- Part Number
- Description
- Availability
-
- 7SK8042-5EB96-3HE0
- Motor protection Enclosure 1/6 19", 4 x I, 3 x U, 7 BI, 8 BO (2 changeover contacts) 1 live contact
- Available
-
- 7SK8042-5EB96-3HE0-L0A
- Motor protection Enclosure 1/6 19", 4 x I, 3 x U, 7 BI, 8 BO (2 changeover contacts) 1 live contact Measuring inputs: Iph = 1 A/5 A, Iee (sensitive) = 0.001 to 1.6 A/0.005 to 8 A Rated auxiliary power: 60 V/110 V/125 V/220 V DC, 115 V/230 V AC Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) PROFIBUS DP slave, electric RS-485 Interface, Port A (device underside, front) With Ethernet interface (DIGSI interface, thermobox connection, not IEC61850) RJ45 connector Measurement: fault recording Mean value formation, min./max. values Functionality: XMZ Overcurrent time sw. XMZ PH (50/51) I>, I>>, I>>>, Ip Ground fault protection XMZ GROUND (50N/51N) Ie>, Ie>>, Ie>>>, Iep Ground fault/Ground short circuit protection Iee>, Iee>>, Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Supplementary function: Ground fault direction detection (*)
- Available
-
- 7SK8052-5EB90-3HD0-L0D
- Motor protection Enclosure 1/6 19", 4 x I, 3 BI, 5 BO (2 changeover contacts) 5 temperature sensors 1 live contact Measuring inputs: Iph = 1 A/5 A, Iee (sensitive) = 0.001 to 1.6 A/0.005 to 8 A Rated auxiliary power: 60 V/110 V/125 V/220 V DC, 115 V/230 V AC Installation enclosure Screw terminals Region world, IEC/ANSI English (language can be changed) Front membrane standard System interface port B (device underside, rear) Modbus, electrical RS 485 Without system interface, Port A Measurement: fault recording Mean value formation, min./max. values Functionality: XMZ+ Overcurrent time sw. XMZ PH (50/51) I>, I>>, I>>>, Ip Ground fault protection XMZ GROUND (50N/51N: Ie>, Ie>>, Ie>>>, Iep Ground fault/Ground short circuit protection Iee>. Iee>>, Ieep Overload protection (49) Trip circuit monitoring (74TC) Circuit breaker failure protection (50BF), Load unbalance protection (46) Lock out (86) Start up time monitoring (48) Undercurrent monitoring (37) Reclosing lockout (66/86) Rotor blocking protection (14) Load step protection (51M) Motor statistics Parameter set switchover Monitoring functions
- Available
-
- 7SR1003-1LA20-2CA0
- Overcurrent Relay, 1/5a Input, 50/60hz, 60-240vac/dc, Size 4 Molded Casing, 4 Ct, 10 Led
- Available
-
- 7SR1101-1JA12-1CA0
- ARGUS-C NON DIRECT. OVERCURRENT RELAY 1 CT, 10 LEDS, 3 BINARY INPUTS/5 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ 24 to 60 V DC auxiliary, binary input threshold 19 V DC. USB FRONT PORT, RS-485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT COVER: NO PUSH BUTTONS PROTECTION FUNCTION: STANDARD VERSION
- Available
-
- 7SR1101-3JA12-1CA0
- Overcurrent Relay, Argus-c Non Direct, 1ct, 10leds, 3binary Input/5binary Output, Measuring Input 1/5a, 50/60hz, With Sef Input 24-60V dc Auxiliary, Binary Input Threshold 19vdc
- Available
-
- 7SR1102-1JA12-1CA0
- ARGUS-C NON DIRECT. OVERCURRENT RELAY 4 CT, 10 LEDS, 3 BINARY INPUTS/5 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ 24 to 60 V DC auxiliary, binary input threshold 19 V DC. USB FRONT PORT, RS-485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT COVER: NO PUSH BUTTONS PROTECTION FUNCTION: STANDARD VERSION
- Available
-
- 7SR1102-1JA12-2CA0
- Argus-c Non Direct. Over Current Relay 4 Ct, 10 Leds, 3 Binary Inputs/5 Binary Outp.
- Available
-
- 7SR1103-1MA12-1CA0
- ARGUS-C NON DIRECT. OVERCURRENT RELAY 4 CT, 10 LEDS, 6 BINARY INPUTS/8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 24 TO 250V DC, 100 TO 230V AC, BINARY INPUT THRESHOLD 19V DC. USB FRONT PORT, RS-485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT COVER: NO PUSH BUTTONS PROTECTION FUNCTION: STANDARD VERSION
- Available
-
- 7SR1103-3HA87-2CA0
- Overcurrent Relay, Argus-c Non Direct, 4ct, 10leds, 6binary Inp, 8binary Out, Usbe Frt Port, 80, 250v Sef Input, 50/60 Hz
- Available
-
- 7SR1206-2MA12-1CA0
- ARGUS-C DIRECTIONAL OVERCURRENT RELAY 4 CT, 3 VT, 10 LEDS, 6 BINARY INPUTS/8 BINARY OUTP. MEASURING INPUT: 1/5A, 40 to 160V, 50/60HZ DC, 100 TO 230V AC, BINARY INPUT THRESHOLD 19V DC. USB FRONT PORT, RS-485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT COVER: NO PUSH BUTTONS PROTECTION FUNCTION: STANDARD VERSION
- Available
-
- 7SR1208-4NA12-2CA0
- ARGUS-C DIRECTIONAL OVERCURRENT RELAY 4 CT, 3 VT, 10 LEDS, 4 BINARY INPUTS/8 BINARY OUTP. MEASURING INPUT: 1/5A,40 to 160V, 50/60HZ WITH SEF INPUT DC, 100 TO 230V AC, BINARY INPUT THRESHOLD 88V DC. USB FRONT PORT, RS-485 REAR PORT (E4 CASE) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) FRONT COVER: PUSH BUTTONS, DOWN AND RIGHT ARROWS PROTECTION FUNCTION: STANDARD VERSION
- Available
-
- 7SR1703-3MA87-1CA0
- MOTOR PROTECTION RELAY (RHO) CT, 6 BINARY INPUTS/8 BINARY OUTPUTS, 10 LEDs MEASURING INPUT: 1/5A, 50/60HZWITH SEF INPUT Auxiliary voltage: 24 to 250 V DC, 100 to 230 V AC, binary input threshold 19 V DC. REAR OPTICAL ETHERNET DUPLEX (E6 CASE iIS REQUIRED) PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 AND IEC 61850 OR MODBUS RTD CLIENT (USER SELECTABLE SETTING) FRONT COVER: NO PUSH BUTTONS PROTECTION FUNCTION: STANDARD VERSION
- Available
-
- 7SR2203-2MA87-0CA0
- Argus-M Directional time-overcurrent protection E8 enclosure, 5 curr. trans., 4 volt. trans.,13 BI/14 BO,16 LEDs Measuring inputs: 1/5A, 63.5/110V, 50/60Hz Auxiliary voltage 24, 250V DC/100- 230V AC Threshold binary input: 19V DC USB interface at front, RS-485 interface at rear, + opt. Ethernet Duplex at rear Protocol: IEC 60870-5-103 and Modbus RTU and DNP 3.0 (adjustable) and IEC 61850 Protective function: Standard version
- Available
-
- 7SR2242-2AC88-0CA0
- Overcurrent Relay, 8 Leds, 14 Binary Output, USB Front Port, 50/60 Hz
- Available
-
- 7SR2242-2MC88-0CA0
- Overcurrent Relay, 8 Leds, 14 Binary Output, 24-250V dc, 100-230vac
- Available
-
- 7SR2302-1MA77-0CA0
- HIGH IMPEDANCE PROTECTION RELAY CIRCULATING CURRENT (4 POLE FUNCTIONALITY) E6 CASE, 4 CT, 8 LEDS, 9 BINARY INPUTS/8 BINARY OUTP. MEASURING INPUT: 1/5A, 50/60HZ AUXILIARY VOLTAGE: 24, 250V DC/100-230V AC BINARY INPUT THRESHOLD 19V DC (RATED: 24-250V DC). USB FRONT PORT, RS-485 REAR PORT + REAR ELECTRICAL ETHERNET RJ45 PROTOCOL: IEC 60870-5-103 AND MODBUS RTU AND DNP 3.0 (USER SELECTABLE SETTING) AND IEC61850. PROTECTION FUNCTION: 3 PHASE HIGH IMPEDANCE DIFFERENTIAL (87/50) HIGH IMPEDANCE RESTRICTED EARTH FAULT (87REF) MEASURED EARTH FAULT (50G) 3 PHASE CT SUPERVISION (CT50) TRIP CIRCUIT SUPERVISIOR (74TC) PROGRAMMABLE LOGIC..
- Available
-
- 7SR2423-2MA11-0AA0
- Duobias-m Transformer Differential Relay (2 Winding) E10 Case 24-250V dc
- Available
-
- 7SR4501-1GA10-1AA0
- ARGUS Non-directional overcurrent-time protection Polycarbonate enclosure, 4x current transformer, 2 BI/2 BQ, pulse output, 9 LEDs Measuring input: 1 A, 50/60Hz Auxiliary voltage: current transformer supplied USB front interface No protocol (no interface on the rear) Device front: standard version Protection function package: basic version
- Available
-
- 7SR5111-7AA16-0AA0
- Directional time-overcurrent protection 7SR51 4 curr. trans., 4 volt. trans., 39 BI, 20 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure
- Available
-
- 7SR5421-1AA16-0AA0
- Transformer protection (2 wdg.) 8 curr. trans., 4 volt. trans. 12 BI, 8 BO Standard interface: 1 x USB (front), RS 485 (rear) + 2 x RJ45 interfaces S12 enclosure
- Available
-
- 7SX8000-3AA50-1CA0
- 7SX800 universal protection device; with basic functionality; function extension through additionally orderable function points; BI: 4; BO: 5 (4 fast, 1 life) I: 4 (4 x protection) U: 4 (standard) housing: 1/6 x 19"; 8 LEDs; 9 function keys; Ethernet: optical; serial interface; operation panel: integrated; display type: color display; front design: standard; auxiliary voltage: 24 V, 250 V DC, 115 V, 230 V AC
- Available
-
- 7TM7000-0AA00-0AA0
- STABILIZING/COMMAND OUTPUT MODULE FOR CENTEALISED BUSBAR PROTECTION 7SS60 5 STABILIZING CTS, 5 RELAYS WITH 2 NO CONTACTS AUXILIARY VOLTAGE: DC 48/60V, 110/125V, 220/250V SETTABLE
- Available
-
- 7TS1632-0AA00-1
- Signal relay with 4 LED displays and reset push button Auxiliary voltage: 110/125 V DC Relay with base 7XP9010-2 for flush-mounting
- Available
-
- 7TS2711-2/FH
- Teleperm module.
- Available
Trusted by…
Trusted by industry leaders
Trusted by industry leaders