resolution. It is possible to select between the current and voltage signal using different terminals.
-
- B&R X20AO4632-1
- X20AO4632-1
- B&R
- The module is equipped with 4 outputs with 16-bit (including sign) digital converter resolution. It is possible to select between the current and voltage signal using different terminals.
-
- B&R X20AO4635
- X20AO4635
- B&R
- The module is equipped with 4 outputs with 16-bit (including sign) digital converter resolution. It is possible to select between the current and voltage signal using different terminals.
-
- B&R X20AT2222
- X20AT2222
- B&R
- The module is equipped with 2 inputs for PT100/PT1000 resistance temperature measurement. This module is designed for X20 6-pin terminal blocks. If needed (e.g. for logistical reasons), the 12-pin terminal block can also be used.
-
- B&R X20AT2311
- X20AT2311
- B&R
- The module is equipped with 2 inputs for PT100 4-line resistance temperature measurement.
-
- B&R X20AT2402
- X20AT2402
- B&R
- The module is equipped with 2 inputs for J, K, N, S, B and R thermocouple sensors. The module has an integrated terminal temperature compensation. This module is designed for X20 6-pin terminal blocks. If needed (e.g. for logistical reasons), the 12-pin terminal block can also be used.
-
- B&R X20AT4222
- X20AT4222
- B&R
- The module is equipped with 4 inputs for PT100/PT1000 resistance temperature measurement.
-
- B&R X20AT4232
- X20AT4232
- B&R
- This module is equipped with 4 inputs for NTC resistance temperature measurement (10 kΩ at 25°C). In addition, this module can measure resistance from 0 to 200 kΩ.
-
- B&R X20AT6402
- X20AT6402
- B&R
- The module is equipped with 6 inputs for J, K, N, S, B and R thermocouple sensors. The module has an integrated terminal temperature compensation.