- Part Number
- Description
- Availability
-
- X20cPS9600
- The power supply module is used together with an X20 Compact-S CPU. It has a feed for the Compact-S CPU, X2X Link and the internal I/O power supply.
- Available
-
- X20CS1011
- SmartWire from the company Moeller makes it possible to very easily integrate switching devices such as contactors or motor protection switches in the X20 system without extensive wiring. It replaces the control circuit wiring between the controller and switching devices with pluggable, pre-assembled connection cables. Although SmartWire is an intelligent connection, this changes almost nothing for the machine programmer. Integration in the X20 system via the interface module cuts down on overall communication. The individual switching devices can simply be viewed as digital inputs and outputs. Practical applications SmartWire allows up to 16 switching devices to be connected using pre-assembled cables and attached to the X20 SmartWire interface module. The system can configure itself completely at the push of a button without additional intervention or effort. This replaces the wiring test that was previously necessary. At the same time, the device configuration is known to the system. If a device is no longer available due to an error or intervention, it will be detected immediately. Once corrected, the system continues to run. The interface module is designed as a normal electronic module, which means it can be placed anywhere on the remote backplane.
- Available
-
- X20CS1012
- The M-Bus master is designed as a single-width module and can be connected anywhere within the X20 I/O system. It can therefore be used decentrally for distributed topologies. The M-Bus master supports transfer rates of 300, 2400 and 9600 bit/s; up to 64 slaves supplied via M-Bus can be connected. M-Bus (Meter-Bus) is a relatively simple fieldbus for recording consumption data, such as from electricity or heat meters. It is based on a reverse polarity protected two-wire line and works according to the master-slave principle.
- Available
-
- X20CS1013
- The module is a DALI control device with an integrated power supply. Up to 64 operating devices can be connected. DALI stands for Digital Addressable Lighting Interface and enables easy and safe control of light fixtures using a standardized digital operating device interface. The DALI bus conforms with EN 62386 series of standards and is now supported by many electronic ballast manufacturers.
- Available
-
- X20CS1020
- In addition to the standard I/O, complex devices often need to be connected. The X20CS communication modules are intended precisely for cases like this. As normal X20 electronics modules, they can be placed anywhere on the remote backplane.
- Available
-
- X20CS1030
- In addition to the standard I/O, complex devices often need to be connected. The X20CS communication modules are intended precisely for cases like this. As normal X20 electronics modules, they can be placed anywhere on the remote backplane.
- Available
-
- X20CS1070
- In addition to the standard I/O, complex devices often need to be connected. The X20CS communication modules are intended precisely for cases like this. As normal X20 electronics modules, they can be placed anywhere on the remote backplane.
- Available
-
- X20CS2770
- In addition to the standard I/O, complex devices often need to be connected. The X20 CS communication modules are intended precisely for cases like this. As normal X20 electronics modules, they can be placed anywhere on the remote backplane.
- Available
-
- X20CS2770-C01
- Communication Module
- Available
-
- X20cSA4430
- The module is equipped with 2 safe analog input pairs for current measurement. Each input pair has its own sensor power supply. The channels with their respective sensor supplies are electrically isolated from each other. It can be used to capture current signals in the range from 0.5 to 25 mA. The safe analog input module is suitable for safely acquiring current signals for safety-related applications up to PL e or SIL 3. This module is designed for X20 16-pin terminal blocks.
- Available
-
- X20cSC2212
- The module is equipped with 6 safe digital inputs and 2 safe digital outputs. It is designed for a nominal voltage of 24 VDC. The module can be used to read in digital signals and to control actuators in safety-related applications up to PL e or SIL 3. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side high-side" variant (output type B) is required for actuators with reference potential (e.g. Enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.
- Available
-
- X20cSC2432
- The module is equipped with 2 safe digital inputs and 2 safe relay outputs. It is designed for a nominal voltage of 24 VDC. The module can be used to read digital signals and for floating control of actuators in safety-related applications up to PL e or SIL 3. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. Safety relays are installed in the module. The positively driven feedback contacts are evaluated internally by the module. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.
- Available
-
- X20cSD1207
- This module is equipped with 1 safe digital input for determining the velocity. Velocity information can be acquired from AB signals up to a maximum frequency of 7 kHz. The safe counter module is suitable for safely acquiring velocities for safety-related applications up to PL e or SIL 3. This module is designed for X20 12-pin terminal blocks.
- Available
-
- X20cSI4100
- This module is equipped with 4 safe digital inputs. It is designed for a nominal voltage of 24 VDC. The module can be used to read various digital signals in safety-related applications up to PL e or SIL 3. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. This module is designed for X20 12-pin terminal blocks.
- Available
-
- X20cSI9100
- This module is equipped with 20 safe digital inputs. It is designed for a nominal voltage of 24 VDC. The module can be used to read various digital signals in safety-related applications up to PL e or SIL 3. The module is equipped with filters that are individually configurable for switch-on and switch-off behavior. The module also provides pulse signals for diagnosing the sensor line. This module is designed for X20 12-pin terminal blocks.
- Available
-
- X20cSL8100
- The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3. In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed by the SafeLOGIC controller.
- Available
-
- X20cSL8101
- The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3. In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed by the SafeLOGIC controller.
- Available
-
- X20cSLX402
- The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3. In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed in conjunction with Automation Runtime on the standard CPU. In addition, SafeLOGIC-X products have the same I/O properties as the associated SafeIO products (X20SC0xxx).
- Available
-
- X20cSLX410
- The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3. In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed in conjunction with Automation Runtime on the standard CPU. In addition, SafeLOGIC-X products have the same I/O properties as the associated SafeIO products (X20SIx1x0).
- Available
-
- X20cSLX910
- The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3. In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed in conjunction with Automation Runtime on the standard CPU. In addition, SafeLOGIC-X products have the same I/O properties as the associated SafeIO products (X20SIx1x0).
- Available
-
- X20cSO2530
- This module is equipped with 2 safe relay outputs. The module can be used for controlling floating actuators in safety-related applications up to PL e or SIL 3. Safety relays are installed in the module. The positively driven feedback contacts are evaluated internally by the module. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.
- Available
-
- X20cSO4110
- This module is equipped with 4 safe digital outputs. The nominal output current is 0.5 A. The module can be used for controlling actuators in safety-related applications up to PL e or SIL 3. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side low-side" variant (output type A) is limited to actuators without reference potential (e.g. relays, valves). Type A outputs have safety-related advantages since the actuator can be cut off in its connection cable in all error scenarios. Safe digital output channels provide protection against automatic restart when network errors occur and also using a current measurement for open circuit detection. This module is designed for X20 12-pin terminal blocks.
- Available
-
- X20cSO4120
- This module is equipped with 4 safe digital outputs. The nominal output current is 2 A. The module can be used for controlling actuators in safety-related applications up to PL e or SIL 3. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side low-side" variant (output type A) is limited to actuators without reference potential (e.g. relays, valves). Type A outputs have safety-related advantages since the actuator can be cut off in its connection cable in all error scenarios. Safe digital output channels provide protection against automatic restart when network errors occur and also using a current measurement for open circuit detection. This module is designed for X20 12-pin terminal blocks.
- Available
-
- X20cSO6300
- This module is equipped with 6 safe digital outputs. The nominal output current is 0.2 A. The module can be used for controlling actuators in safety-related applications up to PL e or SIL 3. The outputs are designed using semiconductor technology so that the safety-related characteristics do not depend on the number of operating cycles. The "high-side high-side" variant (output type B) is required for actuators with reference potential (e.g. Enable inputs on frequency inverters). It is important to observe the special notices for the cabling in this case. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.
- Available
-
- X20cSO6530
- This module is equipped with 6 safe relay outputs. The module can be used for controlling floating actuators in safety-related applications up to PL e or SIL 3. Safety relays are installed in the module. The positively driven feedback contacts are evaluated internally by the module. Safe digital output channels provide protection against automatic restart when network errors occur. This module is designed for X20 12-pin terminal blocks.
- Available