- 1FN3450-3WB00-0BA1
- SIMOTICS L primary section; component 3-phase synchronous motor; peak load version; cover prepared for 2 metric screw connections; connection of power and signal separated; FN=2895 N; Fmax=7760 N; Vmax FN=164 m/min; Vmax Fmax=62 m/min; In=17.9 A; Imax=52.7 A when using direct motors, please observe the national and international license conditions so that no infringements of property rights occur
- Available
-
- 1FN3450-3WB00-0BA3
- SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; FN=2895N; Fmax=7760N; Vmax FN=164m/min; Vmax Fmax=62 m/min; In=17.9 A; Imax=52.7A with PTC120 and Temperature sensor Pt1000
- Available
-
- 1FN3450-3WB50-0AA1
- SIMOTICS L primary section; component 3-phase synchronous motor; peak load version; connection of power and signal in one line; cover prepared for a screw connection; FN=2895 N; Fmax=7760 N; Vmax FN=217 m/min; Vmax Fmax=90 m/min; In=22.8 A; Imax=67.3 A when using direct motors, please observe the national and international license conditions so that no infringements of property rights occur
- Available
-
- 1FN3450-3WB50-0AA3
- SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Connection of power and signal in one cable; Cover prepared for a cable gland; FN=2895N; Fmax=7760N; Vmax FN=217 m/min; Vmax Fmax=90 m/min; In=22.8 A; Imax=67.3A with PTC120 and Temperature sensor Pt1000
- Available
-
- 1FN3450-3WB50-0BA1
- SIMOTICS L primary section; component 3-phase synchronous motor; peak load version; cover prepared for 2 metric screw connections; connection of power and signal separated; FN=2895 N; Fmax=7760 N; Vmax FN=217 m/min; Vmax Fmax=90 m/min; In=22.8 A; Imax=67.3 A when using direct motors, please observe the national and international license conditions so that no infringements of property rights occur
- Available
-
- 1FN3450-3WB50-0BA3
- SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; FN=2895N; Fmax=7760N; Vmax FN=217 m/min; Vmax Fmax=90 m/min; In=22.8 A; Imax=67.3A with PTC120 and Temperature sensor Pt1000
- Available
-
- 1FN3450-3WB50-0KA1
- SIMOTICS L primary section. component 3-phase synchronous motor. peak load version. FN=2895 N. Fmax=7760 N. Vmax FN=217 m/min. Vmax Fmax=90 m/min. In=22.8 A. Imax=67.3 A connection of power and signal combined. with combi connector. receptacle 1 x.
- Available
-
- 1FN3450-3WC00-0AA1
- SIMOTICS L primary section; component 3-phase synchronous motor; peak load version; connection of power and signal in one line; cover prepared for a screw connection; FN=2895 N; Fmax=7760 N; Vmax FN=275 m/min; Vmax Fmax=120 m/min; In=28.1 A; Imax=83 A when using direct motors, please observe the national and international license conditions so that no infringements of property rights occur
- Available
-
- 1FN3450-3WC00-0AA3
- SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Connection of power and signal in one cable; Cover prepared for a cable gland; FN=2895N; Fmax=7760N; Vmax FN=275m/min; Vmax Fmax=120m/min; In=28.1A; Imax=83A with PTC120 and Temperature sensor Pt1000
- Available
-
- 1FN3450-3WC00-0BA1
- SIMOTICS L primary section; component 3-phase synchronous motor; peak load version; cover prepared for 2 metric screw connections; connection of power and signal separated; FN=2895 N; Fmax=7760 N; Vmax FN=275 m/min; Vmax Fmax=120 m/min; In=28.1 A; Imax=83 A when using direct motors, please observe the national and international license conditions so that no infringements of property rights occur
- Available
-
- 1FN3450-3WC00-0BA3
- SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; FN=2895N; Fmax=7760N; Vmax FN=275m/min; Vmax Fmax=120m/min; In=28.1A; Imax=83A with PTC120 and Temperature sensor Pt1000
- Available
-
- 1FN3450-3WE00-0AA1
- SIMOTICS L primary section; component 3-phase synchronous motor; peak load version; connection of power and signal in one line; cover prepared for a screw connection; FN=2895 N; Fmax=7760 N; Vmax FN=519 m/min; Vmax Fmax=240 m/min; In=50.7 A; Imax=149.6 A when using direct motors, please observe the national and international license conditions so that no infringements of property rights occur
- Available
-
- 1FN3450-3WE00-0AA3
- SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Connection of power and signal in one cable; Cover prepared for a cable gland; FN=2895N; Fmax=7760N; Vmax FN=519m/min; Vmax Fmax=240 m/min; In=50.7A; Imax=149.6A with PTC120 and Temperature sensor Pt1000
- Available
-
- 1FN3450-3WE00-0BA1
- SIMOTICS L primary section; component 3-phase synchronous motor; peak load version; cover prepared for 2 metric screw connections; connection of power and signal separated; FN=2895 N; Fmax=7760 N; Vmax FN=519 m/min; Vmax Fmax=240 m/min; In=50.7 A; Imax=149.6 A when using direct motors, please observe the national and international license conditions so that no infringements of property rights occur
- Available
-
- 1FN3450-3WE00-0BA3
- SIMOTICS L primary section; Component 3-phase synchronous motor; Peak load version; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; FN=2895N; Fmax=7760N; Vmax FN=519m/min; Vmax Fmax=240 m/min; In=50.7A; Imax=149.6A with PTC120 and Temperature sensor Pt1000
- Available
-
- 1FN3450-4NB80-0BA1
- SIMOTICS L primary section; component 3-phase synchronous motor; continuous load model; cover prepared for 2 metric threaded joints; connection of power and signal separated; with FN=5185N; Fmax=8810 N; Vmax FN=190 m/min; Vmax Fmax=106 m/min; In=40.8 A; Imax=85.8 A when using direct motors, please observe the national and international license conditions so that no infringements of property rights occur
- Available
-
- 1FN3450-4NB80-0BA3
- SIMOTICS L primary section; Component 3-phase synchronous motor; Continuous load model; Cover prepared for 2 metric threaded joints; Connection of power and signal separated; with FN=5185N; Fmax=8810N; Vmax FN=190m/min; Vmax Fmax=106 m/min; In=40.8A; Imax=85.8A with PTC120 and Temperature sensor Pt1000
- Available
-
- 1FN3450-4PK00-0AA0
- SIMOTICS L precision cooler for primary section 1FN3450-4W... Component 3-phase synchronous motor
- Available
-
- 1FN3450-4PK10-0AA0
- SIMOTICS L precision cooler for primary section 1FN3450-4N... Component 3-phase synchronous motor
- Available
-
- 1FN3450-4SA00-0AA0
- SIMOTICS L Secondary section for linear motor 1FN3... Size 450; Component 3-phase synchronous motor; length 184mm
- Available
-
- 1FN3450-4TP00-1AC5
- SIMOTICS L Secondary section cover S for size 450; component 3-phase synchronous motor; cover for 2.5 Secondary section segments
- Available
-
- 1FN3450-4TP00-1AD0
- SIMOTICS L Secondary section cover for size 450; component 3-phase synchronous motor; cover for 3 Secondary section segments
- Available
-
- 1FN3450-4TP00-1AD5
- SIMOTICS L Secondary section cover for size 450; component 3-phase synchronous motor; cover for 3.5 Secondary section segments
- Available
-
- 1FN3450-4TP00-1AE0
- SIMOTICS L Secondary section cover for size 450; component 3-phase synchronous motor; cover for 4 Secondary section segments
- Available
-
- 1FN3450-4TP00-1AF0
- SIMOTICS L Secondary section cover for size 450; component 3-phase synchronous motor; cover for 5 Secondary section segments
- Available