- Part Number
- Description
- Availability
-
- NF125-SVU3P40A1
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed 120Vac shunt trip coil, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 40A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection, Coil control voltage 120Vac
- Available
-
- NF125-SVU3P40AS
- Moulded / Molded Case Circuit Breaker (MCCB) with lug kit, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 40A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P40AU2
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed 200Vac-250Vac undervoltage trip coil (non-reset type), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 40A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P40AU24
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed 24Vac/dc undervoltage trip coil (non-reset type), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 40A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P50A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 50A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P50A1
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed 120Vac shunt trip coil, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 50A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection, Coil control voltage 120Vac
- Available
-
- NF125-SVU3P50AS
- Moulded / Molded Case Circuit Breaker (MCCB) with lug kit, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 50A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P50AY
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed auxiliary switch + vertical lead-wire terminal block, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 50A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P60A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 60A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P60AS
- Moulded / Molded Case Circuit Breaker (MCCB) with lug kit, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 60A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P60AY
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed auxiliary switch + vertical lead-wire terminal block, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 60A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P70A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 70A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P70AS
- Moulded / Molded Case Circuit Breaker (MCCB) with lug kit, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 70A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P75A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 75A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P75A1
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed 120Vac shunt trip coil, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 75A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection, Coil control voltage 120Vac
- Available
-
- NF125-SVU3P75AS
- Moulded / Molded Case Circuit Breaker (MCCB) with lug kit, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 75A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P75AY
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed auxiliary switch + vertical lead-wire terminal block, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 75A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P80A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 80A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P80A1
- Moulded / Molded Case Circuit Breaker (MCCB) with pre-installed 120Vac shunt trip coil, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 80A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection, Coil control voltage 120Vac
- Available
-
- NF125-SVU3P80AS
- Moulded / Molded Case Circuit Breaker (MCCB) with lug kit, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 80A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P90A
- Moulded / Molded Case Circuit Breaker (MCCB), UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 90A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SVU3P90AS
- Moulded / Molded Case Circuit Breaker (MCCB) with lug kit, UL 489 Listed MCCBs, NF-S (standard class), 3-poles (3P), Rated current 90A, Short circuit breaking capacity (Icu) 30kA (400Vac; IEC60947), Short circuit current rating 30kA (480Vac; UL489), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
-
- NF125-SW 3P 20A
- (NF125SW3P20A) no-fuse circuit breaker, 3P, 20A.
- Available
-
- NF125-SW 3P 50A
- (NF125SW3P50A) no-fuse circuit breaker, 3P, 50A.
- Available
-
- NF125-UV2P100A
- Moulded / Molded Case Circuit Breaker (MCCB), WS-V series, NF-U (ultra current-limiting class), 2-poles (2P), Rated current 100A, Short circuit breaking capacity (Icu) 200kA (400Vac; IEC60947), Thermal-Magnetic (fixed) trip unit, Front lugs or bars connection connection
- Available
Trusted by…