-
- Part Number
- Description
- Availability
-
- NV100-HRU3P30A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-H (high-performance class)), 3-poles (3P), Rated current 30A, Residual current sensitivity 100mA / 300mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Short circuit current rating 18kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-HRU3P30A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-H (high-performance class)), 3-poles (3P), Rated current 30A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Short circuit current rating 18kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-HRU3P40A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-H (high-performance class)), 3-poles (3P), Rated current 40A, Residual current sensitivity 100mA / 300mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Short circuit current rating 18kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-HRU3P40A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-H (high-performance class)), 3-poles (3P), Rated current 40A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Short circuit current rating 18kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-HRU3P50A
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-H (high-performance class)), 3-poles (3P), Rated current 50A, Residual current sensitivity 100mA / 300mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Short circuit current rating 18kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-HRU3P50A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-H (high-performance class)), 3-poles (3P), Rated current 50A, Residual current sensitivity 100mA / 300mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Short circuit current rating 18kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-HRU3P5A
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-H (high-performance class)), 3-poles (3P), Rated current 5A, Residual current sensitivity 100mA / 300mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Short circuit current rating 18kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-HRU3P5A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-H (high-performance class)), 3-poles (3P), Rated current 5A, Residual current sensitivity 100mA / 300mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Short circuit current rating 18kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-HRU3P5A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-H (high-performance class)), 3-poles (3P), Rated current 5A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Short circuit current rating 18kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-HRU3P60A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-H (high-performance class)), 3-poles (3P), Rated current 60A, Residual current sensitivity 100mA / 300mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Short circuit current rating 18kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-HRU3P60A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-H (high-performance class)), 3-poles (3P), Rated current 60A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Short circuit current rating 18kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-HRU3P60A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-H (high-performance class)), 3-poles (3P), Rated current 60A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Short circuit current rating 18kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-HRU3P75A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-H (high-performance class)), 3-poles (3P), Rated current 75A, Residual current sensitivity 100mA / 300mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Short circuit current rating 18kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-KC3P100A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), 3-poles (3P), Rated current 100A, Residual current sensitivity 30mA
- Available
-
- NV100-KC3P75A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), 3-poles (3P), Rated current 75A, Residual current sensitivity 30mA
- Available
-
- NV100-SRU2P10A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-S (standard class)), 2-poles (2P), Rated current 10A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 35kA (230Vac; IEC60947), Short circuit current rating 35kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-SRU2P15A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-S (standard class)), 2-poles (2P), Rated current 15A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 35kA (230Vac; IEC60947), Short circuit current rating 35kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-SRU2P20A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-S (standard class)), 2-poles (2P), Rated current 20A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 35kA (230Vac; IEC60947), Short circuit current rating 35kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-SRU2P25A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-S (standard class)), 2-poles (2P), Rated current 25A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 25kA (230Vac; IEC60947), Short circuit current rating 25kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-SRU2P30A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-S (standard class)), 2-poles (2P), Rated current 30A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 35kA (230Vac; IEC60947), Short circuit current rating 35kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-SRU2P30A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-S (standard class)), 2-poles (2P), Rated current 30A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 35kA (230Vac; IEC60947), Short circuit current rating 35kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-SRU2P40A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-S (standard class)), 2-poles (2P), Rated current 40A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 35kA (230Vac; IEC60947), Short circuit current rating 35kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-SRU2P50A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-S (standard class)), 2-poles (2P), Rated current 50A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 35kA (230Vac; IEC60947), Short circuit current rating 35kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-SRU2P5A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-S (standard class)), 2-poles (2P), Rated current 5A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 35kA (230Vac; IEC60947), Short circuit current rating 35kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV100-SRU2P5A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), NF-S (standard class)), 2-poles (2P), Rated current 5A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 35kA (230Vac; IEC60947), Short circuit current rating 35kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
Trusted by…
Trusted by industry leaders
Trusted by industry leaders