- Part Number
- Description
- Availability
-
- 130B1208
- 1xMCB 107 24V DC coat w. mount. brackets Connect an external DC supply to keep the control section and any installed option alive during power failure. Enables full operation of the LCP (including the parameter setting) and all installed options without connection to mains.
- Available
-
- 130B1210
- VLT Relay Option MCB 105, coated Relay extension for FC 100 and FC 300. Extension with 3 additional load relays (changeover contacts), easy to retrofit thanks to modular technology. Painted version for harsh environments, easy to retrofit thanks to modular technology. Max. Load 240V AC (resistive): 2 A Max. Load 240V AC (Cos Phi 0.4): 0.2 A Max. Load 24V DC (ohmic): 1 A Max. Load 24V DC (inductive): 0.1 A
- Available
-
- 130B1212
- VLT General Purpose I/O MCB 101, ctd MCB 101 - Advanced I / O option Expands the number of freely programmable Control inputs and outputs around the following I / Os: - 3 digital inputs opto-decoupled 0 - 24 V. - 2 analog inputs 0 - 10 V. - 2 digital outputs NPN / PNP switchable 24 V - 1 analog output 0/4 - 20 mA with reinforced coating
- Available
-
- 130B1218
- VLT Ext. Cascade Contr. MCO 101, ctd Upgrades the built-in cascade controller to control multiple pumps - easy to mount via plug ‘n’ play - More advanced pump control in master / follower mode - Up to 6 pumps in standard cascade control - Up to 5 pumps in master / follower setup This MCO option, sits in a B option space. Danfoss can offer help with programming / setting up MCO options. Contact Danfoss for advice and prices. Product group: R
- Available
-
- 130B1219
- VLT EtherNet IP MCA 121, coated EtherNet/IP extends commercial off-the-shelf Ethernet to the Common Industrial Protocol (CIP) – the same upper-layer protocol and object model found in DeviceNet. Built-in high-performance switch enabling line-topology, and eliminating the need for external switches. Device Level Ring (DLR) topology for higher system availability. Based on CIP, makes the reuse of PLC program possible when migrating from DeviceNet to EtherNet/IP. Built-in web server provides remote diagnosis and reading out of basic drive parameters. E-mail notification provides fast access to warnings or alarm information. Unicast and Multicast communication for improved network utilization. Certified by ODVA for fulfilment of the newest standard.
- Available
-
- 130B1220
- VLT Safe PLC I/O MCB 108, coated Increases security and helps you meet requirement security levels - VLT AutomationDrive FC 302 has a safety input based on a single pole 24 V DC input - Security in a cost-effective way Possibility of connection to two conductor safety system Possibility to interrupt on the plus or minus side without disturbing the sensor signal
- Available
-
- 130B1227
- VLT Resolver Input MCB 103, coated Resolver extension for FC 300. Enables the connection of the following Resolver types: Input voltage: 4..8 Vrms Input frequency: 2.5..15 kHz Number of resolver poles: 2 or 4
- Available
-
- 130B1234
- VLT Motion Control MCO 305, coated Integrated and programmable motion controller for VLT AutomationDrive FC 301 and FC 302 - Adds additional functionality and flexibility as it is a freely programmable module - Optimized for all types of positioning and synchronization applications - Make your own program specially adapted to your application Contains: - synchronization (electronic shaft), positioning and electronic cam control - 2 inputs support both stepwise and absolute encoders - 1 encoder output (virtual master function) 10 digital inputs - 8 digital outputs - Sends and receives data via fieldbus interface (requires fieldbus option) - PC software for programming and commissioning Remember to order the Mounting kit if the above MCO option is required retrofitted. 130B7530 - Mounting kit for enclosures A2 and A3 130B7531 - Mounting kit for MCO Option, together with MCB 113, in enclosures A2 and A3 130B1413 - Mounting kit for enclosure B3 130B1414 - Mounting kit for MCO Option, together with MCB 113, in enclosure B3 130B7532 - Mounting kit for enclosure A5 130B7533 - Mounting kit for all enclosures B, C, D, E and F (B3 excepted) Danfoss MCO options are not sold without prior advice. Danfoss can offer help with programming / setting up MCO options. Contact Danfoss for advice and prices. Product group: R
- Available
-
- 130B1235
- VLT PROFINET MCA 120, coated MCA 120 PROFINET interface With reinforced coating (class 3C3 / IEC 60721-3-3) -Supports operation on PROFINET network with extensive characteristics -DCP support for easy setting u. Communication parameters via the PLC -on Board web-Page with Drive Status -parameterization with the MCT10 software - 2-port version, reduced external hardware
- Available
-
- 130B1243
- VLT Analog I/O Option MCB 109, coated I / O extension for FC 100, easy to retrofit thanks to modular technology. Analog inputs / outputs galvanically isolated. Expands the analog inputs / outputs by: 3 analog inputs: 0 ... 10V / Pt1000 / Ni1000 3 analog outputs: 0 ... 10V Time switch (RTC backup): lithium cell for 10 years
- Available
-
- 130B1244
- VLT BACnet MCA 109, coated A. Device profile: Application-Specific-Controller (B-ASC) Supported objects: Analog Input, Analog Output, Analog Value, Binary Input, binary output, Binary Value, Device, Multi-State Output, Notification Class Protocol: Building automation world standard ISO 16484-5 Data Link Layer: MS / TP 9600, 19200, 38400, 76800 Data sharing: ReadProperty-B, DS-RP-B ReadPropertyMultiple-B, DS-RPM-B WriteProperty-B, DS-WP-B WritePropertyMultiple-B, DS-WPM-B Alarm and Notification Internal-B, AE-N-I-B Event Notification: ACK-B, AE-ACK-B Information-B, AE-INFO-B Device and Network Dynamic Device Binding-A, DM-DDB-A Management: Dynamic Device Binding-B, DM-DDB-B
- Available
-
- 130B1245
- VLT PROFIBUS Converter MCA 113, ctd Ensures easy and quick replacement of VLT 3000 to VLT AutomationDrive. VLT 3000 can then be replaced by VLT AutomationDrive or - the system Can be expanded without costly changes to the PLC program - Flexible investment as it is easy to remove and replace option when upgrading to another fieldbus Product group: R1
- Available
-
- 130B1246
- VLT PROFIBUS Converter MCA 114, ctd A special version of the PROFIBUS options that emulates VLT 5000 commands in the VLT AutomationDrive. The VLT 5000 can be replaced by the VLT AutomationDrive, or an existing system can be expanded without costly change of the PLC program. For upgrade to a different fieldbus, the installed converter is easily removed and replaced with a new option. This secures the investment without losing flexibility. The option supports DPV1.
- Available
-
- 130B1252
- VLT Synchronizing Ctrl. MCO 350, ctd MCO 350 - synchronous controller Based on the MCO 305 prefabricated controller for Synchronization tasks. The adjustment takes place through parameter settings. Specific Programming skills are not required. - 2 encoder inputs, both for incremental as well as absolute encoder - 1 encoder output (virtual master function) - 10 additional digital inputs - 8 additional digital outputs - fieldbus Communication (requires fieldbus card) with reinforced coating
- Available
-
- 130B1253
- VLT Position Controller MCO 351, ctd Extends the functional characteristics of the frequency converter in positioning applications - Direct positioning via fieldbus, relative positioning, absolute positioning and touch probe positioning - End stop handling (software and hardware) - Mechanical brake handling (programmable hold delay) Error handling - Jog speed / manual operation - None for programming, as it is pre-programmed Remember to order the Mounting kit if the above MCO option is required retrofitted. 130B7530 - Mounting kit for enclosures A2 and A3 130B7531 - Mounting kit for MCO Option, together with MCB 113, in enclosures A2 and A3 130B1413 - Mounting kit for enclosure B3 130B1414 - Mounting kit for MCO Option, together with MCB 113, in enclosure B3 130B7532 - Mounting kit for enclosure A5 130B7533 - Mounting kit for all enclosures B, C, D, E and F (B3 excepted) Danfoss MCO options are not sold without prior advice. Danfoss can offer help with programming / setting up MCO options. Contact Danfoss for advice and prices. Product group: R
- Available
-
- 130B1254
- VLT Adv. Cascade Contr. MCO 102, ctd Upgrades the built-in cascade controller to control up to 8 pumps - More advanced pump control in master / follower mode - The same cascade management hardware applies to the entire power range up to 1.2 MW - Up to 8 pumps in standard cascade control - Up to 8 pumps in master / follower setup Remember to order the Mounting kit if the above MCO option is required retrofitted. 130B7530 - Mounting kit for enclosures A2 and A3 130B1413 - Mounting kit for enclosure B3 130B7532 - Mounting kit for enclosure A5 130B7533 - Mounting kit for all enclosures B, C, D, E and F (B3excepted) Danfoss MCO options are not sold without prior advice. Danfoss can offer help with programming / setting up MCO options. Contact Danfoss for advice and prices. Product group: R
- Available
-
- 130B1258 (AHF-DB-251-400-50-20-A)
- VLT Advanced Harmonic Filter, AHF 005
- Available
-
- 130B1260 (AHF-DB-381-400-50-20-A)
- VLT Advanced Harmonic Filter 005 The Danfoss Advanced Harmonic Filter is a compact passive harmonic filter specially designed to match the Danfoss frequency converters VLT AutomationDrive, VLT AQUA Drive and VLT HVAC/R Drives. The program offers two variants, AHF 005 and AHF 010.Connected in front of the Danfoss VLT frequency converter, the harmonic current distortion on the line is reduced to 5% or 10% at nominal load. Specifications: Line voltage: 380-415V Line frequency: 50Hz Nominal current: 381A THDi less than 5% Cooling concept: Integrated fan with variable speed Efficiency: > 98 % Ambient temperature: 5-45 deg C Enclosure type: X8-V3 IP20 ef Enclosure degree: IP20 (IP21 / NEMA 1 optional) Dimensions: Height: 957mm Width: 468mm Depth: 515mm Accessories: IP21 / NEMA1 Kit for AHF3 X8 : 175U3282 IP21/NEMA1 Kit for AHF3 X8 with capacitor disconnect option:175U6100 Backplate for AHF X7/X8 : 130B3288
- Available
-
- 130B1264
- VLT Extended Relay Card MCB 113, ctd Adds 7 digital inputs and 2 analog outputs for increased flexibility. 4 SPDT relays. Meets NAMUR recommendations. Galvanic isolation capability.
- Available
-
- 130B1266
- VLT MCB 115 Programmable I/O, coated VLT MCB 115 programmable I / O, coated
- Available
-
- 130B1272
- VLT Sensor Input Card MCB 114, coated MCB 114 - PT100 / PT1000 option For FC100-FC200 and FC302, (Painted version). Enables the evaluation of up to 3 PT 100 or 3 PT 1000 sensors - Connection of 2 and 3 wire sensors - Automatic detection of the sensor type - Additional 4-20mA input
- Available
-
- 130B1296
- VLT Modbus TCP MCA 122, coated The first industrial Ethernet-based protocol for automation. Connects to Modbus-TCP-based networks. Able to handle connection interval down to 5 ms in both directions, positioning it among the fastest performing Modbus TCP devices in the market. For master redundancy it features hot swapping between two masters.
- Available
-
- 130B1383
- acc. bag multipck 5 pc frame A2/3 Krones acc. bag multipack 5pcs for A2/3-frame.
- Available
-
- 130B1385
- VLT Profibus DP V1 MCA101 (5pcs)
- Available
-
- 130B1413
- Mounting Kit f. C Option, 40mm, B3 Mounting kit for FC 302, C options, Case size B3 (40mm)
- Available