PLC Systems
PLC Systems
-
Part
Part Number
Manufacturer
Description
-
- B&R X67DI1372
- X67DI1372
- B&R
- This module is a digital input module for 24 VDC. It is equipped with 8 inputs for a source input circuit.
-
- B&R X67DM1321
- X67DM1321
- B&R
- This module is equipped with 8 digital channels that can be configured either as inputs or outputs. The inputs are designed for a sink circuit, and the outputs are designed for a source circuit.
-
- B&R X67DM1321.L08
- X67DM1321.L08
- B&R
- This module is equipped with 16 digital channels that can be configured either as inputs or outputs. The inputs are designed for a sink circuit, and the outputs are designed for a source circuit.
-
- B&R X67DM1321.L12
- X67DM1321.L12
- B&R
- This module is equipped with 16 digital channels that can be configured either as inputs or outputs. The inputs are designed for a sink circuit, and the outputs are designed for a source circuit.
-
- B&R X67DM1321.L12-1
- X67DM1321.L12-1
- B&R
- This module is equipped with 16 digital channels that can be configured either as inputs or outputs. The inputs are designed for a sink circuit, and the outputs are designed for a source circuit.
-
- B&R X67DM9321
- X67DM9321
- B&R
- This module is equipped with 8 digital channels that can be configured either as inputs or outputs. The inputs are designed for a sink circuit, and the outputs are designed for a source circuit. The node number switch for setting the X2X Link address is a unique feature. When modular machine configurations change, it is required, for example, to define certain module groups at a fixed address that is independent of the preceding modules in the line. All subsequent standard modules refer to this offset and use it automatically for addressing purposes.
-
- B&R X67DM9321.L12
- X67DM9321.L12
- B&R
- This module is equipped with 16 digital channels that can be configured either as inputs or outputs. The inputs are designed for a sink circuit, and the outputs are designed for a source circuit. The node number switch for setting the X2X Link address is a unique feature. When modular machine configurations change, it is required, for example, to define certain module groups at a fixed address that is independent of the preceding modules in the line. All subsequent standard modules refer to this offset and use it automatically for addressing purposes.
-
- B&R X67DM9331.L12
- X67DM9331.L12
- B&R
- This module is equipped with 8 digital channels that can be configured either as inputs or outputs. The inputs are designed for a sink circuit, and the outputs are designed for a source circuit. The outputs can be loaded with up to 2 A. The summation current is 8 A. The node number switch for setting the X2X Link address is a unique feature. When modular machine configurations change, it is required, for example, to define certain module groups at a fixed address that is independent of the preceding modules in the line. All subsequent standard modules refer to this offset and use it automatically for addressing purposes.
-
- B&R X67DO1332
- X67DO1332
- B&R
- Digital output module for 24 VDC, equipped with 8 outputs for a source output circuit.
-
- B&R X67DO9332.L12
- X67DO9332.L12
- B&R
- The module is a digital output module with 8 channels. The outputs can be loaded with up to 2 A. The summation current is 8 A. The node number switches for setting the X2X Link address are a unique feature. When modular machine configurations change, it is required, for example, to define certain module groups at a fixed address that is independent of the preceding modules in the line. All subsequent standard modules refer to this offset and use it automatically for addressing purposes.
-
- B&R X67DS438A
- X67DS438A
- B&R
- The module is an IO-Link master that allows intelligent sensor and actuators to be connected in accordance to the IO-Link standard. The module can be used to operate up to 4 IO-Link devices. All IO-Link channels can also be operated in SIO mode if desired and thus used as digital inputs or outputs. The module also has 4 additional digital inputs, which can be used independent of the IO-Link channel configuration.
-
- B&R X67DV1311.L08
- X67DV1311.L08
- B&R
- This module makes it possible to control valve terminals with multi-pin technology. The digital inputs are designed as M8 connectors.
-
- B&R X67HB8880.L12
- X67HB8880.L12
- B&R
- The Ethernet hub is a standalone device that can be used universally as a hub in POWERLINK networks. It is suitable for both 100 Mbit/s (Fast Ethernet) and 10 Mbit/s networks. The hub automatically recognizes the transfer speed for the channels. The Ethernet connections are made using D-keyed M12 connectors. All ports are equipped with auto-MDIX (auto-crossover). The module is designed for a voltage range of 8 to 32 VDC and equipped with a power supply protected against load dump.
-
- B&R X67IF1121-1
- X67IF1121-1
- B&R
- Serial interfaces (barcode scanners for example) are often scattered throughout systems. This interface module from the remote X67 system is the optimal choice for this area of application: RS232 and RS485/RS422 connection options directly where they are needed, distributed on the machine or system. In addition, there are digital inputs and outputs on the same module so that corresponding 24 V sensors/actuators can also be connected.
-
- B&R X67PS1300
- X67PS1300
- B&R
- This system supply module converts the 24 VDC I/O supply voltage into the electrically isolated X2X Link power supply. The module provides 15 W of output power for additional X67 modules on the bus.
-
- B&R X67UM1352
- X67UM1352
- B&R
- This module enables the remote connection of a force gauge using a strain gauge with a converter resolution of up to 24-bit. The data rate can be set from 0.26 ms to 100 ms. This module concept requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero point offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature. The module is also equipped with 4 digital inputs and 2 digital outputs.
-
- B&R X90AC-BB.12-00
- X90AC-BB.12-00
- B&R
- X90 mobile 120, breakout box template and cable adapter for X90AC-BB.17-00 breakout box, for development and tests
-
- B&R X90AC-BB.17-00
- X90AC-BB.17-00
- B&R
- X90 mobile 170, breakout box for development and tests
-
- B&R X90AISG0.02-00
- X90AISG0.02-00
- B&R
- This module is equipped with 2 inputs for evaluating full-bridge strain gauges and works with 4-wire and 6-wire strain gauge load cells. The concept applied by the module requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature. Communication to the mainboard is made possible via X2X Link.
-
- B&R X90AO410.04-00
- X90AO410.04-00
- B&R
- The AO option board offers 4 additional analog outputs, each of which can be configured as a current or voltage output. Communication to the mainboard is made possible via X2X Link. The pins in use can also be used as digital inputs; it is possible to toggle them between sink mode and source mode.
-
- B&R X90AO410.08-00
- X90AO410.08-00
- B&R
- The AO option board offers 8 additional analog outputs, each of which can be configured as a current or voltage output. Communication to the mainboard is made possible via X2X Link. The pins in use can also be used as digital inputs; it is possible to toggle them between sink mode and source mode.
-
- B&R X90AT910.04-00
- X90AT910.04-00
- B&R
- The AT option board offers 4 additional channels that can be used for current, voltage or temperature measurement. It is also possible to use the analog inputs as PWM signal outputs or digital inputs (with toggling between sink mode and source mode). Communication to the mainboard is made possible via X2X Link.
-
- B&R X90AT910.08-00
- X90AT910.08-00
- B&R
- The AT option board offers 8 additional channels that can be used for current, voltage or temperature measurement. It is also possible to use the analog inputs as PWM signal outputs or digital inputs (with toggling between sink mode and source mode). Communication to the mainboard is made possible via X2X Link.
-
- B&R X90BC124.32-00
- X90BC124.32-00
- B&R
- Bus controller module X90BC124.32-00 is a configurable CANopen slave module for sensor and actuator management. 32 multifunction inputs and outputs are available for a wide range of tasks. The robust die-cast aluminum housing enables use in harsh ambient conditions.
-
- B&R X90CA100.02-00
- X90CA100.02-00
- B&R
- X90 mobile 170, wiring harness starter set for X90CP17x, 2 m, for CMC header