- 5SD7483-6
- Surge arrester T1/T2, UC 1050V DC, Imax 40 kA Short-circuit strength 80 A, 2+V circuit, for isolated and grounded PV systems
- Available
-
- 5SD7485-0
- Surge Arrester Type 2 Requirement Cat. C
- Available
-
- 5SD7488-0
- Plug-in part type 2 N-PE Requirement class C, UC 260V 1-pole for surge arrester 5SD746..., 5SD747..., 5SD7481-0
- Available
-
- 5SD7488-1
- Plug-in part type 2 L-N UC 440 V, Imax 40 kA, Type 2, Class II, Requirement class C, 1-pole, can be used with all surge arresters 5SD74 in overall width 18 mm
- Available
-
- 5SD7488-2
- Plug-in part type 2, UC 750V AC, for 5SD7481-1 and 5SD7483-5
- Available
-
- 5SD7488-4
- Plug-in part for 5SD7481-1
- Available
-
- 5SD7490-1
- Through-type Terminal F. 1-pole Surge Arr
- Available
-
- 5SD7490-4
- Busbar 4-poles For Mounting 4x 1-pole Surg
- Available
-
- 5SD7490-5
- Assembly set for 3 units Lightning arrester 5SD74112
- Available
-
- 5SD7498-1
- Plug-in part type 2 L-N UC 580V, Imax 30 kA, Type 2, Class II, Requirement class C, 1-pole, can be used with all surge arresters 5SD74 in overall width 18 mm
- Available
-
- 5SD7498-2
- Plug-in part type 2 UAG>1100CV DC, Imax 30 kA Class II, Requirement class C Overall width 18 mm only for 5SD748-3 and 5SD7483-4
- Available
-
- 5SD7498-3
- Plug-in part T1/T2 for 5SD7483-6 and 5SD7483-7
- Available
-
- 5SD7502-0KB
- Overvoltage protective device for 2 single-sided grounded signal cables UC=68 V DC/48 V AC, Test class C1, C2, C3, D1, gas discharge tube between the connections 3-4 (GND) and 9-10
- Available
-
- 5SD7522-7KA
- Overvoltage protective device for 2 two-wire ground-potential-free signal circuits, UC=40V DC/28V AC Test class C1, C2, C3, D1, gas discharge tube between the connections 3-4 (GND) and 9-10
- Available
-
- 5SD7522-7KB
- Overvoltage protective device for 2 two-wire ground-potential-free signal circuits, UC=40V DC/28V AC Test class C1, C2, C3, D1, jumper between the connections 3-4 (GND) and 9-10
- Available
-
- 5SD7530-4KA
- Overvoltage protective device for 2 ground-potential-free signal insulated conductors and ground, UC=14V DC/9.8V AC Test class C1, C2, C3, D1, gas discharge tube between the connections 3-4 (GND) and 9-10
- Available
-
- 5SD7530-4KB
- Overvoltage protective device for 2 ground-potential-free signal insulated conductors and ground, UC=14V DC/9.8V AC Test class C1, C2, C3, D1, jumper between the connections 3-4 (GND) and 9-10
- Available
-
- 5SD7540-6KB
- Overvoltage protective device for a 4-core DIN rail operated without ground signal circuit, UC=27V DC/19V AC, Test class C1, C2, C3, D1, jumper between the connections 3-4 (GND) and 9-10
- Available
-
- 5SD7541-7KB
- Overvoltage protective device for 4-wire, single-sided grounded signal circuits, UC=40V DC/28V AC, Test class C1, C2, C3, D1, jumper between the connections 3-4 (GND) and 9-10
- Available
-
- 5SD7550-4KA
- Overvoltage protective device for a 4-core DIN rail operated without ground signal circuit, UC=12.8V DC/9V AC, Test class C1, C2, C3, D1, gas discharge tube between the connections 3-4 (GND) and 9-10
- Available
-
- 5SD7550-4KB
- Overvoltage protective device for a 4-core DIN rail operated without ground signal circuit, UC=12.8V DC/9V AC, Test class C1, C2, C3, D1, jumper between the connections 3-4 (GND) and 9-10
- Available
-
- 5SD7581-2
- Overvoltage protection for analog and digital telecommunication inter- faces, connection: RJ45 connection: RJ45 (RJ12/RJ11)
- Available
-
- 5SD7581-3
- Overvoltage protection for Ethernet interfaces up to 10 Gbit/s, including POE
- Available
-
- 5SD7581-5
- D-sub-9-intermediate connector with overvoltage protection for RS-485 interfaces
- Available
-
- 5SD7581-6
- D-sub-9-intermediate connector with overvoltage protection for RS-232-C interface
- Available