PLC Systems
PLC Systems
-
Part
Part Number
Manufacturer
Description
-
- Siemens 6BK1700-0BA00-0AA1
- 6BK1700-0BA00-0AA1
- Siemens
- Communication module LOGO! communication module EIB as interface between EIB and LOGO! PS 24 V DC/AC Image via bus v. max.: 16 DI, 12 DO, 8 AI and 2 AO
-
- Siemens 6BK1700-0BA000-AA2
- 6BK1700-0BA000-AA2
- Siemens
- Communication module LOGO! communication module EIB as interface between EIB and LOGO! PS 24 V DC/AC Image via bus v. max.: 16 DI, 12 DO, 8 AI and 2 AO
-
- Siemens 6BK1700-0BA10-0AA0
- 6BK1700-0BA10-0AA0
- Siemens
- Communication module LOGO! communication module LON as interface between LON and LOGO! PS 24 V DC/AC Image via bus v. max.: 16 DI, 12 DO und 8 AI
-
- Siemens 6BK1700-0BA20-0AA0
- 6BK1700-0BA20-0AA0
- Siemens
- LOGO! CMK2000 Communication module for integrating the LOGO! 8 "in the building system bus KNX;" connection 24 V DC 0.04A 1 RJ45 port for Ethernet 50 communication objects time-of-day synchronization Configuration/diagnostics via web interface
-
- Siemens 6BK1700-2AA00-0AA1
- 6BK1700-2AA00-0AA1
- Siemens
- SIPLUS HCS716I rack, swing frame version, For holding up to 12 power output modules LA716, LA716I and LA716I HP. The contacting of the L module via direct connectors on a bus PCB which the rear of the module rack connected. The control module with the ASIC DPC31 for PROFIBUS connection located on the rear side of the enclosure
-
- Siemens 6BK1700-2AA10-0AA0
- 6BK1700-2AA10-0AA0
- Siemens
- Subrack mounting frame
-
- Siemens 6BK1700-2AA10-0AA1
- 6BK1700-2AA10-0AA1
- Siemens
- SIPLUS HCS716I rack, mounting frame version, For holding up to 12 power output modules LA716, LA716I and LA716I HP. The contacting of the L module via direct connectors on a bus PCB which the rear of the module rack connected. The control module with the ASIC DPC31 for PROFIBUS connection is on the right side section of the enclosure
-
- Siemens 6BK1700-2AA20-0AA1
- 6BK1700-2AA20-0AA1
- Siemens
- SIPLUS HCS716I rack, swing frame version, For holding up to 12 power output modules LA716, LA716I and LA716I HP. The contacting of the L module via direct connectors on a bus PCB which the rear of the module rack connected. The control module with the ASIC DPC31 for PROFIBUS connection located on the rear side of the enclosure.
-
- Siemens 6BK1700-2AA80-0AA0
- 6BK1700-2AA80-0AA0
- Siemens
- SIPLUS HCS716I rack, narrow mounting frame version, for holding up to 4 power output modules LA716, LA716I and LA716I HP. The contacting of the L module via direct connectors on a bus PCB which the rear of the module rack connected. The control module with the ASIC DPC31 for PROFIBUS connection is on the right side section of the enclosure
-
- Siemens 6BK1700-2BA00-0AA0
- 6BK1700-2BA00-0AA0
- Siemens
- SIPLUS HCS724I LA724I power output for central connection ZA724I.
-
- Siemens 6BK1700-2BA20-0AA0
- 6BK1700-2BA20-0AA0
- Siemens
- POWER OUTPUT MODULE FOR HEATING CONTROL SYSTEM SIPLUS HCS724I. LA 724I HP HEATING CONTROL SYSTEM POWER OUTPUT (HIGH POWER VERSION) FOR USE WITH A ZA724I (CENTRAL INTERFACE MODULE, ORDER NR.: 6BK1700-2BA30-0AA0) NOTE: THE 3 MATING CONNECTORS FOR CONNECTING LOADS ARE NOT INCLUDED IN THE SCOPE OF SUPPLY OF POWER OUTPUT MODULE AND CAN BE ORDERED OPTIONALLY UNDER ORDER NUMBER WKF:40018384 FOR ORDER SEE INFORMATION ABOUT CONNECTOR IN PMD.
-
- Siemens 6BK1700-2BA30-0AA0
- 6BK1700-2BA30-0AA0
- Siemens
- SIPLUS HCS724I Central connection ZA724I Connection to PROFIBUS DP 12 Mbaud. Required for operation are power outputs: LA724I (6BK1700-2BA00-0AA0) LA724I HP (6BK1700-4BA70-0AA0) LA724I SSR (6BK1700-2BA10-0AA0)
-
- Siemens 6BK1700-2BA70-0AA1
- 6BK1700-2BA70-0AA1
- Siemens
- SIPLUS HCS716I LA716 power output module with 16 channels max. 650 W each. For operation, a rack is required. The 5x 20 mm fuses 5AMP. quick-action are (replaceable) to be plugged onto open fuse holders; 2-phase line infeed via front-side 3-pole connection terminal. Radiator outlets via 2x8-pole pin connectors (not included in scope of supply)
-
- Siemens 6BK1700-2BA80-0AA0
- 6BK1700-2BA80-0AA0
- Siemens
- SIPLUS HCS300I Digital output module DM6 With integrated interface for connection of the connecting cable to the solid-state relay. The pre-assembled cables are available under the order numbers 6BK1700-2FA00-0AA0 and 6BK1700-2FA10-0AA0
-
- Siemens 6BK1700-2GA00-0AA0
- 6BK1700-2GA00-0AA0
- Siemens
- SIPLUS HCS4300 fan for HCS POM4320
-
- Siemens 6BK1700-3BA20-0AA0
- 6BK1700-3BA20-0AA0
- Siemens
- SIPLUS HCS300I Basic unit DC=24V
-
- Siemens 6BK1700-4BA60-0AA0
- 6BK1700-4BA60-0AA0
- Siemens
- SIPLUS HCS300I Temperature measuring module TM4
-
- Siemens 6BK1700-4BA70-0AA0
- 6BK1700-4BA70-0AA0
- Siemens
- SIPLUS HCS724I LA724I HP power output for central interface ZA724I.
-
- Siemens 6BK1700-4BA80-0AA0
- 6BK1700-4BA80-0AA0
- Siemens
- SIPLUS HCS716I LA716I power output module with 16 channels max. 1150 W each. For operation, a rack is required. The 5x 20 mm fuses associated with each channel 5 A quick-response are (replaceable) to be plugged onto open fuse holders; 2-phase line infeed via front-side 3-pole connector (included in scope of supply). Radiator outlets via 2x8-pole pin connectors (not included in scope of supply)
-
- Siemens 6BK1900-0AA00-0AA0
- 6BK1900-0AA00-0AA0
- Siemens
- SIPLUS HCS4000 IO module temperature for acquisition of temperatures
-
- Siemens 6BK1900-0BA00-0AA0
- 6BK1900-0BA00-0AA0
- Siemens
- SIPLUS HCS4000 IO module DI/DQ with 8 digital outputs and 8 configurable digital inputs or outputs
-
- Siemens 6BK1900-0CA00-0AA0
- 6BK1900-0CA00-0AA0
- Siemens
- SIPLUS HCS4000 IO module U/I for measuring voltages and currents
-
- Siemens 6BK1900-6AA00-0AA0
- 6BK1900-6AA00-0AA0
- Siemens
- Replacement part SIPLUS HCS4x00 connector set for PM4000 U/I consisting of 10 plugs
-
- Siemens 6BK1900-6BA00-0AA0
- 6BK1900-6BA00-0AA0
- Siemens
- Replacement part SIPLUS HCS4000 connector set for PM DI/DQ consisting of 8 plugs
-
- Siemens 6BK1932-0AA00-0AA0
- 6BK1932-0AA00-0AA0
- Siemens
- SIPLUS HCS3200 compact heating control in degree of protection IP65 and UL Recognized certification. 9 power outputs max. 4000 W each. Please note: mating connectors are not included in scope of supply