-
- Part Number
- Description
- Availability
-
- FR-F840-315K-1
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 315kW (LD Light duty) / 425HP (LD Light duty), Rated current 610A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00
- Available
-
- FR-F840-45K-1
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 45kW (LD Light duty) / 60HP (LD Light duty), Rated current 85A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00
- Available
-
- FR-F840-45K-2
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with analog current output (CA terminal), energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 45kW (LD Light duty) / 60HP (LD Light duty), Rated current 85A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00
- Available
-
- FR-F840-5.5K-2
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with analog current output (CA terminal), energy saver, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 5.5kW (LD Light duty) / 7.5HP / 7-1/2HP (LD Light duty), Rated current 11.5A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP20
- Available
-
- FR-F840-55K-1
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 55kW (LD Light duty) / 75HP (LD Light duty), Rated current 106A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00
- Available
-
- FR-F840-7.5K-2
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with analog current output (CA terminal), energy saver, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 7.5kW (LD Light duty) / 10HP (LD Light duty), Rated current 16A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP20
- Available
-
- FR-F840-75K-1
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 75kW (LD Light duty) / 100HP (LD Light duty), Rated current 144A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00
- Available
-
- FR-F840-90K-1
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 90kW (LD Light duty) / 125HP (LD Light duty), Rated current 180A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00
- Available
-
- FR-F840-90K-2
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with analog current output (CA terminal), energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 90kW (LD Light duty) / 125HP (LD Light duty), Rated current 180A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00
- Available
-
- FR-F842-07700-1-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with separate converter (FR-CC2; sold separately) + conformal coating (circuit board only) + PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 355kW (LD Light duty) / 475HP (LD Light duty), Rated current 683A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F842-07700-3-U6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with separate converter (FR-CC2; sold separately) + analog current output (CA terminal), energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 355kW (LD Light duty) / 475HP (LD Light duty), Rated current 683A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00
- Available
-
- FR-F842-07700-3U06
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with extended conformal coating (circuit board + conductors), energy saver, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 355kW (LD Light duty) / 475HP (LD Light duty), Rated current 683A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F842-07700-E3U6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with separate converter (FR-CC2; sold separately), energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 355kW (LD Light duty) / 475HP (LD Light duty), Rated current 683A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet communication capability, IP00
- Available
-
- FR-F842-08660-1-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with separate converter (FR-CC2; sold separately) + conformal coating (circuit board only) + PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 400kW (LD Light duty) / 535HP (LD Light duty), Rated current 770A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F842-08660-3-U6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with separate converter (FR-CC2; sold separately) + analog current output (CA terminal), energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 400kW (LD Light duty) / 535HP (LD Light duty), Rated current 770A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00
- Available
-
- FR-F842-08660-3U06
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with extended conformal coating (circuit board + conductors), energy saver, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 400kW (LD Light duty) / 535HP (LD Light duty), Rated current 770A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F842-08660-E3U6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with separate converter (FR-CC2; sold separately), energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 400kW (LD Light duty) / 535HP (LD Light duty), Rated current 770A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet communication capability, IP00
- Available
-
- FR-F842-09620-1-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with separate converter (FR-CC2; sold separately) + conformal coating (circuit board only) + PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 450kW (LD Light duty) / 600HP (LD Light duty), Rated current 866A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F842-09620-3-U6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with separate converter (FR-CC2; sold separately) + analog current output (CA terminal), energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 450kW (LD Light duty) / 600HP (LD Light duty), Rated current 866A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00
- Available
-
- FR-F842-09620-3U06
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with extended conformal coating (circuit board + conductors), energy saver, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 450kW (LD Light duty) / 600HP (LD Light duty), Rated current 866A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F842-09620-E3U6
- Available
-
- FR-F842-10940-1-60
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with separate converter (FR-CC2; sold separately) + conformal coating (circuit board only) + PTO (Pulse Train Output) FM terminal, energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 500kW (LD Light duty) / 675HP (LD Light duty), Rated current 962A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F842-10940-3-U6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with separate converter (FR-CC2; sold separately) + analog current output (CA terminal), energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 500kW (LD Light duty) / 675HP (LD Light duty), Rated current 962A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00
- Available
-
- FR-F842-10940-3U06
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with extended conformal coating (circuit board + conductors), energy saver, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 500kW (LD Light duty) / 675HP (LD Light duty), Rated current 962A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Modbus RTU communication capability, IP00, Chemical resistance (circuit board coating + plated conductors, IEC60721-3-3 3S2 3C2)
- Available
-
- FR-F842-10940-E3U6
- Variable Speed/Frequency Drive (VSD/VFD) / Inverter with separate converter (FR-CC2; sold separately), energy saver, open type, FREQROL FR-F800 series, input voltage 380Vac-500Vac (400Vac / 415Vac / 440Vac / 480Vac) (3-phase / 3P), Rated active power 500kW (LD Light duty) / 675HP (LD Light duty), Rated current 962A (LD Light duty), frequency (output) 0.2-590Hz, with Forced air cooling, with Ethernet communication capability, IP00
- Available