Safety Automation
Safety Automation
-
Part
Part Number
Manufacturer
Description
-
- B&R X20BM23
- X20BM23
- B&R
- The bus module is the base for all SafeIO power supply modules. The internal I/O power supply is interrupted to the left.
-
- B&R X20BM26
- X20BM26
- B&R
- The bus module is the base for all SafeIO power supply modules. The internal I/O power supply is interrupted to the left. In addition, a unique address is defined with this bus module using a node number switch.
-
- B&R X20BM33
- X20BM33
- B&R
- The bus module is the base for all SafeIO modules. The internal I/O power supply is continuous.
-
- B&R X20BM36
- X20BM36
- B&R
- The bus module is the base for all SafeIO modules. The internal I/O power supply is continuous. In addition, a unique address is defined with this bus module using a node number switch.
-
- B&R X20cBM33
- X20cBM33
- B&R
- The bus module is the base for all SafeIO modules. The internal I/O power supply is continuous.
-
- B&R X20cSA4430
- X20cSA4430
- B&R
- The module is equipped with 2 safe analog input pairs for current measurement. Each input pair has its own sensor power supply. The channels with their respective sensor supplies are electrically isolated from each other. It can be used to capture current signals in the range from 0.5 to 25 mA. The safe analog input module is suitable for safely acquiring current signals for safety-related applications up to PL e or SIL 3. This module is designed for X20 16-pin terminal blocks.
-
- B&R X20cSC2212
- X20cSC2212
- B&R
- The module is equipped with 6 safe digital inputs and 2 safe digital outputs. It is designed for a nominal voltage of 24 VDC. The module can be used to read in digital signals and to control actuators in safety-related applications up to PL e or SIL 3. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side high-side" variant (output type B) is required for actuators with reference potential (e.g. Enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20cSC2432
- X20cSC2432
- B&R
- The module is equipped with 2 safe digital inputs and 2 safe relay outputs. It is designed for a nominal voltage of 24 VDC. The module can be used to read digital signals and for floating control of actuators in safety-related applications up to PL e or SIL 3. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. Safety relays are installed in the module. The positively driven feedback contacts are evaluated internally by the module. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20cSD1207
- X20cSD1207
- B&R
- This module is equipped with 1 safe digital input for determining the velocity. Velocity information can be acquired from AB signals up to a maximum frequency of 7 kHz. The safe counter module is suitable for safely acquiring velocities for safety-related applications up to PL e or SIL 3. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20cSI4100
- X20cSI4100
- B&R
- This module is equipped with 4 safe digital inputs. It is designed for a nominal voltage of 24 VDC. The module can be used to read various digital signals in safety-related applications up to PL e or SIL 3. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20cSI9100
- X20cSI9100
- B&R
- This module is equipped with 20 safe digital inputs. It is designed for a nominal voltage of 24 VDC. The module can be used to read various digital signals in safety-related applications up to PL e or SIL 3. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20cSL8100
- X20cSL8100
- B&R
- The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3. In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed by the SafeLOGIC controller.
-
- B&R X20cSL8101
- X20cSL8101
- B&R
- The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3. In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed by the SafeLOGIC controller.
-
- B&R X20cSLX402
- X20cSLX402
- B&R
- The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3. In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed in conjunction with Automation Runtime on the standard CPU. In addition, SafeLOGIC-X products have the same I/O properties as the associated SafeIO products (X20SC0xxx).
-
- B&R X20cSLX410
- X20cSLX410
- B&R
- The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3. In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed in conjunction with Automation Runtime on the standard CPU. In addition, SafeLOGIC-X products have the same I/O properties as the associated SafeIO products (X20SIx1x0).
-
- B&R X20cSLX910
- X20cSLX910
- B&R
- The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3. In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed in conjunction with Automation Runtime on the standard CPU. In addition, SafeLOGIC-X products have the same I/O properties as the associated SafeIO products (X20SIx1x0).
-
- B&R X20cSO2530
- X20cSO2530
- B&R
- This module is equipped with 2 safe relay outputs. The module can be used for controlling floating actuators in safety-related applications up to PL e or SIL 3. Safety relays are installed in the module. The positively driven feedback contacts are evaluated internally by the module. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20cSO4110
- X20cSO4110
- B&R
- This module is equipped with 4 safe digital outputs. The nominal output current is 0.5 A. The module can be used for controlling actuators in safety-related applications up to PL e or SIL 3. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side low-side" variant (output type A) is limited to actuators without reference potential (e.g. relays, valves). Type A outputs have safety-related advantages since the actuator can be cut off in its connection cable in all error scenarios. Safe digital output channels provide protection against automatic restart when network errors occur and also using a current measurement for open circuit detection. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20cSO4120
- X20cSO4120
- B&R
- This module is equipped with 4 safe digital outputs. The nominal output current is 2 A. The module can be used for controlling actuators in safety-related applications up to PL e or SIL 3. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side low-side" variant (output type A) is limited to actuators without reference potential (e.g. relays, valves). Type A outputs have safety-related advantages since the actuator can be cut off in its connection cable in all error scenarios. Safe digital output channels provide protection against automatic restart when network errors occur and also using a current measurement for open circuit detection. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20cSO6300
- X20cSO6300
- B&R
- This module is equipped with 6 safe digital outputs. The nominal output current is 0.2 A. The module can be used for controlling actuators in safety-related applications up to PL e or SIL 3. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side high-side" variant (output type B) is required for actuators with reference potential (e.g. Enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20cSO6530
- X20cSO6530
- B&R
- This module is equipped with 6 safe relay outputs. The module can be used for controlling floating actuators in safety-related applications up to PL e or SIL 3. Safety relays are installed in the module. The positively driven feedback contacts are evaluated internally by the module. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20MK0223
- X20MK0223
- B&R
- X20 SafeKEY, 8 MB, for the X20SL81xx series, exclusively for mapp Safety, range of license functions determined via a package-based licensing model or via Technology Guarding in Automation Runtime
-
- B&R X20MKXXXX.XXX.XXX
- X20MKXXXX.XXX.XXX
- B&R
- Each solution is delivered exclusively as a set consisting of the SafeKEY and the activated licenses for the selected technology functions. Please note that a set can only be ordered if the combination was generated beforehand using the X20MK configurator.
-
- B&R X20SA4430
- X20SA4430
- B&R
- The module is equipped with 2 safe analog input pairs for current measurement. Each input pair has its own sensor power supply. The channels with their respective sensor supplies are electrically isolated from each other. It can be used to capture current signals in the range from 0.5 to 25 mA. The safe analog input module is suitable for safely acquiring current signals for safety-related applications up to PL e or SIL 3. This module is designed for X20 16-pin terminal blocks.
-
- B&R X20SC0402
- X20SC0402
- B&R
- The module is equipped with 4 safe digital inputs and 2 safe digital outputs. It is designed for a nominal voltage of 24 VDC. The module can be used to read in digital signals and to control actuators in safety-related applications up to PL e or SIL 3. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side high-side" variant (output type B) is required for actuators with reference potential (e.g. Enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.