- Part Number
- Description
- Availability
-
- NV50-SVFU2P40A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 2-poles (2P), Rated current 40A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 15kA (230Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU2P50A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 2-poles (2P), Rated current 50A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 15kA (230Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU2P50A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 2-poles (2P), Rated current 50A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 15kA (230Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU2P5A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 2-poles (2P), Rated current 5A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 15kA (230Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU2P5A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 2-poles (2P), Rated current 5A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 15kA (230Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P10A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 10A, Residual current sensitivity 100mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P10A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 10A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P10A30Y
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB) with pre-installed auxiliary switch + vertical lead-wire terminal block, high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 10A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P10A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 10A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P15A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 15A, Residual current sensitivity 100mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P15A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 15A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P15A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 15A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P20A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 20A, Residual current sensitivity 100mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P20A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 20A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P20A30Y
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB) with pre-installed auxiliary switch + vertical lead-wire terminal block, high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 20A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P20A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 20A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P30A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 30A, Residual current sensitivity 100mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P30A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 30A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P30A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 30A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P40A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 40A, Residual current sensitivity 100mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P40A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 40A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P40A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 40A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P50A100
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 50A, Residual current sensitivity 100mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P50A30
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 50A, Residual current sensitivity 30mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NV50-SVFU3P50A50
- Moulded Case Circuit Breaker (MCCB) with embedded earth leakage protection / Earth Leakage Circuit Breaker (ELCB), high-speed type, NF-S (standard class)), 3-poles (3P), Rated current 50A, Residual current sensitivity 50mA, Short circuit breaking capacity (Icu) 10kA (400Vac; IEC60947), Short circuit current rating 14kA (240Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available