- Part Number
- Description
- Availability
-
- 3VT1708-2EB46-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole; starter combination trip unit tm, lin in=80a rated current II=400.800A, short-circuit protection n conductor unprotected without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1708-2EC45-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole, line protection trip unit tm, li in=80a rated current IR=63.80A overload protection II=400.800A, short-circuit protection n conductor unprotected without auxiliary release without auxiliary/alarm switch with front terminals.
- Available
-
- 3VT1708-2EC46-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole, line protection trip unit tm, li in=80a rated current IR=63.80A overload protection II=400.800A, short-circuit protection n conductor unprotected without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1708-2EG46-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole; starter combination trip unit tm, lin in=80a rated current II=400.800A, short-circuit protection n conductor protected without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1708-2EH46-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole, line protection trip unit tm, lin in=80a rated current IR=80a overload protection II=320a, short-circuit protection N conductor protected without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1708-2EJ46-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole, line protection trip unit tm, lin in=80a rated current IR=63.80A overload protection II=400.800A, short-circuit protection n conductor protected without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1710-2DA35-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 3-pole, line protection trip unit tm, li in=100A rated current IR=100A overload protection II=400A, short-circuit prot, without auxiliary release without auxiliary/alarm switch with front terminals.
- Available
-
- 3VT1710-2DA36-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 3-pole, line protection trip unit tm, li in=100A rated current IR=100A overload protection II=400A, short-circuit prot, without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1710-2DB35-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 3-pole; starter combination trip unit tm, lin in=100A rated current II=500.1000A, short-circuit protection without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1710-2DB36-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 3-pole, line protection trip unit tm, li in=100A rated current IR=80.100A overload protection Ii=500.1000A, short-circuit protection without auxiliary release without auxiliary/alarm switch with front terminals.
- Available
-
- 3VT1710-2DC35-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 3-pole, line protection trip unit tm, li in=100A rated current IR=80.100A overload protection Ii=500.1000A, short-circuit protection without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1710-2DC36-0AA0
- Circuit breaker with standard breaking capacity.
- Available
-
- 3VT1710-2DM35-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 3-pole, motor protection trip unit tm, li in=100A rated current IR=80.100A overload protection Ii=1000a, short-circuit prot, without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1710-2DM36-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole, line protection trip unit tm, li in=100A rated current IR=100A overload protection II=400A, short-circuit protection N conductor unprotected without auxiliary release without auxiliary/alarm switch with front terminals.
- Available
-
- 3VT1710-2EA45-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole, line protection trip unit tm, li in=100A rated current IR=100A overload protection II=400A, short-circuit protection N conductor unprotected without auxiliary release without auxiliary/alarm switch with front terminals.
- Available
-
- 3VT1710-2EA46-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole, line protection trip unit tm, li in=100A rated current IR=100A overload protection II=400A, short-circuit protection N conductor unprotected without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1710-2EB46-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole; starter combination trip unit tm, lin in=100A rated current II=500.1000A, short-circuit protection n conductor unprotected without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1710-2EC45-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole, line protection trip unit tm, li in=100A rated current IR=80.100A overload protection Ii=500.1000A, short-circuit protection n conductor unprotected without auxiliary release without auxiliary/alarm switch with front terminals.
- Available
-
- 3VT1710-2EC46-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole, line protection trip unit tm, li in=100A rated current IR=80.100A overload protection Ii=500.1000A, short-circuit protection n conductor unprotected without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1710-2EG46-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole; starter combination trip unit tm, lin in=100A rated current II=500.1000A, short-circuit protection n conductor protected without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1710-2EH46-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole, line protection trip unit tm, lin in=100A rated current IR=100A overload protection II=400A, short-circuit protection N conductor protected without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1710-2EJ46-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 4-pole, line protection trip unit tm, lin in=100A rated current IR=80.100A overload protection Ii=500.1000A, short-circuit protection n conductor protected without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1712-2DA35-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 3-pole, line protection trip unit tm, li in=125A rated current IR=125A overload protection II=500a, short-circuit prot, without auxiliary release without auxiliary/alarm switch with front terminals.
- Available
-
- 3VT1712-2DA36-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 3-pole, line protection trip unit tm, li in=125A rated current IR=125A overload protection II=500a, short-circuit prot, without auxiliary release without auxiliary/alarm switch.
- Available
-
- 3VT1712-2DB36-0AA0
- Circuit breaker 3VT1 standard breaking capacity ICU=25ka, 415V ac 3-pole; starter combination trip unit tm, lin in=125A rated current II=625.1250A, short-circuit protection without auxiliary release without auxiliary/alarm switch.
- Available