- Part Number
- Description
- Availability
-
- FR-A840-00052-E2-60
- Available
-
- FR-A840-00052-E2-60
- (FRA84000052E260) Three phase high performance inverter with integrated ethernet rated at 4A, 1.5kW.
- Available
-
- FR-A840-00052-NPD9
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 1.5kW (ND Normal duty) / 2HP, Rated current 4A (ND Normal duty), frequency (output) 0.2-590Hz, with Heatsnk. cooling, with PROFIBUS communication capability, IP20
- Available
-
- FR-A840-00052-NPDP
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter, pre-programmed, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 1.5kW (ND Normal duty) / 2HP, Rated current 4A (ND Normal duty), frequency (output) 0.2-590Hz, with Heatsnk. cooling, with PROFIBUS communication capability, IP20
- Available
-
- FR-A840-00083-1-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + PTO (Pulse Train Output) FM terminal, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 2.2kW (ND Normal duty) / 3HP (ND Normal duty), Rated current 6A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-A840-00083-1-N6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with extended conformal coating (circuit board + conductors) + PTO (Pulse Train Output) FM terminal, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 2.2kW (ND Normal duty) / 3HP (ND Normal duty), Rated current 6A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP20, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-A840-00083-2-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + analog current output (CA terminal), FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 2.2kW (ND Normal duty) / 3HP (ND Normal duty), Rated current 6A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-A840-00083-E1N6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with Ethernet card + extended conformal coating (circuit board + conductors) + PTO (Pulse Train Output) FM terminal, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 2.2kW (ND Normal duty) / 3HP (ND Normal duty), Rated current 6A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet communication capability, IP20, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-A840-00083-E2-60
- Available
-
- FR-A840-00083-NPD9
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 2.2kW (ND Normal duty) / 3HP (ND Normal duty), Rated current 6A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with PROFIBUS communication capability, IP20
- Available
-
- FR-A840-00083-NPDE
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter, EU / European specification, pre-programmed, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 2.2kW (ND Normal duty) / 3HP (ND Normal duty), Rated current 6A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with PROFIBUS communication capability, IP20
- Available
-
- FR-A840-00083-NPDP
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter, pre-programmed, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 2.2kW (ND Normal duty) / 3HP (ND Normal duty), Rated current 6A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with PROFIBUS communication capability, IP20
- Available
-
- FR-A840-00126-1-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + PTO (Pulse Train Output) FM terminal, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 3.7kW (ND Normal duty) / 5HP (ND Normal duty), Rated current 9A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-A840-00126-1-N6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with extended conformal coating (circuit board + conductors) + PTO (Pulse Train Output) FM terminal, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 3.7kW (ND Normal duty) / 5HP (ND Normal duty), Rated current 9A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP20, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-A840-00126-2-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + analog current output (CA terminal), FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 3.7kW (ND Normal duty) / 5HP (ND Normal duty), Rated current 9A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-A840-00126-E1N6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with Ethernet card + extended conformal coating (circuit board + conductors) + PTO (Pulse Train Output) FM terminal, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 3.7kW (ND Normal duty) / 5HP (ND Normal duty), Rated current 9A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet communication capability, IP20, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-A840-00126-E2-60
- Available
-
- FR-A840-00126-E2-60
- 3 phase inverter, rated at 400V, 3.7KW.
- Available
-
- FR-A840-00126-NPD9
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 3.7kW (ND Normal duty) / 5HP (ND Normal duty), Rated current 9A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with PROFIBUS communication capability, IP20
- Available
-
- FR-A840-00170-1-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + PTO (Pulse Train Output) FM terminal, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 5.5kW (ND Normal duty) / 7.5HP / 7-1/2HP (ND Normal duty), Rated current 12A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-A840-00170-1-N6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with extended conformal coating (circuit board + conductors) + PTO (Pulse Train Output) FM terminal, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 5.5kW (ND Normal duty) / 7.5HP / 7-1/2HP (ND Normal duty), Rated current 12A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP20, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-A840-00170-2-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + analog current output (CA terminal), FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 5.5kW (ND Normal duty) / 7.5HP / 7-1/2HP (ND Normal duty), Rated current 12A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP20, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-A840-00170-E1N6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with Ethernet card + extended conformal coating (circuit board + conductors) + PTO (Pulse Train Output) FM terminal, FREQROL FR-A800 Plus series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 5.5kW (ND Normal duty) / 7.5HP / 7-1/2HP (ND Normal duty), Rated current 12A (ND Normal duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet communication capability, IP20, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-A840-00170-E2-60
- Available
-
- FR-A840-00170-E260
- (FRA84000170E260) 3 phase inverter, rated at 0.17kW.
- Available