PLC Systems
PLC Systems
-
Part
Part Number
Manufacturer
Description
-
- B&R X20cAI4622
- X20cAI4622
- B&R
- X20 analog input module, coated, 4 inputs, ±10 V or 0 to 20 mA / 4 to 20 mA, 13-bit converter resolution, configurable input filter
-
- B&R X20cAI4632-1
- X20cAI4632-1
- B&R
- The module is equipped with 4 inputs with 16-bit digital converter resolution. It is possible to select between the current and voltage signal using different terminals.
-
- B&R X20cAO2437
- X20cAO2437
- B&R
- The module is equipped with 2 current outputs with 16-bit digital converter resolution. The 2 channels are electrically isolated from each other. The user can select between the 3 output ranges 4 to 20 mA, 0 to 20 mA and 0 to 24 mA.
-
- B&R X20cAO2438
- X20cAO2438
- B&R
- The module is equipped with 2 current outputs with 16-bit digital converter resolution. It supports the HART communication standard for data transfer, parameter configuration and diagnostics. The 2 channels are electrically isolated from each other. The user can select between the 3 output ranges 4 to 20 mA, 0 to 20 mA and 0 to 24 mA.
-
- B&R X20cAO4622
- X20cAO4622
- B&R
- X20 analog output module, coated, 4 outputs, 10 V or 0 to 20 mA / 4 to 20 mA, 13-bit converter resolution
-
- B&R X20cAO4632
- X20cAO4632
- B&R
- The module is equipped with 4 outputs with 16-bit (including sign) digital converter resolution. It is possible to select between the current and voltage signal using different terminals.
-
- B&R X20cAT2311
- X20cAT2311
- B&R
- The module is equipped with 2 inputs for PT100 4-line resistance temperature measurement.
-
- B&R X20CAT4222
- X20CAT4222
- B&R
- The module is equipped with 4 inputs for PT100/PT1000 resistance temperature measurement.
-
- B&R X20cAT6402
- X20cAT6402
- B&R
- The module is equipped with 6 inputs for J, K, N, S, B and R thermocouple sensors. The module has an integrated terminal temperature compensation.
-
- B&R X20cBB52
- X20cBB52
- B&R
- The bus module is the base for all X20 Compact-S CPUs. The left and right end cover plates are included in delivery.
-
- B&R X20cBB57
- X20cBB57
- B&R
- The bus module is the base for all X20 Compact-S CPUs. The left and right end cover plates are included in delivery.
-
- B&R X20cBB80
- X20cBB80
- B&R
- The following modules are used on the bus module: The left and right end cover plates are included in delivery.
-
- B&R X20cBB82
- X20cBB82
- B&R
- The bus module has 2 expansion slots. The following modules are used on this module: The left and right end cover plates are included in delivery.
-
- B&R X20cBC0043-10
- X20cBC0043-10
- B&R
- X20 bus controller, coated, 1 CANopen interface, order 1x terminal block TB2105 separately! Order bus base, power supply module and terminal block separately!
-
- B&R X20cBC0083
- X20cBC0083
- B&R
- The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org.
-
- B&R X20cBC0087
- X20cBC0087
- B&R
- Established in 1979, the Modbus protocol has approved the use of Ethernet with both Modbus TCP and Modbus/UDP. Today, Modbus TCP is an open Internet draft standard introduced by Schneider Automation to the Internet Engineering Task Force (IETF), the organization responsible for Internet standardization. The Modbus services and object model have been preserved since the original version and left unchanged for use with the TCP/IP transmission medium. Modbus/UDP differs from Modbus TCP in that it uses connectionless communication via UDP/IP. The advantages of faster and easier communication with UDP/IP also brings with it the disadvantage of requiring error detection and correction in the application layer. This bus controller makes it possible to connect X2X Link I/O nodes to Modbus via Ethernet. The bus controller can be operated on B&R controllers through the use of Automation Studio or on third-party systems with Modbus TCP or -UDP master functionality.
-
- B&R X20cBC0088
- X20cBC0088
- B&R
- EtherNet/IP is an Ethernet-based fieldbus. EtherNet/IP was developed by Allen-Bradley (Rockwell Automation) and later transferred to the Open DeviceNet Vendor Association (ODVA) as an open standard. In 1998, a working group at ControlNet International developed a procedure for setting the published Common Industrial Protocol to Ethernet. EtherNet/IP was published in March 2000 as an open industrial automation standard based on this procedure. This bus controller makes it possible to connect X2X Link I/O nodes to EtherNet/IP. The bus controller can be operated via interface module X20IF10D1-1 or by 3rd-party systems with EtherNet/IP scanner functionality.
-
- B&R X20cBC00E3
- X20cBC00E3
- B&R
- PROFINET (Process Field Network) is an Industrial Ethernet protocol. It uses TCP/IP and is real-time capable. X20 modules or other modules based on X2X Link can be connected to the bus controller. Modular system configurations are optimally supported by PROFINET. Using the device description file (GSDML format), it is very easy to handle project configuration in the respective engineering tool from the manufacturer of the master device.
-
- B&R X20cBC1083
- X20cBC1083
- B&R
- The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org. The bus modules expanded to the left allow connection of up to 2 interface modules in addition to the bus controller.
-
- B&R X20cBC8083
- X20cBC8083
- B&R
- The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org. The bus modules expanded to the left allow connection of up to 2 hub expansion modules in addition to the bus controller. Each expansion module is equipped with 2 RJ45 connections. This means that a basic device provides up to 6 hub connections.
-
- B&R X20cBC8084
- X20cBC8084
- B&R
- The bus controller makes it possible to connect X2X Link I/O nodes to POWERLINK. It is also possible to operate the X2X Link cycle synchronously 1:1 or synchronous to POWERLINK using a prescaler. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed:: www.ethernet-powerlink.org. Systems with redundant cabling can be implemented easily using POWERLINK. Unlike ring redundancy, cable redundancy does not require cable looping, which can sometimes be problematic. This allows the creation of all types of tree structures. When using a device with the link selector function, data is always transferred via the highest quality network lines. The link selector function is integrated in the bus controller.
-
- B&R X20cBM01
- X20cBM01
- B&R
- The bus module is the base for all power supply modules.
-
- B&R X20cBM11
- X20cBM11
- B&R
- The bus module is the base for all 24 VDC I/O modules. The internal I/O power supply is connected through.
-
- B&R X20cBM12
- X20cBM12
- B&R
- The bus module serves as the base for all 240 VAC X20 I/O modules. The internal I/O supply is interconnected.
-
- B&R X20cBM31
- X20cBM31
- B&R
- The bus module serves as a basis for all double-width X20 I/O modules. The internal I/O supply is interconnected.