- NF125-SVU2P70A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 2-poles (2P), Rated current 70A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU2P75A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 2-poles (2P), Rated current 75A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU2P80A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 2-poles (2P), Rated current 80A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU2P90A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 2-poles (2P), Rated current 90A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P100A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 100A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P100AS
- Moulded / Molded Case Circuit Breaker (MCCB) with lug kit, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 100A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P125A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 125A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P125A1
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed 120Vac shunt trip coil, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 125A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection, Coil control voltage 120Vac
- Available
-
- NF125-SVU3P125AS
- Moulded / Molded Case Circuit Breaker (MCCB) with lug kit, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 125A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P15A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 15A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P15AA
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed auxiliary switch, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 15A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P15AS
- Moulded / Molded Case Circuit Breaker (MCCB) with lug kit, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 15A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P20A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 20A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P20AS
- Moulded / Molded Case Circuit Breaker (MCCB) with lug kit, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 20A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P20AU2
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed 200Vac-250Vac undervoltage trip coil (non-reset type), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 20A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P20AU24
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed 24Vac/dc undervoltage trip coil (non-reset type), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 20A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P20AY
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed auxiliary switch + vertical lead-wire terminal block, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 20A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P30A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 30A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P30A1
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed 120Vac shunt trip coil, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 30A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection, Coil control voltage 120Vac
- Available
-
- NF125-SVU3P30AD3
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 30A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P30AS
- Moulded / Molded Case Circuit Breaker (MCCB) with lug kit, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 30A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P30AU2
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed 200Vac-250Vac undervoltage trip coil (non-reset type), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 30A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P30AU24
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed 24Vac/dc undervoltage trip coil (non-reset type), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 30A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P30AY
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed auxiliary switch + vertical lead-wire terminal block, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 30A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P40A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 40A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available