- Part Number
- Description
- Availability
-
- NV250-SVU3P125A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 125A, Residual current sensitivity 100mA / 200mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P125A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 125A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P125A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 125A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P150A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 150A, Residual current sensitivity 100mA / 200mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P150A100S
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 150A, Residual current sensitivity 100mA / 200mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Solderless box terminal connection connection
- Available
-
- NV250-SVU3P150A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 150A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P150A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 150A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P175A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 175A, Residual current sensitivity 100mA / 200mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P175A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 175A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P175A30M
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 175A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P175A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 175A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P200A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 200A, Residual current sensitivity 100mA / 200mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P200A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 200A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P200A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 200A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P225A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 225A, Residual current sensitivity 100mA / 200mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P225A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 225A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P225A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 225A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P250A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 250A, Residual current sensitivity 100mA / 200mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250-SVU3P250A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 250A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 36kA (400Vac; IEC60947), Short circuit current rating 35kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250CV3P125A100-J
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), time-delay type 3-poles (3P), Rated current 125A, Residual current sensitivity 100mA / 200mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250CV3P150A100-J
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), time-delay type 3-poles (3P), Rated current 150A, Residual current sensitivity 100mA / 200mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250CV3P175A100-J
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), time-delay type 3-poles (3P), Rated current 175A, Residual current sensitivity 100mA / 200mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250CV3P200A100-J
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), time-delay type 3-poles (3P), Rated current 200A, Residual current sensitivity 100mA / 200mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250CV3P225A100-J
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), time-delay type 3-poles (3P), Rated current 225A, Residual current sensitivity 100mA / 200mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV250CV3P250A100-J
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), time-delay type 3-poles (3P), Rated current 250A, Residual current sensitivity 100mA / 200mA / 500mA (adjustable), Short circuit breaking capacity (Icu) 25kA (400Vac; IEC60947), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
Trusted by…
Trusted by industry leaders
Trusted by industry leaders