- Part Number
- Description
- Availability
-
- E820S-0015SCEPB-60
- Available
-
- E820S-0030-5-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, safety model, SIL2 / PLd, FREQROL FR-E800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (Single-phase / 1P), Rated active power 400W / 0.4kW (ND Normal duty) / 1/2HP (ND Normal duty), Rated current 3A (ND Normal duty), frequency (output) 0.2-590Hz, with Natural cooling, with RS-485 communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E820S-0030EPA-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, safety model, SIL2 / PLd, FREQROL FR-E800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (Single-phase / 1P), Rated active power 400W / 0.4kW (ND Normal duty) / 1/2HP (ND Normal duty), Rated current 3A (ND Normal duty), frequency (output) 0.2-590Hz, with Natural cooling, with Ethernet + Ethernet/IP + CC-Link + Modbus TCP + BACnet/IP communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E820S-0030EPB-60
- Available
-
- E820S-0030SCEPA-60
- Available
-
- E820S-0030SCEPB-60
- Available
-
- E820S-0050-5-60
- Available
-
- E820S-0050EPA-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, safety model, SIL2 / PLd, FREQROL FR-E800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (Single-phase / 1P), Rated active power 750W / 0.75kW (ND Normal duty) / 1HP (ND Normal duty), Rated current 5A (ND Normal duty), frequency (output) 0.2-590Hz, with Natural cooling, with Ethernet + Ethernet/IP + CC-Link + Modbus TCP + BACnet/IP communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E820S-0050EPB-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, safety model, SIL2 / PLd, FREQROL FR-E800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (Single-phase / 1P), Rated active power 750W / 0.75kW (ND Normal duty) / 1HP (ND Normal duty), Rated current 5A (ND Normal duty), frequency (output) 0.2-590Hz, with Natural cooling, with Ethernet + PROFINET + CC-Link + Modbus TCP communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E820S-0050SCEPA-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, SIL3 / PLe, FREQROL FR-E800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (Single-phase / 1P), Rated active power 750W / 0.75kW (ND Normal duty) / 1HP (ND Normal duty), Rated current 5A (ND Normal duty), frequency (output) 0.2-590Hz, with Natural cooling, with Ethernet + Ethernet/IP + CC-Link + Modbus TCP + BACnet/IP communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E820S-0050SCEPB-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, SIL3 / PLe, FREQROL FR-E800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (Single-phase / 1P), Rated active power 750W / 0.75kW (ND Normal duty) / 1HP (ND Normal duty), Rated current 5A (ND Normal duty), frequency (output) 0.2-590Hz, with Natural cooling, with Ethernet + PROFINET + CC-Link + Modbus TCP communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E820S-0080-5-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, safety model, SIL2 / PLd, FREQROL FR-E800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (Single-phase / 1P), Rated active power 1.5kW (ND Normal duty) / 2HP (ND Normal duty), Rated current 8A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with RS-485 communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E820S-0080EPA-60
- Available
-
- E820S-0080EPB-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, safety model, SIL2 / PLd, FREQROL FR-E800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (Single-phase / 1P), Rated active power 1.5kW (ND Normal duty) / 2HP (ND Normal duty), Rated current 8A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet + PROFINET + CC-Link + Modbus TCP communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E820S-0080SCEPA-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, SIL3 / PLe, FREQROL FR-E800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (Single-phase / 1P), Rated active power 1.5kW (ND Normal duty) / 2HP (ND Normal duty), Rated current 8A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet + Ethernet/IP + CC-Link + Modbus TCP + BACnet/IP communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E820S-0080SCEPB-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, SIL3 / PLe, FREQROL FR-E800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (Single-phase / 1P), Rated active power 1.5kW (ND Normal duty) / 2HP (ND Normal duty), Rated current 8A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet + PROFINET + CC-Link + Modbus TCP communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E820S-0110-5-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, safety model, SIL2 / PLd, FREQROL FR-E800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (Single-phase / 1P), Rated active power 2.2kW (ND Normal duty) / 3HP (ND Normal duty), Rated current 11A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with RS-485 communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E820S-0110EPA-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, safety model, SIL2 / PLd, FREQROL FR-E800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (Single-phase / 1P), Rated active power 2.2kW (ND Normal duty) / 3HP (ND Normal duty), Rated current 11A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet + Ethernet/IP + CC-Link + Modbus TCP + BACnet/IP communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E820S-0110EPB-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, safety model, SIL2 / PLd, FREQROL FR-E800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (Single-phase / 1P), Rated active power 2.2kW (ND Normal duty) / 3HP (ND Normal duty), Rated current 11A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet + PROFINET + CC-Link + Modbus TCP communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E820S-0110SCEPA-60
- Available
-
- E820S-0110SCEPB-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, SIL3 / PLe, FREQROL FR-E800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (Single-phase / 1P), Rated active power 2.2kW (ND Normal duty) / 3HP (ND Normal duty), Rated current 11A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet + PROFINET + CC-Link + Modbus TCP communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E840-0016-5-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, AM terminal, SIL2 / PLd, FREQROL FR-E800 series, input voltage 380Vac-480Vac (400Vac / 415Vac / 440Vac) (3-phase / 3P), Rated active power 400W / 0.4kW (ND Normal duty) / 1/2HP (ND Normal duty), Rated current 1.6A (ND Normal duty), frequency (output) 0.2-590Hz, with Natural cooling, with RS-485 communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E840-0016EPA-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, SIL2 / PLd, FREQROL FR-E800 series, input voltage 380Vac-480Vac (400Vac / 415Vac / 440Vac) (3-phase / 3P), Rated active power 400W / 0.4kW (ND Normal duty) / 1/2HP (ND Normal duty), Rated current 1.6A (ND Normal duty), frequency (output) 0.2-590Hz, with Natural cooling, with Ethernet + Ethernet/IP + CC-Link + Modbus TCP + BACnet/IP communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E840-0016EPB-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, SIL2 / PLd, FREQROL FR-E800 series, input voltage 380Vac-480Vac (400Vac / 415Vac / 440Vac) (3-phase / 3P), Rated active power 400W / 0.4kW (ND Normal duty) / 1/2HP (ND Normal duty), Rated current 1.6A (ND Normal duty), frequency (output) 0.2-590Hz, with Natural cooling, with Ethernet + PROFINET + CC-Link + Modbus TCP communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- E840-0016SCEPA-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, SIL3 / PLe, FREQROL FR-E800 series, input voltage 380Vac-480Vac (400Vac / 415Vac / 440Vac) (3-phase / 3P), Rated active power 400W / 0.4kW (ND Normal duty) / 1/2HP (ND Normal duty), Rated current 1.6A (ND Normal duty), frequency (output) 0.2-590Hz, with Natural cooling, with Ethernet + Ethernet/IP + CC-Link + Modbus TCP + BACnet/IP communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available