-
- Part Number
- Description
- Availability
-
- 3TK2835-1BB40
- Safety Combination, Siguard Press Contro
- Low Stock
-
- 3TK2835-2AB20
- Safety Combination, Siguard Press Contro
- Low Stock
-
- 3TK2835-2AJ20
- Safety Combination, Siguard
- Available
-
- 3TK2835-2AL20
- Safety Combination, Siguard
- Available
-
- 3TK2840-1BB40
- SIRIUS safety relay with electronic enabling circuits (EC) 24 V DC, 22.5 mm Screw terminal EC instantaneous: 2 HL EC delayed: 0 SC: 0 Autostart/monitored start Base unit Maximum achieved SIL: 2, PL: d
- Available
-
- 3TK2840-1BB40-0FB0
- SIRIUS Safety Relay
- Available
-
- 3TK2840-2BB40
- SIRIUS safety relay with electronic enabling circuits (EC) 24 V DC, 22.5 mm Spring-type terminal EC instantaneous: 2 HL EC delayed: 0 SC: 0 Autostart/monitored start Base unit Maximum achieved SIL: 2, PL: d
- Available
-
- 3TK2841-1BB40
- SIRIUS safety relay with electronic enabling circuits (EC) 24 V DC, 22.5 mm Screw terminal EC instantaneous: 2 HL EC delayed: 0 SC: 0 Autostart/monitored start Standard device Maximum achieved SIL: 3, PL: e
- Available
-
- 3TK2841-1BB40-0FB0
- Siguard Safety Combination
- Available
-
- 3TK2841-2BB40
- SIRIUS safety relay with electronic enabling circuits (EC) 24 V DC, 22.5 mm Spring-type terminal EC instantaneous: 2 HL EC delayed: 0 SC: 0 Autostart/monitored start Standard device Maximum achieved SIL: 3, PL: e
- Available
-
- 3TK2842-1BB41
- SIRIUS safety relay with electronic enabling circuits (EC) 24 V DC, 22.5 mm Screw terminal EC instantaneous: 1 HL EC delayed: 1 HL, 0.05...3 s MK: 0 Autostart/monitored start Standard device Maximum achieved SIL: 3, PL: e
- Available
-
- 3TK2842-1BB41-0FB0
- SIRIUS Safety Relay
- Available
-
- 3TK2842-1BB42
- SIRIUS safety relay with electronic enabling circuits (EC) 24 V DC, 22.5 mm Screw terminal EC instantaneous: 1 HL EC delayed: 1 HL, 0.5...30 s SC: 0 Autostart/monitored start Standard device Maximum achieved SIL: 3, PL: e
- Available
-
- 3TK2842-1BB42-0FB0
- SIRIUS Safety Relay
- Available
-
- 3TK2842-1BB44
- SIRIUS safety relay with electronic enabling circuits (EC) 24 V DC, 22.5 mm Screw terminal EC instantaneous: 1 HL EC delayed: 1 HL, 5...300 s SC: 0 Autostart/monitored start Standard device Maximum achieved SIL: 3, PL: e
- Available
-
- 3TK2842-2BB41
- SIRIUS safety relay with electronic enabling circuits (EC) 24 V DC, 22.5 mm Spring-type terminal EC instantaneous: 1 HL EC delayed: 1 HL, 0.05...3 s MK: 0 Autostart/monitored start Standard device Maximum achieved SIL: 3, PL: e
- Available
-
- 3TK2842-2BB42
- SIRIUS safety relay with electronic enabling circuits (EC) 24 V DC, 22.5 mm Spring-type terminal EC instantaneous: 1 HL EC delayed: 1 HL, 0.5...30 s SC: 0 Autostart/monitored start Standard device Maximum achieved SIL: 3, PL: e
- Available
-
- 3TK2842-2BB44
- SIRIUS safety relay with electronic enabling circuits (EC) 24 V DC, 22.5 mm Spring-type terminal EC instantaneous: 1 HL EC delayed: 1 HL, 5...300 s SC: 0 Autostart/monitored start Standard device Maximum achieved SIL: 3, PL: e
- Available
-
- 3TK2845-1BB40
- SIRIUS Safety Relay With Electronic Rele
- Available
-
- 3TK2845-1BB41
- SIRIUS Safety Relay With Electrical Release
- Available
-
- 3TK2845-1BB42
- SIRIUS Safety Relay With Electrical Release
- Available
-
- 3TK2845-1BB44
- SIRIUS Safety Relay
- Available
-
- 3TK2845-1DB40
- SIRIUS safety relay with relay and electronic 24 V DC, 45 mm screw terminal EC instantaneous: 4 NO EC delayed: 0 SC: 1 monitored start Basic device Maximum achievable PL according to EN 13849-1: Maximum achievable SIL according to IEC 61508: 3
- Available
-
- 3TK2845-1DB41
- SIRIUS safety relay with relay and electronic 24 V DC, 45 mm Screw terminal EC instantaneous: 2 NO EC delayed: 2 SC: 1 Monitored start Basic device Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3
- Available
-
- 3TK2845-1DB42
- SIRIUS safety relay with relay and electronic 24 V DC, 45 mm Screw terminal EC instantaneous: 2 NO EC delayed: 2 SC: 1 Monitored start Basic device Maximum achievable PL according to EN 13849-1: e Maximum achievable SIL according to IEC 61508: 3
- Available
Trusted by…
Trusted by industry leaders
Trusted by industry leaders