- Part Number
- Description
- Availability
-
- X20cIF1041-1
- The interface module is equipped with a CANopen interface. This allows third-party components to be integrated in the B&R system and makes it possible to quickly and easily transfer data in both directions. The interface module can be operated in X20 CPUs or in the expandable POWERLINK bus controller X20BC1083.
- Available
-
- X20cIF1061-1
- The interface module is equipped with a PROFIBUS DP V1 interface. This allows third-party components to be integrated in the B&R system and makes it possible to quickly and easily transfer data in both directions. The interface module can be operated in X20 CPUs or in the expandable POWERLINK bus controller X20BC1083.
- Available
-
- X20cIF1063-1
- The interface module is equipped with a PROFIBUS DP V1 interface. This allows the B&R system (I/O modules, POWERLINK, etc.) to be connected to systems from other manufacturers and makes it possible to quickly and easily transfer data in both directions. The interface module can be operated in X20 CPUs or in the expandable POWERLINK bus controller X20BC1083.
- Available
-
- X20cIF1072
- The interface module can be used to expand the X20 CPU for specific applications. It is equipped with a CAN bus interface.
- Available
-
- X20cIF1082-2
- The interface module can be used to expand the X20 CPU for specific applications. It is equipped with an POWERLINK interface. The interface has two RJ45 sockets. Both connections lead to an integrated hub. This makes it easy to create daisy-chain connections using POWERLINK.
- Available
-
- X20cIF10D1-1
- The interface module is equipped with an EtherNet/IP scanner interface. This allows third-party components to be integrated in the B&R system and makes it possible to quickly and easily transfer data in both directions. The interface module can be operated in X20 CPUs or in the expandable POWERLINK bus controller X20BC1083. The interface is equipped with 2 RJ45 connections. Both connections result in an integrated switch. This makes it easy to implement daisy chain cabling.
- Available
-
- X20cIF10D3-1
- The interface module is equipped with an EtherNet/IP adapter interface. This allows the B&R system (I/O modules, POWERLINK, etc.) to be connected to systems from other manufacturers and makes it possible to quickly and easily transfer data in both directions. The interface module can be operated in X20 CPUs or in the expandable POWERLINK bus controller X20BC1083. The interface is equipped with 2 RJ45 connections. Both connections result in an integrated switch. This makes it easy to implement daisy chain cabling.
- Available
-
- X20cIF10D3-2
- X20 Interface Module Coated
- Available
-
- X20cIF10E3-1
- The interface module is equipped with a PROFINET IO device interface. This allows the B&R system (I/O modules, POWERLINK, etc.) to be connected to systems from other manufacturers and makes it possible to quickly and easily transfer data in both directions. The interface module can be operated in X20 CPUs or in the expandable POWERLINK bus controller X20BC1083. The interface is equipped with 2 RJ45 connections. Both connections result in an integrated switch. This makes it easy to implement daisy chain cabling.
- Available
-
- X20cIF10X0
- Interface module for the operation of redundant CPUs.
- Available
-
- X20cIF2181-2
- The interface module is used to expand the X20 CPU for specific applications. It is equipped with an POWERLINK interface. POWERLINK is a standard protocol for Fast Ethernet equipped with hard real-time characteristics. The POWERLINK Standardization Group (EPSG, see www.ethernet-powerlink.org) ensures its openness and continual development. Systems with redundant cabling can be implemented easily using POWERLINK. Unlike ring redundancy, cable redundancy does not require cable looping, which can sometimes be problematic. This allows the creation of all types of tree structures. When using a device with the link selector function, data is always transferred via the highest quality network lines. The link selector function is integrated in the X20IF2181-2 module.
- Available
-
- X20CM0985
- The module has a compact size and combines a power measurement module that has special features with a synchronization unit that is able to meet all demands. The measurement unit's 3 current inputs are suitable for both X: 1 A and X: 5 A current transformers. Overcurrent resistance and the high resolution of the measurement unit round off its features. For the voltage inputs, the value range can be configured between 480 VAC and 120 VAC. The area of use includes 4-wire AC networks with a phase voltage up to 480 VAC and 3-wire systems, whereas L2 can be grounded (V-connection). The module can also handle Aron measuring circuits. The resulting measured values include the pure phase current; line-to-line voltage or phase voltage; the effective, reactive and apparent power parts; the mains frequency; the power factor and much more. In addition, peak values and energy meters are stored on the module in nonvolatile memory. Depending on the configuration, it is also possible to use a digital output as a pulse encoder for an external energy meter. The synchronization unit doesn't just take the phasing and phase voltage into consideration; integrated intelligence also monitors the rate of change and other parameters, allowing them to influence when the synchronization output is switched. It is also possible to monitor a generator using a large number of additional conditions. A total of 4 voltage inputs provide substantial overall flexibility. Monitoring functions expand the features of the module. Dependent overcurrent monitoring is included, which utilizes the thermal capacity of the motor/generator to allow short overloads while still providing full protection. The dependent, delayed imbalanced load monitoring used to protect three-phase generator and three-phase networks from imbalanced load can be adapted to the characteristics of different generator types using parameters while taking their special thermal time constants into account.
- Available
-
- X20CM0985-02
- The module combines a power measurement module with special features in a compact footprint together with a synchronizing unit that meets all requirements. The measurement unit is 3 current inputs are suitable for both X: 1 A and X: 5 A current transformers. Overcurrent resistance and the high resolution of the unit of measurement round off its features. For the voltage inputs, the value range can also be configured between 480 VAC and 120 VAC without any loss in converter resolution. The area of application includes 4-wire AC power systems with a line-to-line voltage up to 480 VAC and 3-wire systems, where L2 can be grounded (V circuit). In addition, the module masters the measuring principle of the Aron circuit. The resulting measured values range from the pure phase current and line-to-line or phase voltage to active, reactive and apparent power components, mains frequency, power factor and much more. In addition, peak values and energy meters are stored on the module in nonvolatile memory. Depending on the configuration, it is also possible to use a digital output as a pulse encoder for an external energy meter. The synchronization unit does not just take the phasing and phase voltage into consideration; integrated intelligence also monitors the rate of change and other parameters, allowing them to influence when the synchronization output is switched. It is also possible to monitor a generator using a large number of additional conditions. A total of 4 voltage inputs provide substantial overall flexibility. Monitoring functions expand the features of the module. Dependent overcurrent monitoring is included, which utilizes the thermal capacity of the motor/generator to allow short overloads while still providing full protection. The dependent, delayed imbalanced load monitoring used to protect three-phase generator and three-phase networks from imbalanced load can be adapted to the characteristics of different generator types using parameters while taking their special thermal time constants into account.
- Available
-
- X20CM0985-1
- The module has a compact size and combines a power measurement module that has special features with a synchronization unit that is able to meet all demands. The measurement unit's 3 current inputs are suitable for both X: 1 A and X: 5 A current transformers. Overcurrent resistance and the high resolution of the measurement unit round off its features. For the voltage inputs, the value range can be configured between 480 VAC and 120 VAC. The area of use includes 4-wire AC networks with a phase voltage up to 480 VAC and 3-wire systems, whereas L2 can be grounded (V-connection). The module can also handle Aron measuring circuits. The resulting measured values include the pure phase current; line-to-line voltage or phase voltage; the effective, reactive and apparent power parts; the mains frequency; the power factor and much more. In addition, peak values and energy meters are stored on the module in nonvolatile memory. Depending on the configuration, it is also possible to use a digital output as a pulse encoder for an external energy meter. The synchronization unit doesn't just take the phasing and phase voltage into consideration; integrated intelligence also monitors the rate of change and other parameters, allowing them to influence when the synchronization output is switched. It is also possible to monitor a generator using a large number of additional conditions. A total of 4 voltage inputs provide substantial overall flexibility. Monitoring functions expand the features of the module. Dependent overcurrent monitoring is included, which utilizes the thermal capacity of the motor/generator to allow short overloads while still providing full protection. The dependent, delayed imbalanced load monitoring used to protect three-phase generator and three-phase networks from imbalanced load can be adapted to the characteristics of different generator types using parameters while taking their special thermal time constants into account.
- Available
-
- X20CM1201
- The module can be used to configure and carry out simple movements. For this purpose, the module has one AB encoder input and a total of 8 digital channels. Four of them are inputs, and the other 4 can be set as either an input or an output. Various output bit patterns are stored directly in the module. The module is perfectly suited for easy to create drive control tasks for program and event controlled motor movements. Feed movements using drives with 2 speeds and forward/reverse movement are created easily and efficiently.
- Available
-
- X20CM1941
- The module is equipped with a resolver input and a configurable ABR output.
- Available
-
- X20CM2821
- I/O Module, 4 digital inputs, 2 digital outputs, 24V DC.
- Available
-
- X20CM4323
- The module has digital outputs for connecting electromechanical loads (e.g. valves and relays) and additional functions such as edge generation. With a resolution down to 125 ns, the module makes it possible to set switching operations at exactly specified moments. The following operating modes can optionally be supplemented with PWM functionality: Additional functions:
- Available
-
- X20CM4800X
- This analog vibration measurement module can be operated with a configurable sampling rate of 200 to 50000 samples/second. The module has 4 input channels, which are transmitted with configurable 16-, 24- or 32-bit data resolution. Data is transferred for each channel via a separate Flatstream.
- Available
-
- X20CM4810
- This compact module provides a system for measuring and analyzing vibrations for use in applications such as condition monitoring for machinery and equipment. The measurement unit consists of 4 vibration inputs with 24-bit converter resolution and a sampling frequency of 51.562 kHz. Each of the inputs has a separately activated constant current source to supply IEPE sensors. Signal conditioning algorithms integrated in the module include configurable high and low-pass filters, an envelope curve generator and a Fourier transform, among many others. Various characteristic values and configurable frequency bands are available to ensure seamless signal evaluation. The module-internal calculation minimizes the load on the bus and PLC. Whether used for traditional condition monitoring or as a means of process optimization, the maximum evaluable frequency of 10 kHz and maximum frequency resolution of under 63 mHz make it suitable for almost any application. If desired, it can also be used as a standard input module. The ability to upload all values in the time and frequency domain also allow measurements to be evaluated externally or archived.
- Available
-
- X20CM8281
- The module is a universal mixed module. On this module, digital I/O and analog I/O are combined. A current or voltage signal can be used for the analog I/O as desired. Counter functions on two of the digital inputs expand the range of use.
- Available
-
- X20CM8323
- The module has digital outputs for switching electromechanical loads (e.g. valves, relays) and additional functions.
- Available
-
- X20cMM2436
- The motor bridge module is used to control 2 DC motors with a nominal voltage of 24 to 39 VDC ±25% at a nominal current up to 3 A. The module can be reconfigured and used in current controller mode for controlling inductive loads. The module is also equipped with 4 digital inputs, which can be used as incremental counters. Each motor is controlled with a full-bridge (H-bridge). This enables the motors to be moved in both directions.
- Available
-
- X20CMR010
- The module is designed for measuring ambient conditions in the control cabinet as well as recording operating hours and power-on cycles. In addition, the module offers the option of storing user data directly on the module and supports blackout mode. Measuring and evaluating ambient conditions The ambient conditions are continuously evaluated by the module. The duration in which individual parameters are within certain ranges is stored internally. This makes it possible, for example, to determine how long the system remained in a certain temperature range. The histograms recorded by the module can be read out by the user. Internal module memory for user data With 512 kB nonvolatile user memory (flash), data from the application can be saved directly on the module and also read back from the module. The data is therefore retained after the module or CPU is restarted and remains with the module in the event that the module is connected to another machine or system, for example. Data retention is maintenance-free – without batteries. Blackout mode The integrated blackout mode ensures that module functionality is maintained even in the event of network failure.
- Available
-
- X20CMR011
- The module is designed for measuring ambient conditions in the control cabinet as well as recording operating hours and power-on cycles. In addition, the module offers the option of storing user data directly on the module, is equipped with inputs/outputs and supports blackout mode. Measuring and evaluating ambient conditions The ambient conditions are continuously evaluated by the module. The duration in which individual parameters are within certain ranges is stored internally. This makes it possible, for example, to determine how long the system remained in a certain temperature range. The histograms recorded by the module can be read out by the user. Internal module memory for user data With 512 kB nonvolatile user memory (flash), data from the application can be saved directly on the module and also read back from the module. The data is therefore retained after the module or CPU is restarted and remains with the module in the event that the module is connected to another machine or system, for example. Data retention is maintenance-free – without batteries. Inputs/Outputs The module is equipped with 2 inputs for Pt1000 temperature sensors, 2 digital inputs (24 VDC) and 1 digital output (24 VDC). Blackout mode The integrated blackout mode ensures that module functionality is maintained even in the event of network failure.
- Available