- Part Number
- Description
- Availability
-
- 3VL5750-1EJ46-0AE1
- Circuit Breaker Vl630n Standard Breaking Capacity Icu=55ka, 415v Ac 4-pole, Line Protection Trip Unit Tm, Li In=500a, Rated Current Ir=400...500a, Overload Protection, Ii=2500...5000a, Short-circuit Protection N Unprotected Without Auxiliary Relea
- Available
-
- 3VL5750-1EJ46-8CC1
- Circuit Breaker Vl630n Standard Breaking Capacity Icu=55ka, 415v Ac 4-pole, Line Protection Trip Unit Tm, Li In=500a, Rated Current Ir=400...500a, Overload Protection, Ii=2500...5000a, Short-circuit Protection N Unprotected Shunt Release 24 V Ac/d
- Available
-
- 3VL5750-1EM46-0AA0
- Circuit Breaker Vl630n Standard Breaking Capacity Icu=55ka, 415v Ac 4-pole, Line Protection Tu, Tm, Li In=500a, Rated Current Ir=400...500a, Overload Protection Ii=2500...5000a, Short-circuit Protection N Protected (100%) Without Auxiliary Release With
- Available
-
- 3VL5750-1MS36-0AC1
- Circuit breaker VL630N standard breaking capacity Icu=55kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=200...500A, overload protection, TC=10A...30, II=6/8/12.5xIN, short-circuit protection without auxiliary release ETU communication-capable Auxiliary switch installation kit 4 AUXILIARY (2 NO + 2 NC)
- Available
-
- 3VL5750-1SP36-0AA0
- Circuit Breaker Vl630n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Motor/generator Protection Trip Unit Etu10m, Li In=500a, Rated Current Ir=200...500a, Overload Protection, Ii=1.25 To 12.5xin, Short-circuit Protection Without Auxiliary Releas
- Available
-
- 3VL5750-1SS36-0AA0
- Circuit Breaker Vl630n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Motor Protection Electronic Trip Unit Etu30m, Li Ir=200...500a, Overload Protection, Tc=10a...30, Ii=6/8/12.5xin, Short-circuit Protection Without Auxiliary Release Without Aux
- Available
-
- 3VL5750-1SS36-0AC1
- Circuit Breaker Vl630n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Motor Protection Electronic Trip Unit Etu30m, Li Ir=200...500a, Overload Protection, Tc=10a...30, Ii=6/8/12.5xin, Short-circuit Protection Without Auxiliary Release Auxiliary S
- Available
-
- 3VL5750-1SS36-0AE1
- Circuit Breaker Vl630n Standard Breaking Capacity Icu=55ka, 415v Ac 3-pole, Motor Protection Electronic Trip Unit Etu30m, Li Ir=200...500a, Overload Protection, Tc=10a...30, Ii=6/8/12.5xin, Short-circuit Protection Without Auxiliary Release Auxiliary/a
- Available
-
- 3VL5750-2AP36-0AA0
- Circuit-breaker Vl 630h High Switching C
- Low Stock
-
- 3VL5750-2AP36-0AC1
- Circuit-breaker Vl 630h High Switching C
- Low Stock
-
- 3VL5750-2AP36-0AE1
- Circuit-breaker Vl 630h High Switching C
- Low Stock
-
- 3VL5750-2DC36-0AA0
- Circuit Breaker Vl630h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Line Protection Trip Unit Tm, Li In=500a, Rated Current Ir=400...500a, Overload Protection, Ii=2500...5000a, Short-circuit Protection Without Auxiliary Release Without Auxilia
- Available
-
- 3VL5750-2DC36-0AC1
- Circuit Breaker Vl630h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Line Protection Trip Unit Tm, Li In=500a, Rated Current Ir=400...500a, Overload Protection, Ii=2500...5000a, Short-circuit Protection Without Auxiliary Release Auxiliary Switc
- Available
-
- 3VL5750-2DC36-0AE1
- Circuit Breaker Vl630h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Line Protection Trip Unit Tm, Li In=500a, Rated Current Ir=400...500a, Overload Protection, Ii=2500...5000a, Short-circuit Protection Without Auxiliary Release Auxiliary/alarm
- Available
-
- 3VL5750-2DC36-2GA0
- Circuit Breaker Vl630h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Line Protection Trip Unit Tm, Li In=500a, Rated Current Ir=400...500a, Overload Protection, Ii=2500...5000a, Short-circuit Protection Undervoltage Release 110...127 V Ac Witho
- Available
-
- 3VL5750-2DC36-8VA0
- Circuit Breaker Vl630h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Line Protection Trip Unit Tm, Li In=500a, Rated Current Ir=400...500a, Overload Protection, Ii=2500...5000a, Short-circuit Protection Shunt Release 380...600 V Ac Without Auxi
- Available
-
- 3VL5750-2DK36-0AA0
- Circuit Breaker Vl630h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Starter Combination Trip Unit Magnetic In=500a, Rated Current Ii=3250...6300a, Short-circuit Protection Without Auxiliary Release Without Auxiliary/alarm Switch
- Available
-
- 3VL5750-2DK36-0AC1
- Circuit Breaker Vl630h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Starter Combination Trip Unit Magnetic In=500a, Rated Current Ii=3250...6300a, Short-circuit Protection Without Auxiliary Release Auxiliary Switch Mounting Kit 4 Auxiliary (2 No + 2
- Available
-
- 3VL5750-2DK36-0AE1
- Circuit Breaker Vl630h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Starter Combination Trip Unit Magnetic In=500a, Rated Current Ii=3250...6300a, Short-circuit Protection Without Auxiliary Release Auxiliary/alarm Switch Mounting Kit 2 Auxiliary (1
- Available
-
- 3VL5750-2DK36-2GE1
- Circuit Breaker Vl630h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Starter Combination Trip Unit Magnetic In=500a, Rated Current Ii=3250...6300a, Short-circuit Protection Undervoltage Release 110...127 V Ac Auxiliary/alarm Switch Mounting Kit
- Available
-
- 3VL5750-2EC46-0AA0
- Circuit Breaker Vl630h High Breaking Capacity Icu=70ka, 415v Ac 4-pole, Line Protection Trip Unit Tm, Li In=500a, Rated Current Ir=400...500a, Overload Protection, Ii=2500...5000a, Short-circuit Protection N Protected Without Auxiliary Release Wit
- Available
-
- 3VL5750-2EJ46-0AA0
- Circuit Breaker Vl630h High Breaking Capacity Icu=70ka, 415v Ac 4-pole, Line Protection Trip Unit Tm, Li In=500a, Rated Current Ir=400...500a, Overload Protection, Ii=2500...5000a, Short-circuit Protection N Unprotected Without Auxiliary Release W
- Available
-
- 3VL5750-2EJ46-8KE1
- Circuit Breaker Vl630h High Breaking Capacity Icu=70ka, 415v Ac 4-pole, Line Protection Trip Unit Tm, Li In=500a, Rated Current Ir=400...500a, Overload Protection, Ii=2500...5000a, Short-circuit Protection N Unprotected Shunt Release 110...127 V D
- Available
-
- 3VL5750-2SP36-0AA0
- Circuit Breaker Vl630h High Breaking Capacity Icu=70ka, 415v Ac 3-pole, Motor/generator Protection Trip Unit Etu10m, Li In=500a, Rated Current Ir=200...500a, Overload Protection, Ii=1.25 To 12.5xin, Short-circuit Protection Without Auxiliary Release Wi
- Available
-
- 3VL5750-2SS36-0AC1
- Circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=200...500A, overload protection, TC=10A...30, II=6/8/12.5xIN, short-circuit protection without auxiliary release Auxiliary switch mounting kit 4 AUXILIARY (2 NO + 2 NC)
- Available
Trusted by…