- Part Number
- Description
- Availability
-
- CIMR-AT4A0058FAA
- Available
-
- CIMR-AT4A0072AAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 37kW (Normal duty) /50HP (Normal duty), Rated output current 72A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0072FAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 37kW (Normal duty) /50HP (Normal duty), Rated output current 72A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0088AAA
- Available
-
- CIMR-AT4A0088FAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 45kW (Normal duty) /60HP (Normal duty), Rated output current 88A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0103AAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 55kW (Normal duty) /75HP (Normal duty), Rated output current 103A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0103FAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 55kW (Normal duty) /75HP (Normal duty), Rated output current 103A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0139AAA
- Available
-
- CIMR-AT4A0139FAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 75kW (Normal duty) /100HP (Normal duty), Rated output current 139A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0165AAA
- Available
-
- CIMR-AT4A0165FAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 90kW (Normal duty) /125HP (Normal duty), Rated output current 165A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0208AAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 110kW (Normal duty) /150HP (Normal duty), Rated output current 208A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0208FAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 110kW (Normal duty) /150HP (Normal duty), Rated output current 208A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0250AAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 132kW (Normal duty) /200HP (Normal duty), Rated output current 250A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0250FAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 132kW (Normal duty) /200HP (Normal duty), Rated output current 250A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0296AAA
- Available
-
- CIMR-AT4A0296FAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 160kW (Normal duty) /250HP (Normal duty), Rated output current 296A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0362AAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 185kW (Normal duty) /300HP (Normal duty), Rated output current 362A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0362FAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 185kW (Normal duty) /300HP (Normal duty), Rated output current 362A (Normal duty), frequency (output) 0.01-400Hz, IP20/NEMA 1, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0414AAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 220kW (Normal duty) /350HP (Normal duty), Rated output current 414A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0515AAA
- Available
-
- CIMR-AT4A0675AAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 450kW (Normal duty) /600HP (Normal duty), Rated output current 675A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A0930AAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 560kW (Normal duty) /800HP (Normal duty), Rated output current 930A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AT4A1200AAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 380Vac-480Vac (400Vac/415Vac/440Vac), Rated active power 630kW (Normal duty) /1000HP (Normal duty), Rated output current 1200A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Forced ventilation (Fan-cooling) (Standard heatsink fins) - with Integrated DC choke, 3-phase 480V class
- Available
-
- CIMR-AU2A0004AAA
- A1000 Series Inverter Drive, Input voltage (3-phase (3P)) 200Vac-240Vac (208Vac/220Vac/230Vac), Rated active power 3/4HP (Normal duty), Rated output current 3.5A (Normal duty), frequency (output) 0.01-400Hz, IP00, with RS-422 + RS-485 communication capablilty, Wall mounting, Standard heatsink fins, 3-phase 240V class
- Available