- Part Number
- Description
- Availability
-
- 3VL2716-2DC36-0AA0
- Circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=160A, rated current IR=125...160A, overload protection, II=800...1600A, short-circuit protection with screw terminals without auxiliary release without auxiliary/alarm switch
- Available
-
- 3VL2716-2DC36-0AB1
- Circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=160A, rated current IR=125...160A, overload protection, II=800...1600A, short-circuit protection with screw terminals without auxiliary release Auxiliary switch mounting kit 2 AUXILIARY (1 NO + 1 NC)
- Available
-
- 3VL2716-2DC36-2HA0
- Circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit TM, LI In=160A, rated current IR=125...160A, overload protection, II=800...1600A, short-circuit protection with screw terminals Undervoltage release 220...250 V AC without auxiliary/alarm switch
- Available
-
- 3VL2716-2DC36-2JD1
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Line Protection Electronic Trip Unit Tm, Li In=160a, Rated Current Ir=125...160a, Overload Protection, Ii=800...1600a, Short-circuit Protection With Screw Terminals Undervolta
- Available
-
- 3VL2716-2DE33-0AA0
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Non-auto. Air Circuit Breaker Electronic Trip Unit Magnetic In=160a, Rated Current Ii=2500a, Short-circuit Protection Without Auxiliary Release Without Auxiliary/alarm Switch
- Available
-
- 3VL2716-2DE36-2HA0
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Non-auto. Air Circuit Breaker Electronic Trip Unit Magnetic In=160a, Rated Current Ii=2500a, Short-circuit Protection With Screw Terminals Undervoltage Release 220...250 V Ac Withou
- Available
-
- 3VL2716-2DK33-0AA0
- Circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, starter combination Trip Unit magnetic In=160A, rated current II=1250...2500A, short-circuit protection without auxiliary release without auxiliary/alarm switch
- Available
-
- 3VL2716-2DK33-0AB1
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Starter Combination Electronic Trip Unit Magnetic In=160a, Rated Current Ii=1250...2500a, Short-circuit Protection Without Auxiliary Release Auxiliary Switch Mounting Kit 2 Au
- Available
-
- 3VL2716-2DK33-0AD1
- Circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, starter combination Trip Unit magnetic In=160A, rated current II=1250...2500A, short-circuit protection without auxiliary release Auxiliary/alarm switch mounting kit 2 AUXILIARY (1 NO+1 NC) +1 AS (1 NO)
- Available
-
- 3VL2716-2DK33-8TD1
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Starter Combination Electronic Trip Unit Magnetic In=160a, Rated Current Ii=1250...2500a, Short-circuit Protection Shunt Release 208...277 V Ac Auxiliary/alarm Switch Mounting
- Available
-
- 3VL2716-2DK36-0AA0
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Starter Combination Electronic Trip Unit Magnetic In=160a, Rated Current Ii=1250...2500a, Short-circuit Protection With Screw Terminals Without Auxiliary Release Without Auxil
- Available
-
- 3VL2716-2DK36-0AB1
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Starter Combination Electronic Trip Unit Magnetic In=160a, Rated Current Ii=1250...2500a, Short-circuit Protection With Screw Terminals Without Auxiliary Release Auxiliary Swi
- Available
-
- 3VL2716-2DK36-2JA0
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Starter Combination Electronic Trip Unit Magnetic In=160a, Rated Current Ii=1250...2500a, Short-circuit Protection With Screw Terminals Undervoltage Release 380...415 V Ac Wit
- Available
-
- 3VL2716-2EC43-0AB1
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 4-pole, Line Protection Electronic Trip Unit Tm, Li In=160a, Rated Current Ir=125...160a, Overload Protection, Ii=800...1600a, Short-circuit Protection N Protected Without Auxiliary R
- Available
-
- 3VL2716-2EE43-0AA0
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 4-pole, Non-auto. Air Circuit Breaker Electronic Trip Unit Magnetic In=160a, Rated Current Ii=2500a, Short-circuit Protection Without Auxiliary Release Without Auxiliary/alarm Switch
- Available
-
- 3VL2716-2EJ43-0AA0
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 4-pole, Line Protection Electronic Trip Unit Tm, Li In=160a, Rated Current Ir=125...160a, Overload Protection, Ii=800...1600a, Short-circuit Protection N Unprotected Without Auxiliary
- Available
-
- 3VL2716-2MP33-0AB1
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Motor/generator Protection Electronic Trip Unit Etu10m, Li In=160a, Rated Current Ir=64...160a, Overload Protection, Ii=1.25 To 11xin, Short-circuit Protection Without Auxiliary Re
- Available
-
- 3VL2716-2SB36-0AA0
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Line Protection Electronic Trip Unit Etu10, Li In=160a, Rated Current Ir=64...160a, Overload Protection, Ii=1.25 To 11xin, Short-circuit Protection With Screw Terminals Withou
- Available
-
- 3VL2716-2SE36-0AA0
- Circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection Trip Unit ETU20, LSI In=160A, rated current IR=64...160A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection with screw terminals without auxiliary release without auxiliary/alarm switch
- Available
-
- 3VL2716-2SF33-0AB1
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Line Protection Electronic Trip Unit Etu12, Lig 3 Phases/4 Lines In=160a, Rated Current Ir=64...160a, Overload Protection, Ii=1.25 To 11xin, Short-circuit Protection Without A
- Available
-
- 3VL2716-2SP33-0AA0
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Motor/generator Protection Electronic Trip Unit Etu10m, Li In=160a, Rated Current Ir=64...160a, Overload Protection, Ii=1.25 To 11xin, Short-circuit Protection Without Auxiliary Re
- Available
-
- 3VL2716-2SP33-0AB1
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Motor/generator Protection Electronic Trip Unit Etu10m, Li In=160a, Rated Current Ir=64...160a, Overload Protection, Ii=1.25 To 11xin, Short-circuit Protection Without Auxiliary Re
- Available
-
- 3VL2716-2SP36-0AB1
- Circuit breaker VL160H high breaking capacity Icu=70kA, 415V AC 3-pole, motor/generator protection Electronic Trip Unit ETU10M, LI In=160A, rated current IR=64...160A, overload protection, II=1.25 to 11xIN, short-circuit protection with screw terminals without auxiliary release Auxiliary switch mounting kit 2 AUXILIARY (1 NO + 1 NC)
- Available
-
- 3VL2716-2SP36-0AD1
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Motor/generator Protection Electronic Trip Unit Etu10m, Li In=160a, Rated Current Ir=64...160a, Overload Protection, Ii=1.25 To 11xin, Short-circuit Protection With Screw Terminals
- Available
-
- 3VL2716-2SS33-0AA0
- Circuit Breaker Vl160h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Motor Protection Electronic Trip Unit Etu30m, Li Ir=63...160a, Overload Protection, Tc=10a...30, Ii=6/8/11 Xin, Short-circuit Protection Without Auxiliary Release Without Auxiliary
- Available
Trusted by…