Safety Automation
Safety Automation
-
Part
Part Number
Manufacturer
Description
-
- Siemens 3TK2810-0A
- 3TK2810-0A
- Siemens
- SIRIUS safety relay Connecting cable length 1 meter for connecting the safe speed monitor 3TK2810-1 with the adapter for connection of encoders (3TK2810-1A/3TK2810-1B)
-
- Siemens 3TK2810-0BA01
- 3TK2810-0BA01
- Siemens
- SIRIUS safety relay safety-oriented Standstill monitoring 24 V DC, 45 mm screw terminal EC instantaneous: 3 NO + 1 NC EC delayed: 0 SC: 3 Auto-start Basic unit max. error category EN 954-1: 4 Maximum achievable PL according to EN 13849-1: Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2810-0BA02
- 3TK2810-0BA02
- Siemens
- SIRIUS safety relay safety-oriented Standstill monitoring 24 V DC, 45 mm Spring-type terminal EC instantaneous: 3 NO + 1 NC EC delayed: 0 SC: 3 Auto-start Basic unit max. error category EN 954-1: 4 Maximum achievable PL according to EN 13849-1: Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2810-0GA01
- 3TK2810-0GA01
- Siemens
- SIRIUS safety relay safety-oriented Standstill monitoring 230 V AC, 45 mm screw terminal EC instantaneous: 3 NO + 1 NC EC delayed: 0 SC: 3 Auto-start Basic unit max. error category EN 954-1: 4 Maximum achievable PL according to EN 13849-1: Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2810-0GA02
- 3TK2810-0GA02
- Siemens
- SIRIUS safety relay safety-oriented Standstill monitoring 230 V AC, 45 mm Spring-type terminal EC instantaneous: 3 NO + 1 NC EC delayed: 0 SC: 3 Auto-start Basic unit max. error category EN 954-1: 4 Maximum achievable PL according to EN 13849-1: Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2810-0JA01
- 3TK2810-0JA01
- Siemens
- SIRIUS safety relay safety-oriented Standstill monitoring 400 V AC, 45 mm screw terminal EC instantaneous: 3 NO + 1 NC EC delayed: 0 SC: 3 Auto-start Basic unit max. error category EN 954-1: 4 Maximum achievable PL according to EN 13849-1: Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2810-0JA02
- 3TK2810-0JA02
- Siemens
- SIRIUS safety relay safety-oriented Standstill monitoring 400 V AC, 45 mm Spring-type terminal EC instantaneous: 3 NO + 1 NC EC delayed: 0 SC: 3 Auto-start Basic unit max. error category EN 954-1: 4 Maximum achievable PL according to EN 13849-1: Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2810-1A
- 3TK2810-1A
- Siemens
- SIRIUS safety relay Adapter for 3TK2810-1 for connecting 15-pole encoders, Type: SIEMENS/HEIDENHAIN
-
- Siemens 3TK2810-1B
- 3TK2810-1B
- Siemens
- SIRIUS safety relay Adapter for 3TK2810-1 for connecting 25-pole encoders, Type: SIEMENS/HEIDENHAIN
-
- Siemens 3TK2810-1BA41
- 3TK2810-1BA41
- Siemens
- SIRIUS safety relay Safety-oriented Speed monitoring 24 V DC, 45 mm overall width Screw terminal EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical Auto-start/manual start Basic device Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2810-1BA41-0AA0
- 3TK2810-1BA41-0AA0
- Siemens
- SIRIUS safety relay Safety-oriented Speed monitoring 24 V DC, 45 mm overall width Screw terminal EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical NAMUR version Auto-start/manual start Basic device Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2810-1BA42
- 3TK2810-1BA42
- Siemens
- SIRIUS safety relay Safety-oriented Speed monitoring 24 V DC, 45 mm overall width Spring-type terminal EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical Auto-start/manual start Basic device Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2810-1BA42-0AA0
- 3TK2810-1BA42-0AA0
- Siemens
- SIRIUS safety relay Safety-oriented Speed monitoring 24 V DC, 45 mm overall width Spring-type terminal EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical NAMUR version Auto-start/manual start Basic device Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2810-1KA41
- 3TK2810-1KA41
- Siemens
- SIRIUS safety relay Safety-oriented Speed monitoring 110-240 V AC/DC, 45 mm overall width Screw terminal EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical Auto-start/manual start Basic device Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2810-1KA41-0AA0
- 3TK2810-1KA41-0AA0
- Siemens
- SIRIUS safety relay Safety-oriented Speed monitoring 110-240 V AC/DC, 45 mm overall width Screw terminal EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical NAMUR version Auto-start/manual start Basic device Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2810-1KA42
- 3TK2810-1KA42
- Siemens
- SIRIUS safety relay Safety-oriented Speed monitoring 110-240 V AC/DC, 45 mm overall width Spring-type terminal EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical Auto-start/manual start Basic device Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2810-1KA42-0AA0
- 3TK2810-1KA42-0AA0
- Siemens
- SIRIUS safety relay Safety-oriented Speed monitoring 110-240 V AC/DC, 45 mm overall width Spring-type terminal EC instantaneous: 2 NO EC delayed: 0 SC: 2 electrical NAMUR version Auto-start/manual start Basic device Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2820-1AJ20
- 3TK2820-1AJ20
- Siemens
- SIRIUS safety relay with relay enabling circuits (EC) 115V AC, 22.5 mm Screw terminal Basic device Auto-start, monitored start EC instantaneous: 3 NO EC delayed: 0 NO SC: 1NC max. error category EN 13849-1: 4 Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2820-1AL20
- 3TK2820-1AL20
- Siemens
- SIRIUS Safety Relay
-
- Siemens 3TK2820-1CB30
- 3TK2820-1CB30
- Siemens
- SIRIUS safety relay with relay enabling circuits (EC) 24 V AC/DC, 22.5 mm Screw terminal Basic device Auto-start, monitored start EC instantaneous: 3 NO EC delayed: 0 NO SC: 1NC max. error category EN 13849-1: 4 Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3
-
- Siemens 3TK2820-2CB30
- 3TK2820-2CB30
- Siemens
- SIRIUS Safety Relay
-
- Siemens 3TK2821-1CB30
- 3TK2821-1CB30
- Siemens
- SIRIUS safety relay with relay enabling circuits (EC) 24 V AC/DC, 22.5 mm Screw terminal EC instantaneous: 3 NO EC delayed: 0 NO SC: 1NC Autostart/manual start Basic device Maximum achieved SIL: 1, PL: c as expansion unit up to maximum achieved SIL: 3, PL: e
-
- Siemens 3TK2821-2CB30
- 3TK2821-2CB30
- Siemens
- SIRIUS safety relay with relay enabling circuits (EC) 24 V AC/DC, 22.5 mm Spring-type terminal EC instantaneous: 3 NO EC delayed: 0 NO SC: 1NC Autostart/manual start Basic device Maximum achieved SIL: 1, PL: c as expansion unit up to maximum achieved SIL: 3, PL: e
-
- Siemens 3TK2821-2CB30-ZW95
- 3TK2821-2CB30-ZW95
- Siemens
- SIRIUS safety relay with relay enabling circuits (EC) 24 V AC/DC, 22.5 mm Spring-type terminal Packing quantity = 113 units
-
- Siemens 3TK2821-2CB30-ZW96
- 3TK2821-2CB30-ZW96
- Siemens
- SIRIUS safety relay with relay enabling circuits (EC) 24 V AC/DC, 22.5 mm Spring-type terminal Multi-unit packaging Packing quantity = 52 units