- 774600 (PNOZ XM1 24VDC 4n/o 1n/c 2so)
- Safety relay (standalone) Safety relays PNOZplus Inputs: 1-/2-/3-channel wiring with detection of shorts across contacts Outputs: 4 N/O, 1 N/C, 2 semiconductor outputs, 5 test pulse outputs. Automatic/monitored start UB 24 V DC, width: 112.5 mm. Monitoring E-STOP, safety gates Diagnostic interface.
- Available
-
- 774601 (PNOZ X9 42VAC 24VDC 7n/o 2n/c 2so)
- Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 7 N/O, 2 N/C, 2 semiconductor. Automatic/monitored start UB 42 V AC/24 V DC, width: 90mm, integral screw terminals, Monitoring E-STOP, safety gates.
- Available
-
- 774605 (PNOZ X9 100-120VAC 24VDC 7n/o 2n/c 2so)
- Safety relay (standalone), inputs: 1/2-channel wiring with detection of shorts across contacts, outputs: 7 N/O, 2 N/C, 2 SC, automatic/monitored start, UB = 24 V DC, width: 90 mm, screw terminals integrated, monitoring of E-STOP, safety gates. Suitablefor control through SC outputs.
- Available
-
- 774606 (PNOZ X9 200-230VAC 24VDC 7n/o 2n/c 2so)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 7 N/O, 2 N/C,2 SC automatic/manual/monitored start and automatic start with start-up test, UB 200 - 230 V AC/24 V DC, width: 90 mm, screw terminals integrated, monitoring of E-STOP, safety gates.
- Available
-
- 774607 (PNOZ X2.2 24VAC/DC 2n/o)
- Safety relay (standalone), inputs: 1/2-channel wiring with detection of shorts across contacts, outputs: 2 N/O, automatic/monitored start, UB = 24 V AC/DC, width: 22.5 mm, screw terminals integrated, monitoring of E-STOP, safety gates.
- Available
-
- 774609 (PNOZ X9 24VAC 24VDC 7n/o 2 n/c 2so)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 7 N/O, 2 N/C,2 SC automatic/manual/monitored start and automatic start with start-up test, UB 24 V AC/ DC, width: 90 mm, screw terminals integrated, monitoring of E-STOP, safety gates.
- Available
-
- 774610 (PNOZ XV3.1 30/24-240VACDC 3no 1nc 2no t)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d, UB = 24 - 240 V AC/DC, width: 90 mm, screw terminals integrated, E-STOP monitoring, safety gates with 2 delay-on de-energisation contacts, release time 12levels from 0.1 - 30 s.
- Available
-
- 774612 (PNOZ XV3.1 3/24-240VACDC 3no 1nc 2no t)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d, UB = 24 - 240 V AC/DC, width: 90 mm, screw terminals integrated, E-STOP monitoring, safety gates with 2 delay-on de-energisation contacts, release time 12levels from 0.1 - 3 s.
- Low Stock
-
- 774618 (PNOZ XV3.1 300/24-240VACDC 3no 1nc 2no t)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d, UB = 24 - 240 V AC/DC, width: 90 mm, screw terminals integrated, E-STOP monitoring, safety gates with 2 delay-on de-energisation contacts, release time 12levels from 0.3 - 300 s.
- Available
-
- 774620 (PNOZ XE1 24VDC)
- Safety relay/expansion module (standalone) Input: 1-/2-/3-channel wiring with detection of shorts across contacts Width: 22.5 mm. Expansion module for PNOZ XM1. Safety relays PNOZplus.
- Available
-
- 774639 (KOP-XE)
- PNOZplus, PNOZpower, PNOZmulti coupling connector, replacement need.
- Available
-
- 774700 (PNOZ X10 24VAC 6n/o 4n/c 3LED)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 6 N/O, 4 N/C, automatic/monitored start, UB = 24 V AC, width: 90 mm, screw terminals integrated, monitoring of E-STOP, safety gates, light curtain.
- Available
-
- 774701 (PNOZ X10 42VAC 6n/o 4n/c 3LED)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 6 N/O, 4 N/C, automatic/monitored start, UB = 42 V AC, width: 90 mm, plug-in plug-in terminals of screw type, monitoring of E-STOP, safety gates, light guard.
- Available
-
- 774703 (PNOZ X10 110-120VAC 6n/o 4n/c 3LED)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 6 N/O, 4 N/C, automatic/monitored start, UB = 110 - 120 V AC, width: 90 mm, screw terminals integrated, monitoring of E-STOP, safety gates, light curtain.
- Low Stock
-
- 774706 (PNOZ X10 230-240VAC 6n/o 4n/c 3LED)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 6 N/O, 4 N/C, automatic/monitored start, UB = 230 - 240 V AC, width: 90 mm, screw terminals integrated, monitoring of E-STOP, safety gates.
- Available
-
- 774709 (PNOZ X10 24VDC 6n/o 4n/c 3LED)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 6 N/O, 4 N/C automatic/manual/monitored start and automatic start with start-up test, UB 24 V DC, width: 90 mm, screw terminals integrated, monitoring of E-STOP, safety gates.
- Available
-
- 774721 (PNOZ X6 42VAC 3n/o)
- Safety relay (standalone), inputs: 1/2-channel wiring without detection of shorts across contacts, outputs: 3 N/O, automatic/monitored start, UB = 42 V AC, width: 45 mm, plug-in terminals of screw type, monitoring of E-STOP, safety gates.
- Available
-
- 774725 (PNOZ X6 110-120VAC 3n/o)
- Safety relay (standalone), inputs: 1/2-channel wiring without detection of shorts across contacts, outputs: 3 N/O, automatic/monitored start, UB = 110 - 120 V AC, width: 45 mm, screw terminals integrated, monitoring of E-STOP, safety gates.
- Low Stock
-
- 774726 (PNOZ X6 230-240VAC 3n/o)
- Safety relay (standalone), inputs: 1/2-channel wiring without detection of shorts across contacts, outputs: 3 N/O, automatic/monitored start, UB = 230 - 240 V AC, width: 45 mm, screw terminals integrated, monitoring of E-STOP, safety gates.
- Low Stock
-
- 774729 (PNOZ X6 24VAC 24VDC 3n/o)
- Safety relay (standalone), inputs: 1/2-channel wiring without detection of shorts across contacts, outputs: 3 N/O automatic/manual/monitored start, UB 24 V AC/DC, width: 45 mm, screw terminals integrated, monitoring of E-STOP, safety gates.
- Available
-
- 774730 (PNOZ X4 24VDC 3n/o 1n/c)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C, automatic/manual/monitored start, UB 24 V DC, width: 45 mm, screw terminals integrated, monitoring of E-STOP, safety gates.
- Available
-
- 774731 (PNOZ X4 24VAC 3n/o 1n/c)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C, automatic/manual/monitored start, UB = 24 V AC, width: 45 mm, screw terminals integrated, monitoring of E-STOP, safety gates, light curtain.
- Available
-
- 774734 (PNOZ X4 110VAC 3n/o 1n/c)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C, automatic/manual/monitored start, UB = 110 V DC, width: 45 mm, screw terminals integrated, monitoring of E-STOP, safety gates, light curtain.
- Available
-
- 774735 (PNOZ X4 115VAC 3n/o 1n/c)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C, automatic/manual/monitored start, UB = 115 V AC, width: 45 mm, screw terminals integrated, monitoring of E-STOP, safety gates, light curtain.
- Available
-
- 774736 (PNOZ X4 120VAC 3n/o 1n/c)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C, automatic/manual/monitored start, UB = 120 V DC, width: 45 mm, screw terminals integrated, monitoring of E-STOP, safety gates, light curtain.
- Low Stock