-
- Part Number
- Description
- Availability
-
- 3VL2716-1DC33-8TB1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Line Protection Electronic Trip Unit Tm, Li In=160a, Rated Current Ir=125...160a, Overload Protection, Ii=800...1600a, Short-circuit Protection Shunt Release 208...277 V A
- Available
-
- 3VL2716-1DC33-8TD1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Line Protection Electronic Trip Unit Tm, Li In=160a, Rated Current Ir=125...160a, Overload Protection, Ii=800...1600a, Short-circuit Protection Shunt Release 208...277 V A
- Available
-
- 3VL2716-1DC36-0AA0
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Line Protection Electronic Trip Unit Tm, Li In=160a, Rated Current Ir=125...160a, Overload Protection, Ii=800...1600a, Short-circuit Protection With Screw Terminals Withou
- Available
-
- 3VL2716-1DC36-0AB1
- Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=160A, rated current IR=125...160A, overload protection, II=800...1600A, short-circuit protection with screw terminals without auxiliary release Auxiliary switch mounting kit 2 AUXILIARY (1 NO + 1 NC)
- Available
-
- 3VL2716-1DC36-0AD1
- Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=160A, rated current IR=125...160A, overload protection, II=800...1600A, short-circuit protection with screw terminals without auxiliary release Auxiliary/alarm switch mounting kit 2 AUXILIARY (1 NO+1 NC) +1 AS (1 NO)
- Available
-
- 3VL2716-1DC36-2HD1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Line Protection Electronic Trip Unit Tm, Li In=160a, Rated Current Ir=125...160a, Overload Protection, Ii=800...1600a, Short-circuit Protection With Screw Terminals Underv
- Available
-
- 3VL2716-1DC36-2JD1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Line Protection Electronic Trip Unit Tm, Li In=160a, Rated Current Ir=125...160a, Overload Protection, Ii=800...1600a, Short-circuit Protection With Screw Terminals Underv
- Available
-
- 3VL2716-1DC36-8CD1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Line Protection Electronic Trip Unit Tm, Li In=160a, Rated Current Ir=125...160a, Overload Protection, Ii=800...1600a, Short-circuit Protection With Screw Terminals Shunt
- Available
-
- 3VL2716-1DE33-0AA0
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Non-auto. Air Circuit Breaker Electronic Trip Unit Magnetic In=160a, Rated Current Ii=2500a, Short-circuit Protection Without Auxiliary Release Without Auxiliary/alarm Switch
- Available
-
- 3VL2716-1DE33-0AB1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Non-auto. Air Circuit Breaker Electronic Trip Unit Magnetic In=160a, Rated Current Ii=2500a, Short-circuit Protection Without Auxiliary Release Auxiliary Switch Mounting Kit 2 A
- Available
-
- 3VL2716-1DE33-0AD1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Non-auto. Air Circuit Breaker Electronic Trip Unit Magnetic In=160a, Rated Current Ii=2500a, Short-circuit Protection Without Auxiliary Release Auxiliary/alarm Switch Mounting K
- Available
-
- 3VL2716-1DE33-8TA0
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Non-auto. Air Circuit Breaker Electronic Trip Unit Magnetic In=160a, Rated Current Ii=2500a, Short-circuit Protection Shunt Release 208...277 V Ac Without Auxiliary/alarm Switch
- Available
-
- 3VL2716-1DE33-8TB1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Non-auto. Air Circuit Breaker Electronic Trip Unit Magnetic In=160a, Rated Current Ii=2500a, Short-circuit Protection Shunt Release 208...277 V Ac Auxiliary Switch Mounting Kit
- Available
-
- 3VL2716-1DE33-8TD1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Non-auto. Air Circuit Breaker Electronic Trip Unit Magnetic In=160a, Rated Current Ii=2500a, Short-circuit Protection Shunt Release 208...277 V Ac Auxiliary/alarm Switch Mountin
- Available
-
- 3VL2716-1DE36-0AA0
- Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, non-auto. air circuit breaker Trip Unit magnetic In=160A, rated current II=2500A, short-circuit protection with screw terminals without auxiliary release without auxiliary/alarm switch
- Available
-
- 3VL2716-1DE36-0AB1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Non-auto. Air Circuit Breaker Electronic Trip Unit Magnetic In=160a, Rated Current Ii=2500a, Short-circuit Protection With Screw Terminals Without Auxiliary Release Auxiliary Sw
- Available
-
- 3VL2716-1DE36-0AD1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Non-auto. Air Circuit Breaker Electronic Trip Unit Magnetic In=160a, Rated Current Ii=2500a, Short-circuit Protection With Screw Terminals Without Auxiliary Release Auxiliary/al
- Available
-
- 3VL2716-1DK33-0AA0
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Starter Combination Electronic Trip Unit Magnetic In=160a, Rated Current Ii=1250...2500a, Short-circuit Protection Without Auxiliary Release Without Auxiliary/alarm Switch
- Available
-
- 3VL2716-1DK33-0AB1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Starter Combination Electronic Trip Unit Magnetic In=160a, Rated Current Ii=1250...2500a, Short-circuit Protection Without Auxiliary Release Auxiliary Switch Mounting Kit
- Available
-
- 3VL2716-1DK33-0AD1
- Circuit breaker VL160N standard breaking capacity Icu=55kA, 415V AC 3-pole, starter combination Trip Unit magnetic In=160A, rated current II=1250...2500A, short-circuit protection without auxiliary release Auxiliary/alarm switch mounting kit 2 AUXILIARY (1 NO+1 NC) +1 AS (1 NO)
- Available
-
- 3VL2716-1DK36-0AA0
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Starter Combination Electronic Trip Unit Magnetic In=160a, Rated Current Ii=1250...2500a, Short-circuit Protection With Screw Terminals Without Auxiliary Release Without A
- Available
-
- 3VL2716-1EC43-0AA0
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 4-pole, Line Protection Electronic Trip Unit Tm, Li In=160a, Rated Current Ir=125...160a, Overload Protection, Ii=800...1600a, Short-circuit Protection N Protected Without Auxilia
- Available
-
- 3VL2716-1EC43-0AB1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 4-pole, Line Protection Electronic Trip Unit Tm, Li In=160a, Rated Current Ir=125...160a, Overload Protection, Ii=800...1600a, Short-circuit Protection N Protected Without Auxilia
- Available
-
- 3VL2716-1EC43-2HD1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 4-pole, Line Protection Electronic Trip Unit Tm, Li In=160a, Rated Current Ir=125...160a, Overload Protection, Ii=800...1600a, Short-circuit Protection N Protected Undervoltage Re
- Available
-
- 3VL2716-1EC43-2PD1
- Circuit Breaker Vl160n Standard Breaking Capacity Icu=55ka, 415v Ac 4-pole, Line Protection Electronic Trip Unit Tm, Li In=160a, Rated Current Ir=125...160a, Overload Protection, Ii=800...1600a, Short-circuit Protection N Protected Undervoltage Re
- Available
Trusted by…
Trusted by industry leaders
Trusted by industry leaders