Part Number
Description
Availability
-
- 3NP5060-0EA26-ZA02
- Fuse switch disconnector I=160A, U=690V, 3-pole AS 1 NO + 1 NC for cable lug connection with safety monitoring by 3RV, with AS 2 NO fuse size NH00 with 3-meter connecting cable
- Available
-
- 3NP5060-0EA86-ZA01
- Fuse switch disconnector I=160A, U=690V, 3-pole AS 1 NO + 1 NC for cable lug connection with safety monitoring by 3RV, with AS 1 NO + 1 NC fuse size NH00 tin-coated contacts
- Available
-
- 3NP5060-0EA86-ZA02
- Fuse switch disconnector I=160A, U=690V, 3-pole AS 1 NO + 1 NC for cable lug connection with safety monitoring by 3RV, with AS 1 NO + 1 NC fuse size NH00 with 3-meter connecting cable
- Available
-
- 3NP5060-0EA86-ZX95
- Fuse switch disconnector I=160A, U=690V, 3-pole AS 1 NO + 1 NC for cable lug connection with safety monitoring by 3RV, with AS 1 NO + 1 NC fuse size NH00 reusable packaging packaging quantity = 7 units
- Available
-
- 3NP5060-0EB86-ZA01
- Fuse switch disconnector I=160A, U=690V, 3-pole AS 1 NO + 1 NC with terminal clamp connection with safety monitoring by 3VU13, with AS 1 NO + 1 NC fuse size NH00 tin-coated contacts
- Available
-
- 3NP5060-0EB86-ZA02
- Fuse switch disconnector I=160A, U=690V, 3-pole AS 1 NO + 1 NC with terminal clamp connection with safety monitoring by 3VU13, with AS 1 NO + 1 NC fuse size NH00 with 3-meter connecting cable
- Available
-
- 3NP5260-0EA86-ZA01
- Fuse switch disconnector I = 250 A, U = 690 V AS 1 NO + 1 NC for cable lug connection fuse size NH0 and NH1 with safety monitoring by 3RV, 1 NO + 1 NC tin-coated contacts
- Available
-
- 3NP5260-0EA86-ZA02
- Fuse switch disconnector I = 250 A, U = 690 V AS 1 NO + 1 NC for cable lug connection fuse size NH0 and NH1 with safety monitoring by 3RV, 1 NO + 1 NC with 3-meter connecting cable
- Available
-
- 3NP5360-0EA86-ZA01
- Fuse switch disconnector I = 400 A, U = 690 V AS 1 NO + 1 NC for cable lug connection fuse size NH1 and NH2 with safety monitoring by 3RV, with 1 NO + 1 NC tin-coated contacts
- Available
-
- 3NP5360-0EA86-ZA02
- Fuse switch disconnector I = 400 A, U = 690 V AS 1 NO + 1 NC for cable lug connection fuse size NH1 and NH2 with safety monitoring by 3RV, with 1 NO + 1 NC with 3-meter connecting cable
- Available
-
- 3NP5460-0EA86-ZA01
- Fuse switch disconnector I = 630 A, U = 690 V AS 1 NO + 1 NC for cable lug connection fuse size NH2 and NH3 with safety monitoring by 3RV, with 1 NO + 1 NC tin-coated contacts
- Available
-
- 3NP5460-0EA86-ZA02
- Fuse switch disconnector I = 630 A, U = 690 V AS 1 NO + 1 NC for cable lug connection fuse size NH2 and NH3 with safety monitoring by 3RV, with 1 NO + 1 NC with 3-meter connecting cable
- Available
-
- 3RA29161A
- Safety main power connector for series connection of 2 contactors 3RT201, Size S00 screw terminal
- Available
-
- 3RA29261A
- Safety main power connector for series connection of two contactors 3RT202. Size S0 screw terminal
- Available
-
- 3RA2936-1A
- Safety main power connector for series connection of two contactors 3RT203. Size S2 screw terminal
- Available
-
- 3RK1105-1AE04-1CA0
- ASIsafe Basis Safety monitor 1 F-RO 1 enabling circuit IP20, with screw terminal removable terminals Safe output relay Response time max. 50 ms Monitor type 1, Version 3 Can be used up to Category 4 (EN954-1) up to PL E (EN ISO 13849-1) up to SIL 3 (IEC 61508)
- Available
-
- 3RK1105-1AE04-2CA0
- ASIsafe extended Safety monitor 1 F-RO 1 enabling circuit IP20, with screw terminal removable terminals Safe output relay Response time maximum 40 ms Monitor type 3, Version 3 Can be used up to Category 4 (EN954-1) up to PL E (EN ISO 13849-1) up to SIL 3 (IEC 61508)
- Available
-
- 3RK1105-1AE04-3CA0
- ASIsafe extended Safety monitor 1 F-RO 1 enabling circuit IP20, with screw terminal removable terminals Safe output relay Response time max. 50 ms Monitor type 3, Version 3 Can be used up to Category 4 (EN954-1) up to PL E (EN ISO 13849-1) up to SIL 3 (IEC 61508)
- Available
-
- 3RK1105-1AG04-0CA0
- ASIsafe Basis Safety monitor 1 F-RO 1 enabling circuit IP20, with spring-type terminal removable terminals Safe output relay Response time maximum 40 ms Monitor type 1, Version 3 Can be used up to Category 4 (EN954-1) up to PL E (EN ISO 13849-1) up to SIL 3 (IEC 61508)
- Available
-
- 3RK1105-1AG04-2CA0
- ASIsafe extended Safety monitor 1 F-RO 1 enabling circuit IP20, with spring-type terminal removable terminals Safe output relay Response time maximum 40 ms Monitor type 3, Version 3 Can be used up to Category 4 (EN954-1) up to PL E (EN ISO 13849-1) up to SIL 3 (IEC 61508)
- Available
-
- 3RK1105-1BE04-1CA0
- ASIsafe Basis Safety monitor 2 F-RO 2 enabling circuits IP20, with screw terminal removable terminals Safe output relay Response time max. 50 ms Monitor type 2, Version 3 Can be used up to Category 4 (EN954-1) up to PL E (EN ISO 13849-1) up to SIL 3 (IEC 61508)
- Available
-
- 3RK1105-1BE04-3CA0
- ASIsafe extended Safety monitor 2 F-RO 2 enabling circuits IP20, with screw terminal removable terminals Safe output relay Response time max. 50 ms Monitor type 4, Version 3 Can be used up to Category 4 (EN954-1) up to PL E (EN ISO 13849-1) up to SIL 3 (IEC 61508)
- Available
-
- 3RK1105-1BE04-4CA0
- ASIsafe extended Safety monitor 2 F-RO with integrated safe slave 2 enabling circuits included Control of a safe AS-i output Safe coupling IP20, with screw terminal removable terminals Safe output relay Response time max. 40 ms Monitor type 6, Version 3 Can be used up to Category 4 (EN954-1) up to PL E (EN ISO 13849-1) up to SIL 3 (IEC 61508)
- Available
-
- 3RK1105-1BG04-0CA0
- ASIsafe Basis Safety monitor 2 F-RO 2 enabling circuits IP20, with spring-type terminal removable terminals Safe output relay Response time maximum 40 ms Monitor type 2, Version 3 Can be used up to Category 4 (EN954-1) up to PL E (EN ISO 13849-1) up to SIL 3 (IEC 61508)
- Available
-
- 3RK1105-1BG04-2CA0
- ASIsafe extended Safety monitor 2 F-RO 2 enabling circuits IP20, with spring-type terminal removable terminals Safe output relay Response time maximum 40 ms Monitor type 4, Version 3 Can be used up to Category 4 (EN954-1) up to PL E (EN ISO 13849-1) up to SIL 3 (IEC 61508)
- Available