- Part Number
- Description
- Availability
-
- 130B5601
- VLT DeviceNet converter MCA194 coated VLT DeviceNet converter MCA194 coated
- Available
-
- 130B5646
- VLT EtherCAT MCA 124, coated via MCT 10 MCA 124 Ethercat option painted The VLT EtherCat MCA 124 option enables Connection to EtherCat-based networks via the EtherCat protocol. The option allows an EtherCat connection with full Speed and a connection to the frequency converter with a time interval of 4 ms in both Directions. This enables the MCA124 to be used in Networks from low-power applications to Servo applications. -EoE EtherNet over EtherCat support -HTTP (Hypertext Transfer Protocol) for diagnosis via integrated web server -SMTP (Single Mail Transfer Protocol) for email notification -TCP / IP for easy access to frequency converters Configuration data
- Available
-
- 130B5759
- Control Card Connector Fc-102,202
- Available
-
- 130B5774
- Accessory bag, FCD302
- Available
-
- 130B5776
- LCP 31 Cable, 3m Pre-assembled cable between display and FCD302
- Available
-
- 130B5792
- Handle for FCD302 disc & C/B
- Available
-
- 130B6060-1/2-DT13
- Control board, frecuency converter.
- Available
-
- 130B6064
- Current detection card rated at 37KW-75KW.
- Available
-
- 130B6755
- Fan assembly 70x70x25mm A4 Fan assembly 70x70x25mm A4
- Available
-
- 130B7002
- Driver card for danfoss inverter.
- Available
-
- 130B7367 (MCC102A15KTMU20B)
- VLT dU/dt Filter MCC 102
- Available
-
- 130B7530
- Mounting Kit f. C Option, 40mm, A2/A3 MCF 105 assembly kit A2 / A3 for C option
- Available
-
- 130B7531
- Mounting Kit f. C Option, 60mm, A2/A3 VLT Mounting kit for enclosure sizes A2 and A3. Must be used when retrofitting 1 pc. of the following MCO options, together with MCB 113 Extended relay card (Located in MCO slot): MCO 305 Programmable Motion Controller MCO 350 Synchronizing Controller MCO 351 Positioning controller MCO 360 Salt Controller MCO 361 Lift Controller Product group: R
- Available
-
- 130B7532
- Mounting Kit f. C Option, A5 VLT Mounting kit for enclosure size A5. To be used when retrofitting the following MCO options: MCO 102 Advanced Cascade Control MCO 305 Programmable Motion Controller MCO 350 Synchronizing Controller MCO 351 Positioning controller MCO 360 Salt Controller MCO 361 Lift Controller MCB 113 Extended relay card (Located in MCO slot) Product group: R1
- Available
-
- 130B7533
- Mounting Kit C Option, B/C/D/E/F(not B3) MCF105 C Option, Mounting Kit A2 and A3
- Available
-
- 130B9860
- VLT Safety Option MCB152, coated Safety modules enable machines to interact intelligently with operators to increase safety, reduce system costs, improve flexibility and increase productivity. VLT Safety Option MCB152 provides an intelligent, user-friendly solution to meet the IEC 61800-5-2 functional safety standard and helps to reduce cabling. MCB152 enables activation of the Safe Torque Off (STO) irrespective of where a hazard occurs. The new safety module is certified according to ISO 13849-1 PL d Category 3 and SIL 2 according to EN IEC 61508. The combination of VLT Safety Option MCB152, PROFINET fieldbus option MCA120, and the control card of the VLT AutomationDrive constitutes a PROFIsafe device.
- Available
-
- 131B0001 (FC-302P4K0T5E20H1XXXXXXSXXXXAXBXCXXXXDX)
- VLT AutomationDrive FC-302, (P4K0) 4.0 KW / 5.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 No A Option, No B Option No C1 option, No D option Other options according to Model code
- Available
-
- 131B0002 (FC-302P5K5T5E20H1)
- VLT AutomationDrive FC 300 5.5 KW / 7.5 HP, 380 - 500 VAC, IP20
- Available
-
- 131B0002 (FC-302P5K5T5E20H1XXXXXXSXXXXAXBXCXXXXDX)
- VLT AutomationDrive FC-302, (P5K5) 5.5 KW / 7.5 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A3 No A Option, No B Option No C1 option, No D option Other options according to Model code
- Available
-
- 131B0003 (FC-302P7K5T5E20H1XXXXXXSXXXXAXBXCXXXXDX)
- VLT AutomationDrive FC-302, (P7K5) 7.5 KW / 10 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A3 No A Option, No B Option No C1 option, No D option Other options according to Model code
- Available
-
- 131B0004 (FC-302P7K5T5E20H1BXXXXXSXXXXAXBXCXXXXDX)
- VLT AutomationDrive FC-302, (P7K5) 7.5 KW / 10 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A3 No A Option, No B Option No C1 option, No D option Other options according to Model code
- Available
-
- 131B0005 (FC-302P5K5T5E20H1BXXXXXSXXXXAXBXCXXXXDX)
- VLT AutomationDrive FC-302, (P5K5) 5.5 KW / 7.5 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A3 No A Option, No B Option No C1 option, No D option Other options according to Model code
- Available
-
- 131B0006 (FC-302P4K0T5E20H1BXXXXXSXXXXAXBXCXXXXDX)
- VLT AutomationDrive FC-302, (P4K0) 4.0 KW / 5.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 No A Option, No B Option No C1 option, No D option Other options according to Model code
- Available
-
- 131B0007 (FC-302P2K2T2E20H1XXXXXXSXXXXAXBXCXXXXDX)
- VLT AutomationDrive FC-302, (P2K2) 2.2 KW / 3.0 HP, Three phase, 200 - 240 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) No brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 No A Option, No B Option No C1 option, No D option Other options according to Model code
- Available
-
- 131B0014 (FC-302PK75T5E20H1BXXXXXSXXXXAXBXCXXXXDX)
- VLT AutomationDrive FC-302, (PK75) 0.75 KW / 1.0 HP, Three phase, 380 - 500 VAC, (E20) IP20 / Chassis (H1) RFI Class A1/B (C1) Brake chopper No Local Control Panel Not coated PCB, No Mains Option Latest release standard software. Frame: A2 No A Option, No B Option No C1 option, No D option Other options according to Model code
- Available
Trusted by…