PLC Systems
PLC Systems
-
Part
Part Number
Manufacturer
Description
-
- B&R X20cDO6639
- X20cDO6639
- B&R
- The module is equipped with 6 relay outputs.
-
- B&R X20cDO8332
- X20cDO8332
- B&R
- The module is equipped with 8 outputs for 1-wire connections. The rated output current is 2 A. The output supply is fed directly to the module. An additional supply module is not needed. There is no connection between the module and the I/O supply potential on the bus module.
-
- B&R X20cDO9321
- X20cDO9321
- B&R
- The module is equipped with 12 outputs for 1-wire connections. The module is designed for sink output wiring.
-
- B&R X20cDO9322
- X20cDO9322
- B&R
- The module is equipped with 12 outputs for 1-wire connections. The module is designed for source output wiring.
-
- B&R X20cDOF322
- X20cDOF322
- B&R
- The module is equipped with 16 outputs for 1-wire connections. The module is designed for source output wiring.
-
- B&R X20cDS438A
- X20cDS438A
- B&R
- The module is an IO-Link master that allows intelligent sensors and actuators to be connected to the X20 system in accordance with the IO-Link standard. The module can be used to operate up to 4 IO-Link devices. All IO-Link channels can be used either as standard digital inputs or outputs.
-
- B&R X20cHB1881
- X20cHB1881
- B&R
- The POWERLINK bus controllers X20BC8083, X20BC8084 (revision D0 or higher) and the stand-alone hub X20HB8880 are equipped with a modular hub expansion. An additional 1 or 2 slots are available, depending on the bus base used. The X20HB1881 hub expansion module can be operated in these slots. Note that the hardware revision of the X20BC8083 and the X20HB8880 must be ≥F0. The hub expansion module is a 1x hub. The Ethernet connection is made using 62.5/125 μm or 50/125 µm fiber optic multimode cable with a duplex LC connection. The module and network status is indicated using LEDs.
-
- B&R X20cHB2880
- X20cHB2880
- B&R
- The POWERLINK bus controller X20BC8083 and the stand-alone hubs X20HB8880 and X20HB8815 are equipped with a modular hub expansion. An additional 1 or 2 slots are available, depending on the bus base used. The X20HB2880 hub expansion module can be operated in these slots. The status of the module and network are indicated by LEDs.
-
- B&R X20cHB2881
- X20cHB2881
- B&R
- The POWERLINK bus controller X20BC8083 and the stand-alone hubs X20HB8880 and X20HB8815 are equipped with a modular hub expansion. An additional 1 or 2 slots are available, depending on the bus base used. The X20HB2881 hub expansion module can be operated in these slots. Note that the hardware revision of the X20BC8083 and the X20HB8880 must be ≥F0. The hub expansion module is a 2x hub. The Ethernet connection is made using 62.5/125 μm or 50/125 µm fiber optic multimode cable with a duplex LC connection. The status of the module and network are indicated by LEDs.
-
- B&R X20cHB2885
- X20cHB2885
- B&R
- The X20BC8084 POWERLINK bus controller and the X20HB8884 module are equipped with an integrated link selector function. An additional 1 or 2 slots are available, depending on the bus base used. The active X20HB2885 hub expansion module can be operated in these slots. The active hub expansion module is equipped with one integrated 2x hub and allows redundant wiring. This means that the connection between the two ports remains intact if there is a failure in the bus controller or Compact Link Selector. The status of the module and network are indicated by LEDs.
-
- B&R X20cHB2886
- X20cHB2886
- B&R
- The X20BC8084 POWERLINK bus controller and the X20HB8884 module are equipped with an integrated link selector function. An additional 1 or 2 slots are available, depending on the bus base used. The active X20HB2886 hub expansion module can be operated in these slots. Note that the hardware revision of the X20BC8084 and the X20HB8884 must be ≥E0. The active hub expansion module is equipped with one integrated 2x hub and allows redundant wiring. This means that the connection between the two 100 Base-FX interfaces remains intact if there is a failure in the bus controller or Compact Link Selector. The Ethernet connection is made using 62.5/125 μm or 50/125 µm fiber optic multimode cable with a duplex LC connection. The status of the module and network are indicated by LEDs.
-
- B&R X20cHB8815
- X20cHB8815
- B&R
- The POWERLINK TCP/IP gateway enables the exchange of all types of application data (HMI, diagnostics, parameter data, etc.) between a POWERLINK V2 network and a TCP/IP network. It functions like a layer 2 switch, with the exception that cyclic POWERLINK packets are not routed to the ETH port. With respect to the functionality of layer 2 switches, it should be mentioned that the gateway uses the store-and-forward principle. Gateway functionality doesn't need to be configured separately. When the gateway receives a frame, it saves the MAC address of the sender and the corresponding interface in the source address table (SAT). If the destination address is found in the SAT, the gateway routes the frame to the corresponding interface. Frames with a broadcast or multicast address are always routed to all interfaces. When IP packets are received at the "ETH" port that are larger than the MTU configured for POWERLINK, they are fragmented, if permitted. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG, see www.ethernet-powerlink.org) ensures its openness and continual development. The bus modules expanded to the left allow connection of up to 2 hub expansion modules in addition to the gateway. This means that a basic device provides up to 2 POWERLINK ports.
-
- B&R X20cHB8880
- X20cHB8880
- B&R
- The X20 hub is a device that can be used universally in standard Ethernet networks or POWERLINK networks. It is suitable for 100 Mbit/s (Fast Ethernet) networks. The bus modules expanded to the left allow connection of up to 2 hub expansion modules in addition to the hub base module. This means that a single base device provides up to 6 hub interfaces.
-
- B&R X20cHB8884
- X20cHB8884
- B&R
- POWERLINK is a standard protocol for Fast Ethernet with hard real-time properties. The Ethernet POWERLINK Standardization Group (EPSG) ensures that the standard remains open and is continually developed. www.ethernet-powerlink.org Systems with redundant cabling can be implemented easily using POWERLINK. Unlike ring redundancy, cable redundancy does not require cable looping, which can sometimes be problematic. This allows the creation of all types of tree structures. When using a device with the link selector function, data is always transferred via the highest quality network lines. The link selector function is integrated in the module compact link selector. This makes it easy to connect any POWERLINK device to a redundant POWERLINK network.
-
- B&R X20cIF1030
- X20cIF1030
- B&R
- The interface module can be used to expand the X20 CPU for specific applications. It is equipped with an RS485/RS422 interface.
-
- B&R X20cIF1041-1
- X20cIF1041-1
- B&R
- The interface module is equipped with a CANopen interface. This allows third-party components to be integrated in the B&R system and makes it possible to quickly and easily transfer data in both directions. The interface module can be operated in X20 CPUs or in the expandable POWERLINK bus controller X20BC1083.
-
- B&R X20cIF1061-1
- X20cIF1061-1
- B&R
- The interface module is equipped with a PROFIBUS DP V1 interface. This allows third-party components to be integrated in the B&R system and makes it possible to quickly and easily transfer data in both directions. The interface module can be operated in X20 CPUs or in the expandable POWERLINK bus controller X20BC1083.
-
- B&R X20cIF1063-1
- X20cIF1063-1
- B&R
- The interface module is equipped with a PROFIBUS DP V1 interface. This allows the B&R system (I/O modules, POWERLINK, etc.) to be connected to systems from other manufacturers and makes it possible to quickly and easily transfer data in both directions. The interface module can be operated in X20 CPUs or in the expandable POWERLINK bus controller X20BC1083.
-
- B&R X20cIF1072
- X20cIF1072
- B&R
- The interface module can be used to expand the X20 CPU for specific applications. It is equipped with a CAN bus interface.
-
- B&R X20cIF1082-2
- X20cIF1082-2
- B&R
- The interface module can be used to expand the X20 CPU for specific applications. It is equipped with an POWERLINK interface. The interface has two RJ45 sockets. Both connections lead to an integrated hub. This makes it easy to create daisy-chain connections using POWERLINK.
-
- B&R X20cIF10D1-1
- X20cIF10D1-1
- B&R
- The interface module is equipped with an EtherNet/IP scanner interface. This allows third-party components to be integrated in the B&R system and makes it possible to quickly and easily transfer data in both directions. The interface module can be operated in X20 CPUs or in the expandable POWERLINK bus controller X20BC1083. The interface is equipped with 2 RJ45 connections. Both connections result in an integrated switch. This makes it easy to implement daisy chain cabling.
-
- B&R X20cIF10D3-1
- X20cIF10D3-1
- B&R
- The interface module is equipped with an EtherNet/IP adapter interface. This allows the B&R system (I/O modules, POWERLINK, etc.) to be connected to systems from other manufacturers and makes it possible to quickly and easily transfer data in both directions. The interface module can be operated in X20 CPUs or in the expandable POWERLINK bus controller X20BC1083. The interface is equipped with 2 RJ45 connections. Both connections result in an integrated switch. This makes it easy to implement daisy chain cabling.
-
- B&R X20cIF10E3-1
- X20cIF10E3-1
- B&R
- The interface module is equipped with a PROFINET IO device interface. This allows the B&R system (I/O modules, POWERLINK, etc.) to be connected to systems from other manufacturers and makes it possible to quickly and easily transfer data in both directions. The interface module can be operated in X20 CPUs or in the expandable POWERLINK bus controller X20BC1083. The interface is equipped with 2 RJ45 connections. Both connections result in an integrated switch. This makes it easy to implement daisy chain cabling.
-
- B&R X20cIF10X0
- X20cIF10X0
- B&R
- Interface module for the operation of redundant CPUs.
-
- B&R X20cIF2181-2
- X20cIF2181-2
- B&R
- The interface module is used to expand the X20 CPU for specific applications. It is equipped with an POWERLINK interface. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG, see www.ethernet-powerlink.org) ensures its openness and continual development. Systems with redundant cabling can be implemented easily using POWERLINK. Unlike ring redundancy, cable redundancy does not require cable looping, which can sometimes be problematic. This allows the creation of all types of tree structures. When using a device with the link selector function, data is always transferred via the highest quality network lines. The link selector function is integrated in the X20IF2181-2 module.