- Part Number
- Description
- Availability
-
- 8177271 (PMCcable FD/D4B8/005/Q25/S1)
- Feedback cable for EnDat 2.2; Cable assembled on both sides Sub-D15 connector <> con.15 round connector 12-pin SpringTec; suitable for all PMC servo controllers (DD5, protego) and the motors PMCtendo SZ.3x; Length 5 m.
- Available
-
- 8177502 (PMCtendo SZ.55/1/2/2/7/K/H/30/00)
- Mo = 16,0Nm; Io = 10,0A; UN = 400V; nN = 3000min-1; Jmot = 13,9 kgcm2; Encoder EQN 1135 EnDat2.2 multiturn; with brake;
- Available
-
- 8177503 (PMCtendo SZ.41/0/1/1/7/K/H/30/00)
- Mo = 3.0 Nm; Io = 2.88 A; UN = 400 V; nN = 3000 min-1; Jmot = 0.93 kgcm2; Encoder ECI 1118 EnDat2.2 single-turn; without brake; Option: with featherkey;
- Available
-
- 8177507 (PMCtendo SZ.44/0/2/2/7/K/H/60/00)
- Mo = 8.40 Nm; Io = 9.78 A; UN = 400 V; nN = 6000 min-1; Jmot = 2.98 kgcm2; Encoder EQN 1135 EnDat2.2 multiturn; without brake.
- Available
-
- 8177508 (PMCtendo SZ.71/1/1/2/7/K/H/30/00)
- Mo = 8.3 Nm Io = 8.0 A UN = 400 V nN = 3000 min-1 Jmot = 10.243 kgcm2 Encoder ECI 1118 EnDat2.2 single-turn; with brake.
- Available
-
- 8177509 (PMCtendo SZ.44/1/2/2/7/K/H/60/00)
- Mo = 8.40 Nm; Io = 9.78 A; UN = 400 V; nN = 6000 min-1; Jmot = 3.546 kgcm2; Encoder EQN 1135 EnDat2.2 multiturn; without brake.
- Available
-
- 8177511 (PMCtendo SZ.42/1/1/2/7/K/H/60/00)
- Mo = 4,9Nm; Io = 7,43A; UN = 400V; nN = 6000min-1; Jmot = 2,196 kgcm2; Encoder ECI 1118 EnDat2.2 singleturn; with brake;
- Available
-
- 8177512 (PMCtendo SZ.41/0/2/2/7/K/H/30/00)
- Mo = 3.0 Nm; Io = 2.88 A; UN = 400 V; nN = 3000 min-1; Jmot = 0.93 kgcm2; Encoder EQN 1135 EnDat2.2 multiturn; without brake;
- Available
-
- 8177514 (PMCtendo SZ.55/1/2/1/7/K/H/30/00)
- Mo = 16,0Nm; Io = 10,0A; UN = 400V; nN = 3000min-1; Jmot = 13,9 kgcm2; Encoder EQN 1135 EnDat2.2 multiturn; with brake; shaft end with feather key.
- Available
-
- 8177515 (PMCtendo SZ.52/0/2/2/7/K/H/30/00)
- Mo = 8.0 Nm; Io = 5.76 A; UN = 400 V; nN = 3000 min-1; Jmot = 5.2 kgcm2; Encoder EQN 1135 EnDat2.2 multiturn; without brake.
- Available
-
- 8177516 (PMCtendo SZ.41/1/2/1/7/K/H/30/00)
- Mo = 3.0 Nm; Io = 2.88 A; UN = 400 V; nN = 3000 min-1; Jmot = 1.122 kgcm2; Encoder EQN 1135 EnDat2.2 multiturn; with brake; Option: with featherkey.
- Available
-
- 8177517 (PMCtendo SZ.33/0/1/1/7/K/H/30/00 )
- Mo = 2.19 Nm; Io = 1.71 A; UN = 400 V; nN = 3000 min-1; Jmot = 0.40 kgcm2; Encoder ECI 1118 EnDat2.2 singleturn; without brake; Option: with featherkey.
- Available
-
- 8177518 (PMCtendo SZ.33/1/1/1/7/K/H/60/00)
- Mo = 2.25 Nm; Io = 3.55 A; UN = 400 V; nN = 6000 min-1; Jmot = 0.586 kgcm2; Encoder ECI 1118 EnDat2.2 singleturn; with brake; Option: with featherkey.
- Available
-
- 8178001 (PMCprotego D.03/20G/0/0/2/208-480VAC)
- Servo amplifier, continuous output current at 3 x 400 VAC: 3 A, Peak output current for 2 s: 9 A, peak output current for 5 s: 6 A, power consumption in S1 mode: 2.2 kVA, integrated brake resistor, hardware options: expansion card PMCprotego S3.SN 8DI 6DO EI BR, expansion card PROFIBUS DP Slave
- Available
-
- 8178002 (PMCprotego D.03/A0G/0/0/2/208-480VAC)
- Technical data at 3 x 400 V AC: Continuous output current: 3 A; Imax (2s) = 9 A; Imax (5 s) = 6 A; Power consumption in S1 mode: 2.2 kVA. Integral brake resistor. Further hardware options: Expansion card PMCprotego S3.SN 8DI 6DO EI BR, Expansion card PROFINET.
- Available
-
- 8178003 (PMCprotego D.06/01G/0/0/2/208-480VAC)
- Servo amplifier, continuous output current at 3 x 400 VAC: 6 A, Peak output current for 2 s: 18 A, peak output current for 5 s: 12 A, power consumption in S1 mode: 4.5 kVA, integrated brake resistor, hardware options: expansion card PMCprotego S3.SN 8DI 6DO EI BR, expansion card PosI/O.
- Available
-
- 827100 (ZUZ 24VDC 24/110/230VAC 2c/o)
- Voltage monitoring relay, to monitor 1-phase supplies is used as a threshold value element, monitoring device and controlelement, measuring voltage is used as supply voltage, 2 auxiliary contacts (C/O), width = 22.5 mm, UB = 24 V DC, 24 V AC, 110 V AC, 230 V AC.
- Available
-
- 827110 (ZUZ-S 42/48/120/240VAC 2c/o)
- Voltage monitoring relay, to monitor 1-phase supplies is used as a threshold value element, monitoring device and controlelement, measuring voltage is used as supply voltage, 2 auxiliary contacts (C/O), width = 22.5 mm, UB = 24 V AC, 24 V AC, 12 V AC, 240 V AC.
- Low Stock
-
- 827220 (S1UM 24VAC/DC UM 0.1-500VAC/DC)
- Voltage monitoring relay, to monitor min. and max. voltage values, 12 measuring ranges 0.1 - 500 V AC/DC selectable, 0.40 -400 Hz, width = 22.5 mm, UB = 24 V DC.
- Available
-
- 827225 (S1UM 24VDC UM 0.1-500VAC/DC UP)
- Voltage monitoring relay, to monitor min. and max. voltage values, 12 measuring ranges 0.1 - 500 V AC/DC selectable, 0.40 -400 Hz, width = 22.5 mm, UB = 24 V DC, measuring inputs are notpolarity-sensitive.
- Available
-
- 827230 (S1UM 24VAC UM 0.1-500VAC/DC)
- Voltage monitoring relay, to monitor min. and max. voltage values, 12 measuring ranges 0.1 - 500 V AC/DC selectable, 0.40 -400 Hz, width = 22.5 mm, UB = 24 V AC.
- Available
-
- 827235 (S1UM 24VAC UM 0.1-500VAC/DC UP)
- Voltage monitoring relay, to monitor min. and max. voltage values, 12 measuring ranges 0.1 - 500 V AC/DC selectable, 0.40 -400 Hz, width = 22.5 mm, UB = 24 V AC, measuring inputs are notpolarity-sensitive.
- Available
-
- 827240 (S1UM 42-48VAC UM 0.1-500VAC/DC)
- Voltage monitoring relay, to monitor min. and max. voltage values, 12 measuring ranges 0.1 - 500 V AC/DC selectable, 0.40 -400 Hz, width = 22.5 mm, UB = 42 - 48 V AC.
- Low Stock
-
- 827245 (S1UM 42-48VAC UM 0.1-500VAC/DC UP)
- Voltage monitoring relay, to monitor min. and max. voltage values, 12 measuring ranges 0.1 - 500 V AC/DC selectable, 0.40 -400 Hz, width = 22.5 mm, UB = 42 - 48 V AC, measuring inputs are not polarity-sensitive.
- Low Stock
-
- 827250 (S1UM 110-130VAC UM 0.1-500VAC/DC)
- Voltage monitoring relay, to monitor min. and max. voltage values, 12 measuring ranges 0.1 - 500 V AC/DC selectable, 0.40 -400 Hz, width = 22.5 mm, UB = 110 - 130 V AC.
- Available
Trusted by…