- B&R X20SO6300
- X20SO6300
- B&R
- This module is equipped with 6 safe digital outputs. The nominal output current is 0.2 A. The module can be used for controlling actuators in safety-related applications up to PL e or SIL 3. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side high-side" variant (output type B) is required for actuators with reference potential (e.g. Enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20SO6530
- X20SO6530
- B&R
- This module is equipped with 6 safe relay outputs. The module can be used for controlling floating actuators in safety-related applications up to PL e or SIL 3. Safety relays are installed in the module. The positively driven feedback contacts are evaluated internally by the module. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20SP1130
- X20SP1130
- B&R
- This module is equipped with 1 safe digital output. The nominal output current is 10 A. The power supply module is used for the internal I/O power supply. A safe digital output channel is integrated in the module for cutting off the I/O power supply of connected X20 modules in safety-related applications up to PL e or SIL 3. The output is designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles.The "High-side-High-side" variant (output type B) is required for actuators with reference potential (e.g. Enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case.In addition, the instructions for switching off X20 potential groups must be observed.The safe digital output channel provides protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20SRT402
- X20SRT402
- B&R
- This reACTION Technology module is equipped with 4 high-speed safe digital inputs and 2 high-speed safe digital outputs. It is designed for a nominal voltage of 24 VDC. The module can be used to read in digital signals and to control actuators in safety-related applications up to PL e or SIL 3. Ultrafast reACTION Technology makes it possible to control internal I/O channels with cycle times down to 150 µs. All commands that can be used for reACTION programs are available as function blocks in special libraries (e.g. AsIORTI). Programming in compliance with IEC 61131-3 requirements takes place in the Function Block Diagram editor in Automation Studio. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of switching cycles. The "high-side high-side" variant (output type B) is required for actuators with reference potential (e.g. enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. The safe digital output modules are equipped with an error interlock in the event of network errors. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20SRT806
- X20SRT806
- B&R
- This reACTION Technology module is equipped with 8 high-speed safe digital inputs and 6 high-speed safe digital outputs. It is designed for a nominal voltage of 24 VDC. The module can be used to read in digital signals and to control actuators in safety-related applications up to PL e or SIL 3. Ultrafast reACTION Technology makes it possible to control internal I/O channels with cycle times down to 150 µs. All commands that can be used for reACTION programs are available as function blocks in special libraries (e.g. AsIORTI). Programming in compliance with IEC 61131-3 requirements takes place in the Function Block Diagram editor in Automation Studio. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of switching cycles. The "high-side high-side" variant (output type B) is required for actuators with reference potential (e.g. enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. The safe digital output modules are equipped with an error interlock in the event of network errors. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20SRT842
- X20SRT842
- B&R
- This reACTION Technology module is equipped with 8 high-speed safe digital inputs and 6 high-speed safe digital outputs. It is designed for a nominal voltage of 24 VDC. The module can be used to read in digital signals and to control actuators in safety-related applications up to PL e or SIL 3. Ultrafast reACTION Technology makes it possible to control internal I/O channels with cycle times down to 150 µs. All commands that can be used for reACTION programs are available as function blocks in special libraries (e.g. AsIORTI). Programming in compliance with IEC 61131-3 requirements takes place in the Function Block Diagram editor in Automation Studio. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of switching cycles. The "high-side low-side" variant (output type A) is limited to actuators without reference potential (e.g. relays, valves). Type A outputs have safety-related advantages since the actuator can be cut off in its connection cable in all error scenarios. The "high-side high-side" variant (output type B) is required for actuators with reference potential (e.g. enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. The safe digital output modules are equipped with an error interlock in the event of network errors. This module is designed for X20 12-pin terminal blocks.
-
- B&R X20ST4492
- X20ST4492
- B&R
- The module is equipped with 2 safe analog input pairs for J, K, N, S, R, C and T thermocouple sensors and 1 safe analog input pair for PT100/PT1000 resistance temperature measurement. The safe temperature module is suitable for safely acquiring temperatures for safety-related applications up to PL e or SIL 3. This module is designed for X20 16-pin terminal blocks.
-
- B&R X20TB52
- X20TB52
- B&R
- This terminal block is used to wire the X20 SafeIO modules with 12 connections.
-
- B&R X20TB5E
- X20TB5E
- B&R
- This terminal block is equipped with 2 integrated PT1000 sensors. It is therefore ideally suited for internal terminal temperature compensation. This terminal block is used to wire the safe X20 thermocouple modules with 16 connections.
-
- B&R X20TB5F
- X20TB5F
- B&R
- This terminal block is used to wire the X20 SafeIO modules with 16 connections.
-
- B&R X20TB72
- X20TB72
- B&R
- This terminal block is used to wire the 240 VAC X20 SafeIO modules with 12 connections.
-
- B&R X67SC4122.L12
- X67SC4122.L12
- B&R
- The module is equipped with 8 safe digital inputs and 4 safe digital outputs. They are designed for a nominal voltage of 24 VDC. The module can be used to read in digital signals and to control actuators in safety-related applications up to PL e or SIL 3. The node number switch for setting the X2X Link address is a unique feature. When modular machine configurations change, it is necessary, for example, to define specific module groups at a fixed address that is independent of the preceding modules in the line. All subsequent standard modules refer to this offset and use it automatically for addressing purposes. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side high-side" variant (output type B) is required for actuators with reference potential (e.g. Enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. Safe digital output channels provide protection against automatic restart when network errors occur.
-
- B&R X67SI8103
- X67SI8103
- B&R
- This module is equipped with 8 safe digital inputs. They are designed for a nominal voltage of 24 VDC. The module can be used to read various digital signals in safety-related applications up to PL e or SIL 3. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line.
-
- B&R X90CP174.48-S1
- X90CP174.48-S1
- B&R
- The heart of the X90 mobile system is a controller with a powerful ARM processor and up to 48 multifunction I/O channels. Basic features include connections for CAN, USB, Ethernet and the real-time POWERLINK bus system. The extremely robust die-cast aluminum housing provides space for up to 4 additional expansion boards. These make it possible to add I/O channels or interfaces as well as specific functions such as condition monitoring. The X90 mobile "Safety" variant is also equipped with a safe control system – also known as an X90 SafeLOGIC controller. All 48 multifunction I/Os included as standard can be used by both the standard variant and the X90 SafeLOGIC controller. Input and output signals can thus be read or operated by the standard variant and/or by the safe control system, depending on the wiring. The control lines required for this are linked by a logical AND in a safety-related manner, i.e. an output signal is only enabled if permitted by both the safety application and the standard application.
-
- B&R X90RO440.04-S1
- X90RO440.04-S1
- B&R
- The relay option board provides 4 additional safe relay outputs. Communication to the mainboard is made possible via X2X Link. The modules can be used for controlling floating actuators in safety-related applications up to PL e or SIL 3. Safety relays are installed within the module. The positively driven feedback contacts are evaluated within the module. The safe digital output modules have a start interlock on error in the event of network errors.
-
- Schneider Electric XACA4913
- XACA4913
- Schneider Electric
- Pendant Control Station, 4 Push Buttons, 1 Emergency Stop
-
- Schneider Electric XACD22P2241
- XACD22P2241
- Schneider Electric
- Pendant station with one 2 directional button and one emergency stop.
-
- Schneider Electric XALK178W3B140G
- XALK178W3B140G
- Schneider Electric
- Illuminated Ring with E Stop TTR Control Box, 24V 1NO 2NC, Harmony XB4 Series
-
- SICK XC40E-0303A0A0CBA0
- XC40E-0303A0A0CBA0
- SICK
- - Safety Light Curtains, Typical Scanning Range: ? 0 M
-
- SICK XC40E-0603A0A0CBA0
- XC40E-0603A0A0CBA0
- SICK
- - Safety Light Curtains, Typical Scanning Range: ? 0 M
-
- SICK XC40E-0603A0A0CBC0
- XC40E-0603A0A0CBC0
- SICK
- Safety Light Curtain
-
- SICK XC40E-0701A0A0CAB0
- XC40E-0701A0A0CAB0
- SICK
- - Safety Light Curtains, Typical Scanning Range: ? 0 M
-
- SICK XC40E-0903A0A0CBA0
- XC40E-0903A0A0CBA0
- SICK
- - Safety Light Curtains, Typical Scanning Range: ? 0 M
-
- SICK XC40E-1003A0A0CBC0
- XC40E-1003A0A0CBC0
- SICK
- - Safety Light Curtains, Typical Scanning Range: ? 0 M
-
- SICK XC40E-1203A0A0CBA0
- XC40E-1203A0A0CBA0
- SICK
- - Safety Light Curtains, Typical Scanning Range: ? 0 M