-
- Part Number
- Description
- Availability
-
- FR-F820-01250-E3N6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with extended conformal coating (circuit board + conductors), energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 30kW (LD Light duty) / 40HP (LD Light duty), Rated current 114A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-01540-1-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 37kW (LD Light duty) / 50HP (LD Light duty), Rated current 140A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-01540-3-06
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with extended conformal coating (circuit board + conductors) + analog current output (CA terminal), energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 37kW (LD Light duty) / 50HP (LD Light duty), Rated current 140A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-01540-3-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + analog current output (CA terminal), energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 37kW (LD Light duty) / 50HP (LD Light duty), Rated current 140A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-01540-E360
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 37kW (LD Light duty) / 50HP (LD Light duty), Rated current 140A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-01870-1-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 45kW (LD Light duty) / 60HP (LD Light duty), Rated current 170A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-01870-3-06
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with extended conformal coating (circuit board + conductors) + analog current output (CA terminal), energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 45kW (LD Light duty) / 60HP (LD Light duty), Rated current 170A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-01870-3-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + analog current output (CA terminal), energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 45kW (LD Light duty) / 60HP (LD Light duty), Rated current 170A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-01870-E360
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 45kW (LD Light duty) / 60HP (LD Light duty), Rated current 170A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-02330-1-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 55kW (LD Light duty) / 75HP (LD Light duty), Rated current 212A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-02330-3-06
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with extended conformal coating (circuit board + conductors) + analog current output (CA terminal), energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 55kW (LD Light duty) / 75HP (LD Light duty), Rated current 212A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-02330-3-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + analog current output (CA terminal), energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 55kW (LD Light duty) / 75HP (LD Light duty), Rated current 212A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-02330-E360
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 55kW (LD Light duty) / 75HP (LD Light duty), Rated current 212A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-03160-1-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 75kW (LD Light duty) / 100HP (LD Light duty), Rated current 288A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-03160-3-06
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with extended conformal coating (circuit board + conductors) + analog current output (CA terminal), energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 75kW (LD Light duty) / 100HP (LD Light duty), Rated current 288A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-03160-3-60
- FR-F800-240V AC Drive
- Available
-
- FR-F820-03160-E360
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only), energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 75kW (LD Light duty) / 100HP (LD Light duty), Rated current 288A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-03800-1-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 90kW (LD Light duty) / 125HP (LD Light duty), Rated current 346A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-03800-3-60
- FR-F800-240V AC Drive
- Available
-
- FR-F820-03800-3U06
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with extended conformal coating (circuit board + conductors), energy saver, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 90kW (LD Light duty) / 125HP (LD Light duty), Rated current 346A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-03800-E3U6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter, energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 90kW (LD Light duty) / 125HP (LD Light duty), Rated current 346A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-04750-1-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with conformal coating (circuit board only) + PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 110kW (LD Light duty) / 150HP (LD Light duty), Rated current 432A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F820-04750-3-60
- FR-F800-240V AC Drive
- Available
-
- FR-F820-04750-3-U6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with analog current output (CA terminal), energy saver, open type, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 110kW (LD Light duty) / 150HP (LD Light duty), Rated current 432A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00
- Available
-
- FR-F820-04750-3U06
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with extended conformal coating (circuit board + conductors), energy saver, FREQROL FR-F800 series, input voltage 200Vac-240Vac (208Vac / 220Vac / 230Vac) (3-phase / 3P), Rated active power 110kW (LD Light duty) / 150HP (LD Light duty), Rated current 432A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
Trusted by…
Trusted by industry leaders
Trusted by industry leaders