- Part Number
- Description
- Availability
-
- 7SJ8041-5EB96-3FC3 L0R
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC 61850, 100MBIT ETHERNET, ELECTR., DOUBLE, RJ45 CONNECTOR INTERFACE, PORT A (ON BOTTOM OF DEVICE) WITH ETHERNET INTERFACE (DIGSI, NOT IEC61850) RJ45 CONNECTOR METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP, TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITIONAL FUNCTIONS: DRIECTIONAL PHASE & GROUND OVERCURRENT DIRECT. SENSITIVE GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITH AUTOMATIC RECLOSING AND FAULT LOCATOR
- Available
-
- 7SJ8041-5EB96-3FC3-Z
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT
- Available
-
- 7SJ8041-5EC90-3FB0-L0S
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION US, ANSI, LANGUAGE US-ENGL (LANGUAGE CHANGEABLE) US-FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC 61850, 100MBIT ETHERNET, WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR NO SYSTEM PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
- Available
-
- 7SJ8041-5EE06-3FB0
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI LANGUAGE SPANISH (LANGUAGE CHANGEABLE) STANDARD FRONT NO SYSTEM PORT INTERFACE, PORT A (ON BOTTOM OF DEVICE) WITH ETHERNET INTERFACE (DIGSI, NOT IEC61850) RJ45 CONNECTOR METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
- Available
-
- 7SJ8041-5EE90-3FC0
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT
- Available
-
- 7SJ8041-5EE96-3FB0
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT
- Available
-
- 7SJ8041-5EE96-3FC0
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT
- Available
-
- 7SJ8042-5ED20-1FB1
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 7 BI, 8 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION FR, IEC/ANSI LANGUAGE FRENCH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC60870-5-103 O. DIGSI4/MODEM ELECTRICAL RS-485 NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITH AUTOMATIC RECLOSING
- Available
-
- 7SJ8071-1EB90-1FA0 L0S
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE: DC 24, 48V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC 61850, 100MBIT ETHERNET, WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP, TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>. IEE>>, IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
- Available
-
- 7SJ8071-5EB90-1FA0 L0D
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) MODBUS, ELECTRICAL RS-485 NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP, TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>. IEE>>, IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
- Available
-
- 7SJ8071-5EB90-1FA0-L0A
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) PROFIBUS DP SLAVE, ELECTRICAL RS-485 NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP, TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>. IEE>>, IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
- Available
-
- 7SJ8071-5EB90-3FA0-L0A
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) PROFIBUS DP SLAVE, ELECTRICAL RS-485 NO SYSTEM PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP, TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>. IEE>>, IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
- Available
-
- 7SJ8072-5EB90-1FA0-L0A
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) PROFIBUS DP SLAVE, ELECTRICAL RS-485 NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP, TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>. IEE>>, IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) PARAMETER CHANGEOVER MONITORING FUNCTIONS CONTROL OF CIRCUIT BREAKER FLEXIBLE PROTECTION FUNCTIONS (CURRENT PARAMETERS) INRUSH RESTRAINT WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
- Available
-
- 7SJ8081-1EB90-3FC1-Z
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT
- Available
-
- 7SJ8081-5EB90-1FA0-L0S
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC 61850, 100MBIT ETHERNET, WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR NO SYSTEM PORT A METERING: FAULT RECORDING WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
- Available
-
- 7SJ8081-5EB90-1FB0 L0D
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) MODBUS, ELECTRICAL RS-485 NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
- Available
-
- 7SJ8081-5EB90-1FB0 L0S
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) IEC 61850, 100MBIT ETHERNET, WITH INTEGRATED SWITCH OPTICAL, DOUBLE, LC-CONNECTOR NO SYSTEM PORT A METERING: FAULT RECORDING FUNKTIONALITY: TOC PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP, OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITONAL FUNCTIONS: DIRECTIONAL GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
- Available
-
- 7SJ8081-5EB90-1FQ0 L0D
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IE = 1A/5A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) MODBUS, ELECTRICAL RS-485 NO SYSTEM PORT A METERING: FAULT RECORDING FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP, TIME OVERCURRENT PROTECTION GROUND (50N/51N) : IE>, IE>>, I>>>, IEP, GROUND FAULT PROTECTION IEE>, IEE>>, IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCY PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITIONAL FUNCTIONS: DIRECTIONAL PHASE OVERCURRENT VOLTAGE A. FREQUENCY PROTECTION SYNCHRO-CHECK FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
- Available
-
- 7SJ8081-5EB90-3FC1-Z
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT
- Available
-
- 7SJ8082-5EB90-3FC0-L0A
- OVERCURRENT PROTECTION RELAY HOUSING 1/6 19", 4 X I, 3 X U, 11 BI, 5 BO, (2 CHANGEOVER) 1 LIVE STATUS CONTACT MEASURING INPUTS: IPH = 1A/5A, IEE (SENSITIVE) = 0,001 TO 1,6 A/0,005 TO 8A RATED AUXILIARY VOLTAGE DC 60V/110V/125V/220V, AC 115V/230V FLUSH-MOUNTING CASE, SCREW-TYPE TERMINAL REGION WORLD, IEC/ANSI, LANGUAGE ENGLISH (LANGUAGE CHANGEABLE) STANDARD FRONT SYSTEM PORT, PORT B (ON BOTTOM OF DEVICE, REAR) PROFIBUS DP SLAVE, ELECTRICAL RS-485 NO SYSTEM PORT A METERING: FAULT RECORDING, AVERAGE VALUES, MIN/MAX VALUES FUNCTIONALITY: TOC+ PHASE OVERCURRENT (50/51) I>, I>>, I>>>, IP, TIME OVERCURRENT PROTECTION GROUND 50N/51N, IE>, IE>>, IE>>>, IEP GROUND FAULT PROTECTION IEE>, IEE>>, IEEP OVERLOAD PROTECTION (49) TRIP CIRCUIT SUPERVISION (74TC) CIRCUIT BREAKER FAILURE PROTECT NEGATIVE SEQUENCE PROTECTION UNDERCURRENT MONITORING (37) LOCK OUT (86) ADDITIONAL FUNCTIONS: DRIECTIONAL PHASE & GROUND OVERCURRENT DIRECT. SENSITIVE GROUND FAULT VOLTAGE A. FREQUENCY PROTECTION FLEXIBLE PROTECTION FUNCTIONS (CURRENT AND VOLTAGE PARAMET.) WITHOUT AUTO-RECLOSURE WITHOUT FAULT LOCATOR
- Available
-
- 7SK8012-5EB90-1HD0 L0A
- Motor protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BO (2 changeover contacts) 1 live contact Measuring inputs: Iph = 1 A/5 A, Iee (sensitive) = 0.001 to 1.6 A/0.005 to 8 A Rated auxiliary power: 60 V/110 V/125 V/220 V DC, 115 V/230 V AC Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) PROFIBUS DP slave, electric RS-485 Without system interface, Port A Measurement: fault recording Functionality: XMZ+ Overcurrent time sw. XMZ PH (50/51) I>, I>>, I>>>, Ip Ground fault protection XMZ GROUND (50N/51N: Ie>, Ie>>, Ie>>>, Iep Ground fault/Ground short circuit protection Iee>. Iee>>, Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Motor statistics Parameter set switchover Monitoring functions
- Available
-
- 7SK8021-5EB20-1HD0
- Motor protection Enclosure 1/6 19", 4 x I, 7 BI, 8 BO (2 changeover contacts) 1 live contact Measuring inputs: Iph = 1 A/5 A, Ie = 1 A/5 A Rated auxiliary power: 60 V/110 V/125 V/220 V DC, 115 V/230 V AC Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) IEC60870-5-103 or DIGSI4/modem, electrical RS 485 Without system interface, Port A Measurement: fault recording Functionality: XMZ+ Overcurrent time sw. XMZ PH (50/51) I>, I>>, I>>>, Ip Ground fault protection XMZ GROUND (50N/51N: Ie>, Ie>>, Ie>>>, Iep Ground fault/Ground short circuit protection Iee>. Iee>>, Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Motor statistics Parameter set switchover Monitoring functions
- Available
-
- 7SK8041-5EB96-3HE0-Z
- Motor protection Enclosure 1/6 19", 4 x I, 3 x U, 7 BI, 8 BO (2 changeover contacts) 1 live contact
- Available
-
- 7SK8042-5EB90-3HE0-L0A
- Motor protection Enclosure 1/6 19", 4 x I, 3 x U, 7 BI, 8 BO (2 changeover contacts) 1 live contact Measuring inputs: Iph = 1 A/5 A, Iee (sensitive) = 0.001 to 1.6 A/0.005 to 8 A Rated auxiliary power: 60 V/110 V/125 V/220 V DC, 115 V/230 V AC Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) PROFIBUS DP slave, electric RS-485 Without system interface, Port A Measurement: fault recording Mean value formation, min./max. values Functionality: XMZ Overcurrent time sw. XMZ PH (50/51) I>, I>>, I>>>, Ip Ground fault protection XMZ GROUND (50N/51N) Ie>, Ie>>, Ie>>>, Iep Ground fault/Ground short circuit protection Iee>, Iee>>, Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Supplementary function: Ground fault direction detection (*)
- Available
-
- 7SK8042-5EB96-1HE0-Z
- Motor protection Enclosure 1/6 19", 4 x I, 3 x U, 7 BI, 8 BO (2 changeover contacts) 1 live contact
- Available