-
- Part Number
- Description
- Availability
-
- X20AC0SC1
- X20 terminal locking clip and tag holder for plain text tag
- Available
-
- X20AC0SC1.0100
- X20 terminal locking clip and tag holder for plain text tag, package of 100 pcs.
- Available
-
- X20AC0SF7.0010
- X20 shielding bracket 66 mm 10 pcs.
- Available
-
- X20AC0SF9.0010
- X20 shielding bracket 88 mm 10 pcs.
- Available
-
- X20AC0SG1.0010
- X20 cable shield grounding clamp, package of 10 pcs.
- Available
-
- X20AC0SG1.0100
- X20 cable shield grounding clamp, package of 100 pcs.
- Available
-
- X20AC0SH1
- X20 plain text tag
- Available
-
- X20AC0SH1.0100
- X20 plain text tag, package of 100 pcs.
- Available
-
- X20AC0SH2.0010
- X20 PLC labels, 10 pcs.
- Available
-
- X20AC0Sl1
- X20 end cover plate, left
- Available
-
- X20AC0SL1.0010
- X20 end cover plate, left, package of 10 pcs.
- Available
-
- X20AC0SR1
- X20 end cover plate, right
- Available
-
- X20AC0SR1.0010
- X20 end cover plate, right, package of 10 pcs.
- Available
-
- X20ACEMTB1
- The accessory package for X20 Embedded CPUs includes the following components:
- Available
-
- X20AI1744
- This module works with both 4-wire and 6-wire strain gauge load cells. The concept applied by the module requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero point offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature.
- Available
-
- X20AI1744-10
- This module works with both 4-wire and 6-wire strain gauge load cells. The concept applied by the module requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero point offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature.
- Available
-
- X20AI1744-3
- This module works with both 4-wire and 6-wire strain gauge load cells. The concept applied by the module requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero point offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature.
- Available
-
- X20AI2222
- The module is equipped with 2 inputs with 13-bit (including sign) digital converter resolution. It can be used to capture voltage signals in the range from ±10 V. This module is designed for X20 6-pin terminal blocks. If needed (e.g. for logistical reasons), the 12-pin terminal block can also be used.
- Available
-
- X20AI2237
- The module is equipped with 2 voltage measurement inputs with 16-bit digital converter resolution. Each voltage input has its own sensor supply. The two channels with their respective sensor supplies are electrically isolated from each other.
- Available
-
- X20AI2322
- The module is equipped with 2 inputs with 12-bit digital converter resolution. It is possible to select between the two current ranges 0 to 20 mA and 4 to 20 mA. This module is designed for X20 6-pin terminal blocks. If needed (e.g. for logistical reasons), the 12-pin terminal block can also be used.
- Available
-
- X20AI2437
- The module is equipped with 2 current measurement inputs with 16-bit digital converter resolution. Each current measurement input has its own sensor supply. The two channels with their respective sensor supplies are electrically isolated from each other. The user can select between the two measurement ranges 4 to 20 mA and 0 to 25 mA.
- Available
-
- X20AI2438
- The module is equipped with 2 current measurement inputs with 16-bit digital converter resolution. It supports the HART communication standard for data transfer, parameter configuration and diagnostics. Each current measurement input has its own sensor supply. The two channels with their respective sensor supplies are electrically isolated from each other. The user can select between the two measurement ranges 4 to 20 mA and 0 to 25 mA.
- Available
-
- X20AI2622
- The module is equipped with 2 inputs with 13-bit (including sign) digital converter resolution. It is possible to select between the current and voltage signal using different terminals. This module is designed for X20 6-pin terminal blocks. If needed (e.g. for logistical reasons), the 12-pin terminal block can also be used.
- Available
-
- X20AI2632
- The module is equipped with 2 inputs with 16-bit digital converter resolution. It is possible to select between the current and voltage signal using different terminals. This module is designed for X20 6-pin terminal blocks. If needed (e.g. for logistical reasons), the 12-pin terminal block can also be used.
- Available
-
- X20AI2632-1
- The module is equipped with 2 inputs with 16-bit digital converter resolution. It is possible to select between the current and voltage signal using different terminals. This module is designed for X20 6-pin terminal blocks. If needed (e.g. for logistical reasons), the 12-pin terminal block can also be used.
- Available
Trusted by…
Trusted by industry leaders
Trusted by industry leaders