- Part Number
- Description
- Availability
-
- X67IF1121-1
- Serial interfaces (barcode scanners for example) are often scattered throughout systems. This interface module from the remote X67 system is the optimal choice for this area of application: RS232 and RS485/RS422 connection options directly where they are needed, distributed on the machine or system. In addition, there are digital inputs and outputs on the same module so that corresponding 24 V sensors/actuators can also be connected.
- Available
-
- X67MM2436
- This motor bridge module is used to control 2 DC motors with a nominal voltage of 24 to 38.5 VDC ±25% at a nominal current up to 3 A. The module can be reconfigured and used in current controller mode for controlling inductive loads. The module is also equipped with 6 digital inputs, which can be used as incremental counters. Each motor is controlled with a full-bridge (H-bridge). This enables the motors to be moved in both directions.
- Available
-
- X67PS1300
- This system supply module converts the 24 VDC I/O supply voltage into the electrically isolated X2X Link power supply. The module provides 15 W of output power for additional X67 modules on the bus.
- Available
-
- X67SC4122.L12
- The module is equipped with 8 safe digital inputs and 4 safe digital outputs. They are designed for a nominal voltage of 24 VDC. The module can be used to read in digital signals and to control actuators in safety-related applications up to PL e or SIL 3. The node number switch for setting the X2X Link address is a unique feature. When modular machine configurations change, it is necessary, for example, to define specific module groups at a fixed address that is independent of the preceding modules in the line. All subsequent standard modules refer to this offset and use it automatically for addressing purposes. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side high-side" variant (output type B) is required for actuators with reference potential (e.g. Enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. Safe digital output channels provide protection against automatic restart when network errors occur.
- Available
-
- X67SI8103
- This module is equipped with 8 safe digital inputs. They are designed for a nominal voltage of 24 VDC. The module can be used to read various digital signals in safety-related applications up to PL e or SIL 3. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line.
- Available
-
- X67SM2436
- The stepper motor module is used to control up to 2 stepper motors with a nominal voltage of 24 to 38.5 VDC ±25% at a motor current up to 3 A (5 A peak). In addition, this module has 6 digital inputs that can be used as limit switches or encoder inputs. Due to the individual adjustment of the coil currents, the motor is only operated with the current it actually needs. This simplifies the selection of the available motors and prevents unnecessary heating. Because this affects energy consumption and thermal load, the effects are positive on the service life of the complete system. Complete flexibility is achieved through the use of independently adjustable holding, boost and nominal current values. The current for microsteps is automatically adjusted to the configured current values. The automatic motor identification system is an enormous help during standstills. The stepper motor modules can identify the connected motors using their coil characteristics and generate feedback in the form of an analog value. This makes it possible to detect not only wiring errors, but also incorrect motor types being used mistakenly. A stall detection mechanism is integrated to analyze the motor load. Detection of the stall is defined via a configurable threshold. This allows an overload or motor standstill to be detected precisely in many different types of applications.
- Available
-
- X67SM2446-1
- The stepper motor module is used to control stepper motors with a nominal voltage of 24 to 48 VDC (±25%) at a motor current up to 4 A (8 A peak). In addition, this module has 6 digital inputs that can be used as limit switches or encoder inputs. Due to the individual adjustment of the coil currents, the motor is only operated with the current it actually needs. This simplifies the selection of the available motors and prevents unnecessary heating. Because this affects energy consumption and thermal load, the effects are positive on the service life of the complete system. Complete flexibility is achieved through the use of independently adjustable holding, maximum and nominal current values. The current for microsteps is automatically adjusted to the configured current values. In addition, the module contains a sensorless, load-dependent current control. Depending on the operating situation and load, the module controls the current downwards. Energy savings up to 75% are possible in this way. The automatic motor identification system is an enormous help during standstills. The stepper motor modules can identify the connected motors using their coil characteristics and generate feedback in the form of an analog value. This makes it possible to detect not only wiring errors, but also incorrect motor types being used mistakenly. "Stall detection" is integrated to analyze the motor load. Detection of the stall is defined via a configurable threshold. This allows an overload or motor standstill to be detected precisely in many different types of applications.
- Available
-
- X67SM4320
- This stepper motor module is used to control up to 4 stepper motors with a rated voltage of 24 VDC ±25% at a motor current up to 1 A (1.5 A peak). By individually adjusting the coil currents, the motor is only operated with the current it actually needs. This simplifies selection of the available motors and prevents unnecessary heating. Because the latter reduces energy consumption and thermal load, the effects are positive on the lifespan of the complete system. Complete flexibility is achieved by using the values for holding current, boost current and continuous current, which are completely independent of each other. The current for microsteps is automatically adjusted to the configured current values. A stall detection mechanism is integrated to analyze the motor load. The stall is recognized using a configurable threshold. This allows an overload or motor standstill to be detected precisely in many different types of applications.
- Available
-
- X67UM1352
- This module enables the remote connection of a force gauge using a strain gauge with a converter resolution of up to 24-bit. The data rate can be set from 0.26 ms to 100 ms. This module concept requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero point offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature. The module is also equipped with 4 digital inputs and 2 digital outputs.
- Available
-
- X90AC-BB.12-00
- X90 mobile 120, breakout box template and cable adapter for X90AC-BB.17-00 breakout box, for development and tests
- Available
-
- X90AC-BB.17-00
- X90 mobile 170, breakout box for development and tests
- Available
-
- X90AC-RP-SC-00
- X90 service access cap replacement part set 1x silicone profile gasket, orange 1x silicone profile gasket, yellow 1x service access cap with ejection function
- Available
-
- X90AISG0.02-00
- This module is equipped with 2 inputs for evaluating full-bridge strain gauges and works with 4-wire and 6-wire strain gauge load cells. The concept applied by the module requires compensation in the measurement system. This compensation eliminates the absolute uncertainty in the measurement circuit, such as component tolerances, effective bridge voltage or zero offset. The measurement precision refers to the absolute (compensated) value, which will only change as a result of changes in the operating temperature. Communication to the mainboard is made possible via X2X Link.
- Available
-
- X90AO410.04-00
- The AO option board offers 4 additional analog outputs, each of which can be configured as a current or voltage output. Communication to the mainboard is made possible via X2X Link. The pins in use can also be used as digital inputs; it is possible to toggle them between sink mode and source mode.
- Available
-
- X90AO410.08-00
- The AO option board offers 8 additional analog outputs, each of which can be configured as a current or voltage output. Communication to the mainboard is made possible via X2X Link. The pins in use can also be used as digital inputs; it is possible to toggle them between sink mode and source mode.
- Available
-
- X90AT910.04-00
- The AT option board offers 4 additional channels that can be used for current, voltage or temperature measurement. It is also possible to use the analog inputs as PWM signal outputs or digital inputs (with toggling between sink mode and source mode). Communication to the mainboard is made possible via X2X Link.
- Available
-
- X90AT910.08-00
- The AT option board offers 8 additional channels that can be used for current, voltage or temperature measurement. It is also possible to use the analog inputs as PWM signal outputs or digital inputs (with toggling between sink mode and source mode). Communication to the mainboard is made possible via X2X Link.
- Available
-
- X90BC124.32-00
- Bus controller module X90BC124.32-00 is a configurable CANopen slave module for sensor and actuator management. 32 multifunction inputs and outputs are available for a wide range of tasks. The robust die-cast aluminum housing enables use in harsh ambient conditions.
- Available
-
- X90CA100.02-00
- X90 mobile 170, wiring harness starter set for X90CP17x, 2 m, for CMC header
- Available
-
- X90CA124.02-00
- X90 mobile 120, wiring harness starter set for X90BC124, 2 m, for CMC header
- Available
-
- X90CM480.04-00
- Option board X90CM480.04-00 provides a compact system for measuring and analyzing vibrations for use in applications such as condition monitoring for machinery and equipment. The measurement unit consists of 4 vibration inputs with 24-bit converter resolution and a sampling frequency of 51.562 kHz. Each of the inputs has a separately switchable constant current source for supplying power to the IEPE sensors. The option board integrates numerous algorithms for signal processing. These include configurable high and low pass filters, envelope generation and Fourier transformation. Various parameters and configurable frequency bands are available to ensure seamless signal evaluation. The module performs calculations internally to minimize the load on the bus and CPU. Whether used for traditional condition monitoring or as a means of process optimization, the maximum evaluable frequency of 10 kHz and maximum frequency resolution of under 63 mHz make the option board suitable for almost any application. If desired, the option board can also be used as a standard input module. The ability to upload all values in the time and frequency domain also allows measurements to be evaluated externally or archived.
- Available
-
- X90CP172.24-00
- The heart of the X90 mobile system is a controller with a powerful ARM processor and up to 24 multifunction I/O channels. Basic features include interfaces for CAN, USB and Ethernet. The extremely robust die-cast aluminum housing provides space for up to 4 additional expansion boards. These make it possible to use additional I/O channels or interfaces as well as specific functions such as condition monitoring.
- Available
-
- X90CP172.48-00
- The heart of the X90 mobile system is a controller with a powerful ARM processor and up to 48 multifunction I/O channels. Basic features include interfaces for CAN, USB and Ethernet. The extremely robust die-cast aluminum housing provides space for up to 4 additional expansion boards. These make it possible to use additional I/O channels or interfaces as well as specific functions such as condition monitoring.
- Available
-
- X90CP174.24-00
- The heart of the X90 mobile system is a controller with a powerful ARM processor and up to 24 multifunction I/O channels. Basic features include interfaces for CAN, USB, Ethernet and the real-time POWERLINK bus system. The extremely robust die-cast aluminum housing provides space for up to 4 additional expansion boards. These make it possible to add I/O channels or interfaces as well as specific functions such as condition monitoring.
- Available
-
- X90CP174.48-00
- The heart of the X90 mobile system is a controller with a powerful ARM processor and up to 48 multifunction I/O channels. Basic features include connections for CAN, USB, Ethernet and the real-time POWERLINK bus system. The extremely robust die-cast aluminum housing provides space for up to 4 additional expansion boards. These make it possible to add I/O channels or interfaces as well as specific functions such as condition monitoring.
- Available