- Part Number
- Description
- Availability
-
- 787314 (PNOZ X3.10P C 24VACDC 3n/o 1n/c 1so)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,1 SC, automatic/ monitored start, UB = 24 V AC/DC, width: 45 mm, plug-in screw terminals, monitoring of E-STOP, safety gates Sidewards compatibility with PNOZ X3.
- Available
-
- 787340 (P2HZ X1P C 24VDC 3n/o 1n/c 2so)
- Safety relay (standalone), inputs: Per push button 1 N/O, 1 N/C, outputs: 3 N/O, 1 N/C, 2 SC, UB = 24 V DC, width: 45 mm, plug-in spring-loaded terminals, two-hand control relay/monitoring ofsimultaneity of two-hand push buttons.
- Available
-
- 787341 (P2HZ X1.10P C 24VDC 3n/o 1n/c 2so)
- Safety relay (standalone), inputs: Per push button 1 N/O, 1 N/C, outputs: 3 N/O, 1 N/C, 2 SC, UB = 42 V AC, width: 45 mm, plug-in spring-loaded terminals, two-hand control relay/monitoring ofsimultaneity of two-hand push buttons. Sidewards compatible with P2HZ X1.
- Low Stock
-
- 787354
- Safety Relay, 2 Hand push buttons, 3no, 24vac, W22.5mm, Screw Terminal, 2 Hand Control Relay
- Available
-
- 787355 (P2HZ X4P C 24VDC 3n/o 1n/c)
- Safety relay (standalone), inputs: Per push button 1 N/O, 1 N/C, outputs: 3 N/O, 1 N/C, UB = 24 V DC, width: 22.5 mm, plug-in spring-loaded terminals, two-hand control relay/monitoring ofsimultaneity of two-hand push buttons.
- Available
-
- 787435 (P2HZ X1P C 115VAC 3n/o 1n/c 2so)
- Safety relay (standalone), inputs: Per push button 1 N/O, 1 N/C, outputs: 3 N/O, 1 N/C, 2 SC, UB = 115 V AC, width: 45 mm, plug-in spring-loaded terminals, two-hand control relay/monitoring ofsimultaneity of two-hand push buttons.
- Low Stock
-
- 787500 (PNOZ XV2P C 30/24VDC 2n/o 2n/o t)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 2 N/O, 1 N/Ot-d (t = 0.1 - 30 s), automatic/monitored start, UB = 24 V DC, width: 45 mm, plug-in spring-loaded terminals, monitoring of E-STOP, safety gates.
- Available
-
- 787502 (PNOZ XV2P C 3/24VDC 2n/o 2n/o t)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 2 N/O, 1 N/Ot-d (t = 0.1 - 3 s), automatic/monitored start, UB = 24 V DC, width: 45 mm, plug-in spring-loaded terminals, monitoring of E-STOP, safety gates.
- Available
-
- 787503 (PNOZ XV2P C 1/24VDC 2n/o 2n/o fix)
- Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 2 N/O, 2 N/O (t = 1 s fixed). Automatic/monitored start UB 24 V DC, width: 45 mm, plug-in spring-loaded terminals. Monitoring E-STOP, safety gates.
- Available
-
- 787504 (PNOZ XV2P C 0.5/24VDC 2n/o 2n/o fix)
- Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 2 N/O, 2 N/O (t = 0.5 s fixed). Automatic/monitored start UB 24 V DC, width: 45 mm, plug-in spring-loaded terminals. Monitoring E-STOP, safety gates.
- Available
-
- 787510 (PNOZ XV3P C 30/24 VDC 3n/o 2n/o t)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 2 N/Ot-d (t = 0.1 - 30 s), automatic/monitored start, UB = 24 V DC, width: 45 mm, plug-in spring-loaded terminals, monitoring of E-STOP, safety gates.
- Available
-
- 787511 (PNOZ XV3.3P C 30/24VDC 3n/o 2n/o t)
- Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 3 N/O, 2 N/O (t = 0 - 30 s). Automatic/monitored start UB 24 V DC, width: 45 mm, plug-in spring-loaded terminals. Monitoring E-STOP, safety gates.
- Available
-
- 787512 (PNOZ XV3P C 3/24 VDC 3n/o 2n/o t)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 2 N/Ot-d (t = 0.1 - 3 s), automatic/monitored start, UB = 24 V DC, width: 45 mm, plug-in spring-loaded terminals, monitoring of E-STOP, safety gates.
- Available
-
- 787518 (PNOZ XV3P C 300/24VDC 3n/o 2n/o t)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 2 N/Ot-d (t = 0.3 - 300 s), automatic/monitored start, UB = 24 V DC, width: 45 mm, plug-in spring-loaded terminals, monitoring of E-STOP, safety gates.
- Low Stock
-
- 787520 (PNOZ XV3.1P C 30/24VDC 3n/o 1n/c 2n/o t)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d (t = 0.1 - 30 s), automatic/monitored start, UB = 24 V DC, width: 90 mm, plug-in spring-loaded terminals, monitoring of E-STOP, safety gates.
- Available
-
- 787522 (PNOZ XV3.1P C 3/24VDC 3n/o 1n/c 2n/o t)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d (t = 0.1 - 3 s), automatic/monitored start, UB = 24 V DC, width: 90 mm, plug-in spring-loaded terminals, monitoring of E-STOP, safety gates.
- Low Stock
-
- 787530 (PNOZ XV3.1P C 30/24-240VACDC 3no 1nc 2no)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d (t = 0.1 - 30 s), automatic/monitored start, UB = 24 - 240 V AC/DC, width: 90 mm, plug-in spring-loaded terminals, monitoring of E-STOP, safety gates, light curtain.
- Available
-
- 787532 (PNOZ XV3.1P C 3/24-240VACDC 3no 1nc 2no)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 3 N/O, 1 N/C,2 N/O t-d (t = 0.1 - 3 s), automatic/monitored start, UB = 24 - 240 V AC/DC, width: 90 mm, plug-in spring-loaded terminals, monitoring of E-STOP, safety gates.
- Low Stock
-
- 787538 (PNOZ XV3.1P C300/24-240VACDC 3no 1nc 2no)
- Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 3 N/O, 1 N/C, 2 N/O (t = 0 - 300 s). Automatic/monitored start UB 24 - 240 V AC/DC, width: 90 mm, plug-in spring-loaded terminals. Monitoring E-STOP, safety gates.
- Available
-
- 787540 (PNOZ XV2.1P C 30/24-240VACDC 2n/o 2n/o t)
- Safety relay (standalone) Inputs: 1-/2-channel wiring with/without detection of shorts across contacts Outputs: 2 N/O, 2 N/O (t = 0 - 30 s). Automatic/monitored start UB 24 - 240 V AC/DC, width: 90 mm, plug-in spring-loaded terminals. Monitoring E-STOP, safety gates.
- Available
-
- 787542 (PNOZ XV2.1P C 3/24-240VACDC 2n/o 2n/o t)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 2 N/O, 2 N/Ot-d (t = 0.1 - 3 s), automatic/monitored start, UB = 24 - 240 V AC/DC, width: 90 mm, plug-in spring-loaded terminals, monitoring of E-STOP, safety gates.
- Low Stock
-
- 787548 (PNOZ XV2.1P C 300/24-240VACDC 2n/o 2n/o)
- Safety relay (standalone), inputs: 1/2-channel wiring with/without detection of shorts across contacts, outputs: 2 N/O, 1 N/Ot-d (t = 0.3 - 300 s), automatic/monitored start, UB = 24 - 240 V AC/DC, width: 90 mm, plug-in spring-loaded terminals, monitoring of E-STOP, safety gates.
- Low Stock
-
- 787580 (PZE X4VP C 0,5/24VDC 4n/o fix)
- Contact expansion, inputs: 1-channel wiring, outputs: 4 N/O t-d (t = 3 s), UB = 24 V DC, width 22.5 mm, plug-in spring-loaded terminals, contact block for contact expansion in connection with safety-related control components.
- Available
-
- 787581 (PZE X4VP C 1/24VDC 4n/o fix)
- Contact expansion, inputs: 1-channel wiring, outputs: 4 N/O, (t = 1 s fixed), UB = 24 V DC, width 22.5 mm, plug-in spring-loaded terminals, contact block for contact expansion in connection with safety-related control components.
- Available
-
- 787582 (PZE X4VP C 2/24VDC 4n/o fix)
- Contact expansion, inputs: 1-channel wiring, outputs: 4 N/O, (t = 2 s fixed), UB = 24 V DC, width 22.5 mm, plug-in spring-loaded terminals, contact block for contact expansion in connection with safety-related control components.
- Low Stock