-
- Part Number
- Description
- Availability
-
- 3WL1240-3CB47-1AA2
- Withdrawable Circuit Breaker With Guide Frame 4-pole, Size Ii, Iec In=4000a To 690v, Ac50/60hz Icu=80ka At 500v Rear Connection Vertical Overcurrent Release Etu 25 Lsi Protection Adjustable 0.4-1 In With Manual Operating Mechanism With Storage Wit
- Available
-
- 3WL1240-3EG41-1AA2
- Fixed-mounted Circuit Breaker 4-pole, Size Ii, Iec In=4000a To 690v, Ac50/60hz Icu=80ka At 500v Rear Connection Vertical Overcurrent Release Etu 45 Lsing Protection Adjustable 0.4-1 In With Cubicle Bus And Ground Fault Protection Opt.: Comm./measu
- Available
-
- 3WL1240-3EG47-1FF4
- Withdrawable Circuit Breaker With Guide Frame 4-pole, Size Ii, Iec In=4000a To 690v, Ac50/60hz Icu=80ka At 500v Rear Connection Vertical Overcurrent Release Etu 45 Lsing Protection Adjustable 0.4-1 In With Cubicle Bus And Ground Fault Protection O
- Available
-
- 3WL1240-4EG45-1AA4
- Draw-out Circuit Breaker Without Guide Frame 4-pole, Size Ii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Terminals Horizontal Overcurrent Release Etu 45 Lsing Protection Adjustable 0.4-1 In With Cubicle Bus And Ground Fault Protection
- Available
-
- 3WL1240-4NB31-1AA2
- Fixed-mounted Circuit Breaker 3-pole, Size Ii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Vertical Overcurrent Release Etu 76 Lsi Protection Adjustable 0.4-1 In With Graphic Display U Cubicle Bus Communication/ground Fault/
- Available
-
- 3WL1340-4AA37-4GS2
- withdrawable Non-aut. Circuit-b. With Guide Frame 3-pole, Size Iii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Vertical Without Overcurrent Release Motorized/manual Operating Mechanism With Spring Charging Motor Ac 50/60 Hz 208
- Available
-
- 3WL1340-4AA45-5FA4
- withdrawable non-aut. circuit-b. without guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal without overcurrent release Motorized/manual operating mechanism with spring charging motor AC 50/60 Hz 110-127 V AC or 110-125 V DC Activation 50/60 Hz 110 V AC, 110 V DC With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 4NO+4NC
- Available
-
- 3WL1340-4CB32-5FA4
- Fixed-mounted Circuit Breaker 3-pole, Size Iii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Horizontal Overcurrent Release Etu 25 Lsi Protection Adjustable 0.4-1 In Motorized/manual Operating Mechanism With Spring Charging Mo
- Available
-
- 3WL1340-4CB35-4GA2
- Withdrawable Circuit Breaker Without Guide Frame 3-pole, Size Iii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Horizontal Overcurrent Release Etu 25 Lsi Protection Adjustable 0.4-1 In Motorized/manual Operating Mechanism With
- Available
-
- 3WL1340-4CB36-4GN4
- Withdrawable Circuit Breaker With Guide Frame 3-pole, Size Iii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Horizontal Overcurrent Release Etu 25 Lsi Protection Adjustable 0.4-1 In Motorized/manual Operating Mechanism With Sp
- Available
-
- 3WL1340-4CB41-1AA2-Z-T40
- Fixed Mount 3p Air Circuit Breaker In=4000a
- Available
-
- 3WL1340-4CB46-4GA2
- Withdrawable Circuit Breaker With Guide Frame 4-pole, Size Iii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Horizontal Overcurrent Release Etu 25 Lsi Protection Adjustable 0.4-1 In Motorized/manual Operating Mechanism With Sp
- Available
-
- 3WL1340-4CB46-4GA4
- Withdrawable Circuit Breaker With Guide Frame 4-pole, Size Iii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Horizontal Overcurrent Release Etu 25 Lsi Protection Adjustable 0.4-1 In Motorized/manual Operating Mechanism With Sp
- Available
-
- 3WL1340-4DG32-1AA2
- Fixed-mounted Circuit Breaker 3-pole, Size Iii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Horizontal Overcurrent Release Etu 27 Lsing Protection Adjustable 0.4-1 In Ground Fault/n Protection Integrated With Manual Operating
- Available
-
- 3WL1340-4DG32-1FA2
- Fixed-mounted circuit breaker 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU 27 LSING protection adjustable 0.4-1 in Ground fault/N protection integrated With manual operating mechanism with storage with mechanical request With 1st auxiliary release Shunt release "F", F1 50/60 Hz 110 V AC/110 V DC, 100% on-load factor without 2nd auxiliary release 2NO+2NC
- Available
-
- 3WL1340-4DG35-4GP2
- Withdrawable Circuit Breaker Without Guide Frame 3-pole, Size Iii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Horizontal Overcurrent Release Etu 27 Lsing Protection Adjustable 0.4-1 In Ground Fault/n Protection Integrated Mo
- Available
-
- 3WL1340-4DG45-1AA4
- Withdrawable Circuit Breaker Without Guide Frame 4-pole, Size Iii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Horizontal Overcurrent Release Etu 27 Lsing Protection Adjustable 0.4-1 In Ground Fault/n Protection Integrated Wi
- Available
-
- 3WL1340-4DG45-1CA2
- Withdrawable Circuit Breaker Without Guide Frame 4-pole, Size Iii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Horizontal Overcurrent Release Etu 27 Lsing Protection Adjustable 0.4-1 In Ground Fault/n Protection Integrated Wi
- Available
-
- 3WL1340-4EB31-6BA2
- Fixed-mounted Circuit Breaker 3-pole, Size Iii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Vertical Overcurrent Release Etu45 Lsin Protection Adjustable 0.4-1 In With Cubicle Bus Opt.: Comm./measuring Func./ground Fault/Zs
- Available
-
- 3WL1340-4EB32-1AG2
- Fixed-mounted Circuit Breaker 3-pole, Size Iii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Horizontal Overcurrent Release Etu45 Lsin Protection Adjustable 0.4-1 In With Cubicle Bus Opt.: Comm./measuring Func./ground Fault/
- Available
-
- 3WL1340-4EB45-5FA4-Z
- Withdrawable circuit breaker without guide frame 4-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal
- Available
-
- 3WL1340-4EG41-1GA2
- Fixed-mounted Circuit Breaker 4-pole, Size Iii, Iec In=4000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Vertical Overcurrent Release Etu 45 Lsing Protection Adjustable 0.4-1 In With Cubicle Bus And Ground Fault Protection Opt.: Comm./mea
- Available
-
- 3WL1340-4FB35-4AS4
- Withdrawable circuit breaker without guide frame 3-pole, size III, IEC In=4000A to 690V, AC50/60Hz Icu=100kA at 500V rear connection horizontal Overcurrent release ETU45 LSIN protection adjustable 0.4-1 in with display and cubicle bus Opt.: Comm./measuring func./ground fault/ZSS Motorized/manual operating mechanism with spring charging motor AC 50/60Hz 208-240 V or 220-250 V DC Activation AC 50/60Hz 230 V, 220 V DC without 1st auxiliary release With 2nd auxiliary release "RC", F4 Undervoltage, Delay 0.2-3.2s 208-240 V AC, 220-250 V DC, 100% ED 4NO+4NC
- Available
-
- 3WL1340-5CB31-1AA2
- Fixed-mounted Circuit Breaker 3-pole, Size Iii, Iec In=4000a To 1150v, Ac50/60hz Icu=150ka At 500v Rear Connection Vertical Overcurrent Release Etu 25 Lsi Protection Adjustable 0.4-1 In With Manual Operating Mechanism With Storage With Mechanical
- Available
-
- 3WL1350-4AA31-3GN2
- Fixed-mount Non-aut. Circuit-b. 3-pole, Size Iii, Iec In=5000a To 690v, Ac50/60hz Icu=100ka At 500v Rear Connection Vertical Without Overcurrent Release With Manual Operating Mechanism With Storage With Electrical + Mechanical Request 50/60 Hz 230
- Available
Trusted by…
Trusted by industry leaders
Trusted by industry leaders